4 April 1997 Singlet oxygen generator for a supersonic chemical oxygen iodine laser: parametric study and recovery of chemicals
Author Affiliations +
Abstract
A jet singlet oxygen generator for a supersonic chemical oxygen-iodine laser was studied including singlet delta oxygen, O2(1(Delta) g), and residual chlorine concentration measurements. The investigation was intended mainly for a water vapor measurement in gas effluent of generator in dependence on properties of liquid jets: a chemical composition and temperature of the input liquid (alkaline solution of hydrogen peroxide), a liquid jets diameter and their geometrical arrangement. Effects of these parameters on output power of a small-scale supersonic laser were studied as well. Possible approaches to a chemical fuels management in a chemical oxygen-iodine laser for industrial applications are considered. An 'open loop' cycle with a possible use of sodium hydroxide, and a 'closed loop' cycle with a regeneration of both potassium hydroxide and hydrogen peroxide are discussed.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Otomar Spalek and Jarmila Kodymova "Singlet oxygen generator for a supersonic chemical oxygen iodine laser: parametric study and recovery of chemicals", Proc. SPIE 2987, Gas and Chemical Lasers and Applications II, (4 April 1997); https://doi.org/10.1117/12.271571
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Liquids

Chlorine

Oxygen

Chemical oxygen iodine lasers

Hydrogen

Chlorine gas

Chemical lasers

Back to Top