Paper
17 May 1996 Vaporization and coagulation potentials of the new electrosurgical rollerbar devices for transurethral prostatectomy as compared to contact laser fibers
Christiaan F. P. van Swol, Robert-Jan Hillenius, Remco J. van Vliet, Rudolf M. Verdaasdonck, Tom A. Boon
Author Affiliations +
Abstract
Laser prostatectomy is at present an established alternative for transurethral electroresection of the prostate (TUR-P). To compete with the different laser techniques, new electrosurgical modalities were developed as replacement for the standard electrosurgery tools for TUR-P. These modalities consist of a grooved cylinder fitted at the end of a TUR-P-element and are designed to combine both vaporization and coagulation in one device. The aim of this study was to investigate the potentials of the new 'rollerbar' devices and compare them with contact laser devices. Four different 'rollerbars' (Ciron, Storz and Prosurg), standard rollerball (Storz), and contact fibers (SLT) were applied to bovine myocard tissue submerged in glycine (electro) or saline (laser). The Valley Laboratory Force 40 and Force 300 were used as electrosurgical units; an MBB 4060 as Nd:YAG laser. Power settings ranged from 100 to 300 Watt (pure cut mode) for the electrosurgery device. The laser settings ranged from 10 to 60 Watt. The devices were moved over the tissue with a constant speed, while constant force was applied. The direct thermal effect of the devices was studied with a special thermal imaging technique on phantom tissue. Results show the vaporizing and coagulating power of the different devices. The rollerball (adjusted to high electrical power, i.e., 200 Watt) and the contact fibers provide similar vaporizing potential as the special-developed 'rollerbar' devices. Coagulation, necessary for hemostasis, is in all cases limited to a depth of about 2 mm. Increasing the electrical power from 200 to 300 watt only slightly increased the affected volume. The presented 'rollerbars' have a clear vaporizing and coagulating effect on tissue. The standard rollerball and contact laser fibers show similar capacities as the special-designed rollerbars.
© (1996) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Christiaan F. P. van Swol, Robert-Jan Hillenius, Remco J. van Vliet, Rudolf M. Verdaasdonck, and Tom A. Boon "Vaporization and coagulation potentials of the new electrosurgical rollerbar devices for transurethral prostatectomy as compared to contact laser fibers", Proc. SPIE 2671, Lasers in Surgery: Advanced Characterization, Therapeutics, and Systems VI, (17 May 1996); https://doi.org/10.1117/12.240035
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Tissues

Laser tissue interaction

Fiber lasers

Electrodes

Standards development

Prostate

Nd:YAG lasers