Paper
1 September 1990 Precise calculation of the integrated emissivity of a multiple-celled large-area blackbody source
Wei Zhang, Zhi Xie, Kuiming Gao
Author Affiliations +
Abstract
Precise calculation of integrated emissivity of a multiple-celled large-area blackbody source has been a very complex problem. The kernel of the problem is to compute radiant exchange between the sub-cavities and a non-coaxial detector. On the basis of the method for computing radiant exchange between a cavity and a coaxial detector, a method has been developed in this paper to calculate the noncoaxial radiant exchange by which the integrated emissivity of the multiple-celled large-area blackbody source was computed accurately. The emitting area of the blackbody is of 200x200 ma that includes more than 1600 sub-cavities.
© (1990) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Wei Zhang, Zhi Xie, and Kuiming Gao "Precise calculation of the integrated emissivity of a multiple-celled large-area blackbody source", Proc. SPIE 1311, Characterization, Propagation, and Simulation of Infrared Scenes, (1 September 1990); https://doi.org/10.1117/12.21859