Paper
11 July 1997 Toward the calibration of the HETGS line response function
Herman L. Marshall, Daniel Dewey, Kathryn A. Flanagan, C. Baluta, Claude R. Canizares, D. S. Davis, John E. Davis, T. T. Fang, D. P. Huenemoerder, Joel H. Kastner, Norbert S. Schulz, Michael W. Wise, Jeremy J. Drake, Jiahong Zhang Juda, Michael Juda, A. C. Brinkman, C. J. Th. Gunsing, Jelle S. Kaastra, Gisela D. Hartner, Peter Predehl
Author Affiliations +
Abstract
The high-energy transmission grating for AXAF was tested with the AXAF HRMA during December 1996 through April 1997 at NASA's MSFC X-Ray Calibration Facility. This first-use of the complete HETG spectrometer (HETGS) produced some low-level surprises in the line response function (LRF) and indicate that the HETG is meeting or exceeding its resolving-power specifications. This paper reviews the ingredients of the HETGS LRF, describes the pre-XRCF HETG sub-assembly measurements, presents an overview of the XRCF LRF-related measurements and data, and summarizes our knowledge of the HETG contribution to the HETGS line response function. Two low-level effects, grating scatter and grating misalignment, were uncovered in this testing.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Herman L. Marshall, Daniel Dewey, Kathryn A. Flanagan, C. Baluta, Claude R. Canizares, D. S. Davis, John E. Davis, T. T. Fang, D. P. Huenemoerder, Joel H. Kastner, Norbert S. Schulz, Michael W. Wise, Jeremy J. Drake, Jiahong Zhang Juda, Michael Juda, A. C. Brinkman, C. J. Th. Gunsing, Jelle S. Kaastra, Gisela D. Hartner, and Peter Predehl "Toward the calibration of the HETGS line response function", Proc. SPIE 3113, Grazing Incidence and Multilayer X-Ray Optical Systems, (11 July 1997); https://doi.org/10.1117/12.278844
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Laser range finders

Sensors

Calibration

Point spread functions

Magnetoencephalography

Scattering

Spectral resolution

RELATED CONTENT

NuSTAR on-ground calibration: I. Imaging quality
Proceedings of SPIE (September 17 2012)
X-ray tests and calibrations of the ABRIXAS mirror systems
Proceedings of SPIE (November 19 1998)
Calibrating the wings of the Chandra PSF
Proceedings of SPIE (February 03 2004)
Uses of continuum radiation in the AXAF calibration
Proceedings of SPIE (July 11 1997)
Verifying the HETG spectrometer Rowland design
Proceedings of SPIE (November 19 1998)
X ray measurements of a prototype WFXT SiC mirror at...
Proceedings of SPIE (September 29 1999)

Back to Top