Paper
27 March 1984 The Infrared Emittance Of Semi-Transparent Materials Measured At Cold Temperatures
S J Marshall
Author Affiliations +
Abstract
The infrared emittance of semi-transparent glazing materials used in passive solar building construction was measured over the temperature range -5.6°C to +15°C at 2 - 5.6 μm wavelength. A table of measured apparent emittance values is presented. Absolute values of emittance are not provided due to the conclusion that no adequate model describing three-dimensional emittance in terms of thickness, rectilinear transmittance, and broadband detector sensitivity has yet been formulated. A rough rule-of-thumb for thermographers appears to be that a high emittance value can be assumed for most thick sheets of these materials but the emittance of thin films drops rapidly below a certain critical thickness.
© (1984) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
S J Marshall "The Infrared Emittance Of Semi-Transparent Materials Measured At Cold Temperatures", Proc. SPIE 0446, Thermosense VI: Thermal Infrared Sensing for Diagnostics and Control, (27 March 1984); https://doi.org/10.1117/12.939160