Volumetric defects in ZnGeP2 single crystal have been visualized by using the digital holography camera. Type, geometrical sizes and positioning of founded defects were determined. Based on this information researching zones were chosen on the test ZnGeP2 plate. Measurements of absorption coefficient and refractive index in THz range were carried out. It is shown that in the frequency range 0,3-1 THz the difference of absorption coefficients reaches the value Δα = 0.2 cm-1 between “clear” zones and zones with volumetric defects. In same time, maximum difference by refractive index is about Δnmax = 0,0015.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.
The alert did not successfully save. Please try again later.
Mikhail M. Zinovev, Nikolay N. Yudin, Yelena V. Zhuravlyova, Sergey N. Podzyvalov, "Influence of ZnGeP2 volumetric defects on the spectral characteristics in THz range," Proc. SPIE 11582, Fourth International Conference on Terahertz and Microwave Radiation: Generation, Detection, and Applications, 115821M (17 November 2020); https://doi.org/10.1117/12.2582490