6 July 2018 Upgrade of the CFHT closed-cycle cooling heat-rejection process
Ivan Look, Chas Cavedoni, Grant Matsushige, Tom Vermeulen, Casey Elizares, Steve Bauman
Author Affiliations +
Abstract
CFHT currently removes heat from the Closed-Cycle Cold Heads of the telescope prime focus instruments, MegaPrime (Wide-Field Optical Imager) and WIRCam (Wide-Field Infrared Camera) by using water-cooled Helium Compressors which provide gas transfer characteristics allowing the dewars to achieve Cryogenic Temperatures. In addition, CFHT uses air-cooled Compressor Units to provide Closed-Cycle cooling for their telescope Cassegrain instrument, SITELLE (Optical imaging Fourier transform spectrometer). With the addition of a new instrument at the end of 2017, SPIRou (near-infrared spectropolarimeter); an upgrade to the Closed-Cycle cooling system was required to remove the extra 10 kW of heat. Therefore the decision to design and develop a more efficient and less complicated cooling system was pursued. The initial concepts were incorporated from Chas Cavedoni of the GEMINI Observatory, the master mind behind their ambient air cooling system. The cool ambient temperatures experienced year round on Mauna Kea (+4° C to +21° C), coupled with the relatively warm (+10° C to +32° C) cooling water required by the Helium Compressor Units; lends itself to a much simpler and less expensive Fluid-Cooling system which essentially utilizes a glorified Radiator (Heat Exchanger). This paper shall describe the Design Considerations, System Design, and System Performance of this new cooling method and share the lessons learned from this innovative concept. This new design will not only provide cooling for the additional 10 kW introduced by SPIRou, but also handle the existing 10 kW (MegaPrime and WIRCam) currently being removed by stand-alone Refrigeration Chillers. An additional 10kW capacity has been incorporated into the new system to provide cooling for future expansion, which ultimately results in a Fluid Cooling System capable of removing a 30 kW heat load.
© (2018) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ivan Look, Chas Cavedoni, Grant Matsushige, Tom Vermeulen, Casey Elizares, and Steve Bauman "Upgrade of the CFHT closed-cycle cooling heat-rejection process", Proc. SPIE 10700, Ground-based and Airborne Telescopes VII, 107002U (6 July 2018); https://doi.org/10.1117/12.2311409
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cooling systems

Helium

Water

Observatories

Switching

Circuit switching

Telescopes

RELATED CONTENT

Development of a cold chopper for TAO/MIMIZUKU
Proceedings of SPIE (December 13 2020)
Spitzer scheduling challenges: cold and warm
Proceedings of SPIE (July 12 2008)
Environmental factors affecting solar seeing
Proceedings of SPIE (February 11 2003)
European Solar Telescope (EST) transfer optics
Proceedings of SPIE (August 05 2010)

Back to Top