Paper
3 May 2000 Comparison of 2D temperature maps recorded during laser-induced thermal tissue treatment with corresponding temperature distributions calculated from 3D Monte-Carlo simulations
Harald Busse, Martin Bublat, Ralf Ratering, Margarethe Rassek, Hans-Joachim Schwarzmaier M.D., Thomas Kahn M.D.
Author Affiliations +
Abstract
Minimally invasive techniques often require special biomedical monitoring schemes. In the case of laser coagulation of tumors accurate temperature mapping is desirable for therapy control. While magnetic resonance (MR)-based thermometry can easily yield qualitative results it is still difficult to calibrate this technique with independent temperature probes for the entire 2D field of view. Calculated temperature maps derived from Monte-Carlo simulations (MCS), on the other hand, are suitable for therapy planning and dosimetry but typically can not account for the extract individual tissue parameters and physiological changes upon heating. In this work, online thermometry was combined with MCS techniques to explore the feasibility and potential of such a biomodal approach for surgical assist systems. For the first time, the result of a 3D simulation were evaluated with MR techniques. An MR thermometry system was used to monitor the temperature evolution during laser-induced thermal treatment of bovine liver using a commercially available water-cooled applicator. A systematic comparison between MR-derived 2D temperature maps in different orientations and corresponding snapshots of a 3D MCS of the laser-induced processes is presented. The MCS is capable of resolving the complex temperature patterns observed in the MR-derived images and yields a good agreement with respect to absolute temperatures and damage volume dimensions. The observed quantitative agreement is around 10 degrees C and on the order of 10 percent, respectively. The integrated simulation-and-monitoring approach has the potential to improve surgical assistance during thermal interventions.
© (2000) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Harald Busse, Martin Bublat, Ralf Ratering, Margarethe Rassek, Hans-Joachim Schwarzmaier M.D., and Thomas Kahn M.D. "Comparison of 2D temperature maps recorded during laser-induced thermal tissue treatment with corresponding temperature distributions calculated from 3D Monte-Carlo simulations", Proc. SPIE 3911, Biomedical Diagnostic, Guidance, and Surgical-Assist Systems II, (3 May 2000); https://doi.org/10.1117/12.384900
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Monte Carlo methods

Tissues

Tissue optics

Computer simulations

Thermometry

Laser tissue interaction

Magnetic resonance imaging

Back to Top