Paper
1 May 1989 Instrument Design Case Study Flexure Thermal Sensitivity And Wafer Stepper Baseline Drift
Stanley W. Stone
Author Affiliations +
Proceedings Volume 1036, Precision Instrument Design; (1989) https://doi.org/10.1117/12.950961
Event: SPIE Advanced Processing Technologies for Optical and Electronic Devices (colocated wth OPTCON), 1988, Santa Clara, CA, United States
Abstract
Optical wafer steppers are extremely precise instruments with some very stringent demands placed upon them. They include three-shift production operation, submicron resolution and overlay and high wafer throughput. Registration, a component of overlay, is dependent on the stability of the alignment system and its relationship to the optical axis of the reduction lens. Baseline, the distance between the alignment system and the optical axis, must be stable to for proper operation of the system. Baseline stability in the DSW Wafer Stepper® system has been a issue for a very long time. A large component of this drift has been traced to a high thermal sensitivity of a flexure in the focus motion actuator. This thermal sensitivity, coupled with the Abbe offset in the alignment microscope and the proximity of the voice coil motor to the flexure, causes a rotation of the optical column. Because of the Abbe offset, this rotation causes a shift in the baseline, which has been previously attributed to other unrelated items. Remedies for this problem are quite simple once the phenomenon is understood. They include: proper setup of the instrument to minimize the heat generated at the voice coil motor; thermal isolation of the flexure from the voice coil motor with low thermal conductivity materials; redesign of the voice coil motor for higher efficiency; and active control of the motor temperature. Later designs of the focus motion assembly eliminate the baseline drift problem through the use of high efficiency motors and mechanical design symmetry.
© (1989) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Stanley W. Stone "Instrument Design Case Study Flexure Thermal Sensitivity And Wafer Stepper Baseline Drift", Proc. SPIE 1036, Precision Instrument Design, (1 May 1989); https://doi.org/10.1117/12.950961
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Semiconducting wafers

Optical alignment

Microscopes

Wafer-level optics

Interferometers

Zirconium

Bridges

Back to Top