1 November 1997 Spatial coherence of a capillary discharge soft x-ray amplifier
Juan L. A. Chilla, Mario C. Marconi, Jorge J. G. Rocca, Cesar H. Moreno, Brady R. Benware
Author Affiliations +
Abstract
We have measured the variation of the spatial coherence with plasma column length in a saturated table-top 46.9 nm Ne-like Ar capillary discharge soft x-ray amplifier for lengths up to 16.4 cm. The measurements, which are in good agreement with time dependent wave-optics model computations, provide the first experimental evidence of a monotonic increase of the coherence with length in a soft x-ray amplifier. The variation of the coherence across the beam profile was also studied. Off-axis the coherence is larger in the tangential than in the radical direction.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Juan L. A. Chilla, Mario C. Marconi, Jorge J. G. Rocca, Cesar H. Moreno, and Brady R. Benware "Spatial coherence of a capillary discharge soft x-ray amplifier", Proc. SPIE 3156, Soft X-Ray Lasers and Applications II, (1 November 1997); https://doi.org/10.1117/12.284826