19 May 2022 Skin oxygen saturation measurement using a non-contact optical device: optical phantoms development and metrological characterization
Author Affiliations +
Abstract
In the current study, we perform the metrological characterization of the device called IPAM which is a non-contact optical device for the measurement of skin (cutaneous) oxygen saturation rate (ScO2) in the framework of critical limb ischemia. IPAM reflectance measurement is sensitive to the differential absorption spectra of oxy- and deoxyhemoglobin. Spectrophotometry was chosen as the gold standard method to measure the oxygen saturation rate of hemoglobin solutions: results validate the fact that the IPAM device is sensitive to the modification of hemoglobin oxygen saturation rate but also that it is able of measuring the same orders of magnitude of variations as the gold standard method. The metrological characterization on seven healthy volunteers showed that the IPAM device measurement precision is 0.83. Intra-individual variability was measured as significant for four out of the seven healthy volunteers. Inter-individual variability was proven to be statistically significant and ambient light showed no impact on the ScO2 measurements performed by the IPAM device. Such results will have to be taken into account in order to correctly interpret clinical data that will be acquired during a future clinical study: only variation of measurements greater than 0.83 will be interpreted as significant, measurements may be performed in any lighting environment (natural or artificial light, low or high-lighting environments) and data can be interpreted (e.g. as “normal” or “low” oxygen saturation rate) only in comparison with a reference skin zone from the same patient.
© (2022) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Julien Azzi, Philippe Arnoux, Hanène Mansour, Louis Botrus , Sébastien Le Cunff, Athanase Benetos, Walter Blondel, and Marine Amouroux "Skin oxygen saturation measurement using a non-contact optical device: optical phantoms development and metrological characterization", Proc. SPIE 12147, Tissue Optics and Photonics II, 1214703 (19 May 2022); https://doi.org/10.1117/12.2621655
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Oxygen

Metrology

Absorbance

Skin

Optical components

Spectrophotometry

Cameras

Back to Top