1 April 2024 Thermometry mapping during CT-guided thermal ablations: sensitivity and clinical feasibility using spectral CT
Kuan Zhang, Andrea Ferrero, MyungHo In, Christopher P. Favazza
Author Affiliations +
Abstract
In this work, we aimed to investigate the sensitivity of spectral CT to changes in temperatures. Moreover, we assessed the accuracy and precision of spectral CT to provide temperature mapping within the treatment volume in CT-guided hypo- and hyper-thermal tumor ablations. Leveraging optical temperature sensors and a 3D printed phantom holder designed to precisely position metallic thermal ablation applicators and reduce the associated image artifacts, we collected spectral CT data spanning a wide range of temperatures (-100 to +90°C) and used a robust theoretical model to fit these distributions for both conventional and spectral CT data. From these expressions, look-up tables that map temperature to CT were generated within the temperature range of interest for cryoablation and hyperthermal ablations, respectively. Consistent with expectations from theoretical models for a water-based gel material, we demonstrated similar sensitivity for conventional and spectral results, with a 3-fold increase in sensitivity in the heating temperature range compared to frozen material. Next, we used repeated scans of a multi-energy phantom to determine the imaging protocol that yield the highest precision (standard deviation of average signal through repeated measurements) in CT signal at the radiation dose levels used in our practice for treatment monitoring during thermal ablation. Our data revealed the complex interplay among radiation dose, image noise, and material decomposition accuracy for spectral data. With a 5mGy CTDIvol limit, we obtained a standard deviation of the average value within a 33 mm3 VOI value of 0.85HU-equivalent for electron density images, corresponding to a precision of 7°C and 2°C for frozen and heated gel, respectively. Conventional image data, including with the application of an in-house CNN denoising algorithm, was unable to reduce the standard deviation of ROI measurements below 1HU. This information was used to develop a clinical-ready CT thermometry protocol that was subsequently independently tested on hyper-thermal measurements, demonstrating an accuracy (root mean square error) in temperature estimates of <8°C for heated gel.
Conference Presentation
(2024) Published by SPIE. Downloading of the abstract is permitted for personal use only.
Kuan Zhang, Andrea Ferrero, MyungHo In, and Christopher P. Favazza "Thermometry mapping during CT-guided thermal ablations: sensitivity and clinical feasibility using spectral CT", Proc. SPIE 12925, Medical Imaging 2024: Physics of Medical Imaging, 129251R (1 April 2024); https://doi.org/10.1117/12.3008671
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Temperature metrology

Ablation

Thermometry

Computed tomography

Reconstruction algorithms

Data modeling

Medical image reconstruction

Back to Top