Paper
13 October 1999 Phase-continuous scan DSPI technique for measuring vibration mode
Author Affiliations +
Abstract
The phase continuous scan technique is combined with the Bessel fringe-shifting technique to quantitatively analyze the vibration mode by time-averaging DSPI. Through the phase continuous scan, the background and speckle items are completely eliminated, which improves the fringe quality and enhances the signal-to-noise ratio of interferogram. There is no need to calibrate the optical phase-shifter exactly in this method. The anti-disturbance capability of this method is higher than that of the phase-stepping technique, so it is robust and easy to be used.
© (1999) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Shuhai Jia, Kaiduan Yue, and Yushan Tan "Phase-continuous scan DSPI technique for measuring vibration mode", Proc. SPIE 3783, Optical Diagnostics for Fluids/Heat/Combustion and Photomechanics for Solids, (13 October 1999); https://doi.org/10.1117/12.365763