13 May 2019 Evaluation of 7-degree-of-freedom robotic arm precision and effects of calibration methods
Arnon Hurwitz, Marshal Childers, Kristi Davis, Michael DiBlasi, Jim Dotterweich, Matt Kaplan, Chad Kessens, Trevor Rocks
Author Affiliations +
Abstract
This paper presents results from an experiment performed at the Combat Capabilities Development Command, Army Research Laboratory, Autonomous Systems Division (ASD) on the precision of a 7-degree-of-freedom robotic manipulator used on the RoMan robotic platform. We quantified the imprecision in the arm end-effector final position after arm movements ranging over distances from 362 mm to 1300 mm. In theory, for open-loop grasping, one should be able to compute the final X-Y-Z position of the gripper using forward kinematics. In practice, uncertainty in the arm calibration induces uncertainty in the forward kinematics so that it is desirable to measure this imprecision after different arm calibrations. Forty-one runs were performed under different calibration regimes. Ground truth was provided by measuring arm motions with a Vicon motion capture system while the chassis of the platform remained stationary during the experiment. Using a digital protractor to align the arm joints to the ground plane for a “Level” type calibration, the average total offset of the gripper in 3D space was 19.6 mm with a maximum of about 30 mm. After a “Field” (i.e. Hand-Eye) calibration, which aligned fiducials on the joints, the average total offset came to 37.8 mm with a maximum of about 80 mm. Distance travelled by the arm was found to be uncorrelated with total offset. The experiment demonstrated that Total (X, Y, Z) Offset in the gripper final position is reduced significantly if the robot arm is first calibrated using a standard “Level” calibration. The “Field” calibration method results in a significant increase in Offset variation.
Conference Presentation
© (2019) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Arnon Hurwitz, Marshal Childers, Kristi Davis, Michael DiBlasi, Jim Dotterweich, Matt Kaplan, Chad Kessens, and Trevor Rocks "Evaluation of 7-degree-of-freedom robotic arm precision and effects of calibration methods", Proc. SPIE 11021, Unmanned Systems Technology XXI, 110210E (13 May 2019); https://doi.org/10.1117/12.2518630
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Robotics

Kinematics

Analytical research

Sensors

Algorithm development

Distance measurement

RELATED CONTENT

Vehicle localization on gravity maps
Proceedings of SPIE (July 22 1999)
Computer-aided programming of automated welding work cells
Proceedings of SPIE (November 09 1994)
Reconfigurable robots for all-terrain exploration
Proceedings of SPIE (October 16 2000)
Updating Distance Maps When Objects Move
Proceedings of SPIE (January 01 1987)

Back to Top