15 February 2021 Chest CBCT-based synthetic CT using cycle-consistent adversarial network with histogram matching
Richard L. J. Qiu, Yang Lei, Aparna H. Kesarwala, Kristin Higgins, Jeffrey D. Bradley M.D., Walter J. Curran, Tian Liu, Xiaofeng Yang
Author Affiliations +
Abstract
Image-guided radiation therapy (IGRT) is an important technological advancement that has significantly contributed to the accuracy of radiation oncology treatment plan delivery in the last decade. However, the current standard IGRT technique of linac-mounted kilovoltage (kV) cone-beam Computed Tomography (CBCT) has limited soft tissue contrast and is prone to image artifacts, which detract from its clinical utility. It is even worse in chest CBCT compared to other anatomic sites due to respiratory motion, which could lead to mistreatment. Therefore, it is highly desirable to improve CBCT image quality to the level of a planning CT scan. In this study, we propose a novel deep learning-based method, which integrates histogram matching (HM) into a cycle-consistent adversarial network (CycleGAN) framework called HM-CycleGAN, to learn a mapping between chest CBCT images and paired planning CT images obtained at simulation. Histogram matching is performed via an informative maximizing (MaxInfo) loss calculated between planning CT and the synthetic CT (sCT) derived by feeding CBCT into the HM-CycleGAN. The proposed algorithm was evaluated using 15 sets of patient chest CBCT data, each of which has 3-5 daily CBCTs. The planning/simulation CT was used as ground truth for sCTs derived from CBCTs. The mean absolute error (MAE), peak signal-to-noise ratio (PSNR), and normalized cross-correlation (NCC) indices were used to quantify the correction accuracy of the proposed algorithm. The mean MAE, PSNR and NCC were 63.2 HU, 30.2 dB, 0.96 over all CBCT fractions. The proposed method showed superior image quality, reduced noise, and artifact severity compared to the scatter correction method. Upon further improvement and clinical assessment, this method could further enhance accuracy of the current IGRT technique. The CBCT-based synthetic CT could be the critical component to achieve online adaptive radiation therapy.
© (2021) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Richard L. J. Qiu, Yang Lei, Aparna H. Kesarwala, Kristin Higgins, Jeffrey D. Bradley M.D., Walter J. Curran, Tian Liu, and Xiaofeng Yang "Chest CBCT-based synthetic CT using cycle-consistent adversarial network with histogram matching", Proc. SPIE 11596, Medical Imaging 2021: Image Processing, 115961Z (15 February 2021); https://doi.org/10.1117/12.2581094
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Chest

Image quality

Computed tomography

Radiotherapy

Signal to noise ratio

Image quality standards

Radiation oncology

Back to Top