Paper
9 February 1993 High-temperature, highly accurate fiber optic liquid-level sensor
Anbo Wang, Michael F. Gunther, Kent A. Murphy, Richard O. Claus
Author Affiliations +
Abstract
A novel intensity-based liquid level sensor which operates up to 300 degree(s)C is described in this paper. Liquid level measurements for different liquids with refractive index ranging from 1.33 to 1.635 have been obtained with extinction ratios between 20 dB and 39 dB. Measurement hysteresis for measurement of lubricate oil was 0.175 mm.
© (1993) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Anbo Wang, Michael F. Gunther, Kent A. Murphy, and Richard O. Claus "High-temperature, highly accurate fiber optic liquid-level sensor", Proc. SPIE 1799, Specialty Fiber Optic Systems for Mobile Platforms and Plastic Optical Fibers, (9 February 1993); https://doi.org/10.1117/12.141352
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Liquids

Refractive index

Fiber optics sensors

Head

Cladding

Fiber optics

Back to Top