Paper
1 May 1990 Extracting motion parameters from the left ventricle angiography data
Author Affiliations +
Proceedings Volume 1245, Biomedical Image Processing; (1990) https://doi.org/10.1117/12.19552
Event: Electronic Imaging: Advanced Devices and Systems, 1990, Santa Clara, CA, United States
Abstract
This paper presents a new approach for extracting surface motion parameters from the left ventricle (LV) data. The data are obtained using biplane (stereo) cineangiography and provided by Dr. David Smith [23]. The data set consists of 3-D coordinates of 30 bifurcation points on the surface of LV through several time frames. If an object undergoes rigid motion, the standard motion parameters are the translation vector and rotation matrix. The above parameters are not sufficient to describe the nonrigid motion, of which the LV motion is an example. Hence, we define the local surface stretching as an additional (with global rotation and translation) motion parameter. The process of recovering the stretching factor from the angiography data consists of three steps. At the first step, the surface of LV is reconstructed at each time instant. The reconstruction procedure involves converting data into polar coordinate system. Then the surface is reconstructed by applying the relaxation (iterative averaging) algorithm in polar coordinates. During the second step we calculate Gaussian curvature at each bifurcation point at each time instant. This achieved by least-squares surface fitting in the window around each point of interest. The third step is actual stretching factor recovery, which is based on comparison of Gaussian curvatures before and after the motion. This formula was first suggested in [11]. The final results of the algorithm are the reconstructed LV surface at each time instant together with cumulative stretching curves for each given bifurcation point.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Dmitry B. Goldgof, Hua Lee, and Thomas S. Huang "Extracting motion parameters from the left ventricle angiography data", Proc. SPIE 1245, Biomedical Image Processing, (1 May 1990); https://doi.org/10.1117/12.19552
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Angiography

Reconstruction algorithms

Image processing

Biomedical optics

Data modeling

Heart

Motion analysis

Back to Top