Paper
8 October 1992 SIXA spectrometer on SPECTRUM-X-GAMMA satellite
Veikko J. Kamarainen, Heikki Sipila, Ivor Taylor, Osmi R. Vilhu, J. Huovelin, Jouko A. Kurki, Erik Laegsgaard, Rashid Sunyaev
Author Affiliations +
Abstract
The major telescopes on board the SPECTRUM-X-GAMMA satellite are two SODART X-ray telescopes with 8 m focal lengths. One of them includes the Finnish experiment SIXA (Silicon X-ray Array detector) as one of its focal plane instruments. SIXA's main task will be the measurement of X-ray spectra with good resolution. The SIXA detector capsule consists of 19 discrete, circular, and closely packed lithium drifted silicon detector elements. A passive cooling system on the satellite provides 110 - 120 K operating temperature for the detector. Special attention has been paid to reducing detector leakage currents in order to achieve the desired resolution of 170 - 180 eV at 6 keV for 50 mm2 active area detector elements within the temperature range of the cooler. In a parallel study, fabrication of 19 separate measuring pixels on a single lithium drifted silicon wafer is being investigated. The analog electronics section consists of 19 parallel amplifier channels. Two microprocessors are used to provide up to four simultaneous measurement modes for different scientific purposes. Use of hard disk drives in hermetically sealed containers as mass memory is under study. This paper gives an updated description of the SIXA spectrometer concept.
© (1992) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Veikko J. Kamarainen, Heikki Sipila, Ivor Taylor, Osmi R. Vilhu, J. Huovelin, Jouko A. Kurki, Erik Laegsgaard, and Rashid Sunyaev "SIXA spectrometer on SPECTRUM-X-GAMMA satellite", Proc. SPIE 1743, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy III, (8 October 1992); https://doi.org/10.1117/12.130679
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

X-rays

X-ray astronomy

X-ray telescopes

Satellites

X-ray detectors

Silicon

RELATED CONTENT

Dead-time effects in microchannel-plate imaging detectors
Proceedings of SPIE (October 01 1991)
Silicon x-ray array detector on spectrum-x-gamma satellite
Proceedings of SPIE (October 01 1991)
High angular resolution hard x ray imager for the high...
Proceedings of SPIE (November 01 1990)
Astro E2 mission the third X ray observatory in...
Proceedings of SPIE (March 11 2003)
Development of a silicon drift detector array an x...
Proceedings of SPIE (September 03 2009)

Back to Top