Paper
27 December 1977 Reciprocity Law Failure In Green Sensitive X-Ray Films
Ben A. Arnold, Bengt E. Bjarngard, Harvey Eisenberg
Author Affiliations +
Proceedings Volume 0127, Application of Optical Instrumentation in Medicine VI; (1977) https://doi.org/10.1117/12.955924
Event: Application of Optical Instrumentation in Medicine VI, 1977, Boston, United States
Abstract
Reciprocity law failure was measured for four brands of medical X-ray films exposed with intensifying screens. Three of the films are green light sensitized for use in combination with green light emitting rare-earth screens. These films showed larger reciprocity failure effects than one conventional blue sensitive film, Dupont Cronex-2. The development conditions had a small effect on reciprocity failure. The effect of reciprocity failure on the measurements of physical image quality parameters is discussed.
© (1977) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Ben A. Arnold, Bengt E. Bjarngard, and Harvey Eisenberg "Reciprocity Law Failure In Green Sensitive X-Ray Films", Proc. SPIE 0127, Application of Optical Instrumentation in Medicine VI, (27 December 1977); https://doi.org/10.1117/12.955924