3 February 2017 Handheld chemiresistive gas sensor readout system
Trudi-Heleen Joubert, Jurie du Toit, Bonex Mkwakikunga, Peter Bosscha
Author Affiliations +
Proceedings Volume 10036, Fourth Conference on Sensors, MEMS, and Electro-Optic Systems; 100360R (2017) https://doi.org/10.1117/12.2245787
Event: Fourth Conference on Sensors, MEMS and Electro-Optic Systems, 2016, Skukuza, Kruger National Park, South Africa
Abstract
Low-cost and non-invasive diabetes diagnosis is increasingly important [1], and this paper presents a handheld readout system for chemiresistive gas sensors in a breath acetone diagnostic application.

The sensor contains reference and detection devices, used for the detection of gas concentration. Fabrication is by dropcasting a metaloxide nanowire solution onto gold interdigitated electrodes, which had been manufactured on silicon. The resulting layer is a wide bandgap n-type semiconductor material sensitive to acetone, producing a change in resistance between the electrode terminals [2]. Chemiresistive sensors typically require temperatures of 300-500 °C, while variation of sensing temperature is also employed for selective gas detection. The nano-structured functional material requires low temperatures due to large surface area, but heating is still required for acceptable recovery kinetics. Furthermore, UV illumination improves the sensor recovery [3], and is implemented in this system. Sensor resistances range from 100 Ω to 50 MΩ, while the sensor response time require a sampling frequency of 10Hz.

Sensor resistance depends on temperature, humidity, and barometric pressure. The GE CC2A23 temperature sensor is used over a range of -10°C to 60°C, the Honeywell HIH5031 humidity sensor operates up to 85% over this temperature range, and the LPS331AP barometric pressure sensor measures up to 1.25 bar. Honeywell AWM43300V air flow sensors monitor the flow rate up to 1000 sccm. An LCD screen displays all the sensor data, as well as real time date and time, while all measurements are also logged in CSV-format. The system operates from a rechargeable battery.
© (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Trudi-Heleen Joubert, Jurie du Toit, Bonex Mkwakikunga, and Peter Bosscha "Handheld chemiresistive gas sensor readout system", Proc. SPIE 10036, Fourth Conference on Sensors, MEMS, and Electro-Optic Systems, 100360R (3 February 2017); https://doi.org/10.1117/12.2245787
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Nanosensors

Electrodes

Gas sensors

Integrated circuits

Glucose

Blood

Back to Top