The paper outlines the instruments vacuum and cryogenic requirements, gives a brief overview of the ESO vacuum and cryogenic standards, and of the ELT cryogenic infrastructure baseline concept. The current testing approach for selected standard components such as low-vibration cryo-coolers and vibration damping systems will be presented. |
|