Paper
15 October 1997 Institut d'Astrophysique Spatiale (IAS) 0.1- to 15-keV Synchrotron Radiation Facility beam lines
Pierre Dhez, Erick Jourdain, Olivier Hainaut, Jean-Francois E. Hochedez, Alain Labeque, Philippe Salvetat, Xueyan Song
Author Affiliations +
Abstract
Two beam lines have been built at the Institute d'Astrophysique Spatiale (IAS) d'Orsay to perform absolute calibration of the EPIC (European photon imaging camera). EPIC consists of three x-ray charge coupled device (CCD) cameras having imaging and spectroscopic performances set at the Wolter telescope focal planes on board the x-ray multi mirror mission (XMM) planned to be launched by ESA in August 1999. To cover the desired 0.1 - 15 keV range a dedicated beam line has been built on each synchrotron sources of the Laboratoire pour l'Utilisation du Rayonnement Synchrotron (LURE): SACO (0.8 GeV) and DCI (1.5 GeV). Both beam lines are merging in a clean 23 m3 vacuum tank containing the camera to calibrate. (1) The SACO windowless beam line is equipped with a grating monochromator. Four plane VLS gratings are used to cover the low energy range (0.1 - 1.2 keV). A triple grazing incidence mirror system set in front of the entrance slit removes the overlapping orders. (2) The high energy beam line on DCI has a 50 micrometer beryllium window and a double flat crystals monochromator equipped with four different crystal pairs. A double grazing incidence mirror system set close to the source absorbs the high energy photon spectra. CCD calibrations will be performed during 1997 second semester and years 1998.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Pierre Dhez, Erick Jourdain, Olivier Hainaut, Jean-Francois E. Hochedez, Alain Labeque, Philippe Salvetat, and Xueyan Song "Institut d'Astrophysique Spatiale (IAS) 0.1- to 15-keV Synchrotron Radiation Facility beam lines", Proc. SPIE 3114, EUV, X-Ray, and Gamma-Ray Instrumentation for Astronomy VIII, (15 October 1997); https://doi.org/10.1117/12.278911
Lens.org Logo
CITATIONS
Cited by 8 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Monochromators

Cameras

Crystals

Calibration

Mirrors

Synchrotrons

Jupiter

RELATED CONTENT

Gaussian like shaping of coherent synchrotron x rays 3D...
Proceedings of SPIE (August 11 2008)
Incoherent x-ray mirror surface metrology
Proceedings of SPIE (November 01 1997)
Ground calibration of the XMM EPIC MOS cameras at the...
Proceedings of SPIE (October 22 1999)
PN CCD camera for XMM performance of high time...
Proceedings of SPIE (October 15 1997)

Back to Top