11 March 2003 Status of the EPIC/MOS calibration onboard XMM-Newton
Philippe Ferrando, Anthony F. Abbey, Bruno Altieri, Monique Arnaud, Paul J. Bennie, Mauro Dadina, Mark Denby, Simona Ghizzardi, R. Gareth Griffiths, Marcus Kirsch, Nicola La Palombara, A. de Luca, David H. Lumb, Silvano Molendi, Doris Neumann, Jean Luc Sauvageot, Richard Saxton, Steve Sembay, Andrea Tiengo, Martin J. L. Turner
Author Affiliations +
Abstract
The XMM-Newton observatory has the largest collecting area flown so far for an X-ray imaging system, resulting in a very high sensitivity over a broad spectral range. In order to exploit fully these performances, an accurate calibration of the XMM-Newton instruments is required. This calibration is being continuously updated, in order to refine the stable calibration parameters as well as to account for the detector response changes induced by radiation damage. We report here on the current overall status of the EPIC/MOS cameras calibrations, and in particular on the recent work involving Charge Transfer Inefficiency evolution and recovery.
© (2003) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Philippe Ferrando, Anthony F. Abbey, Bruno Altieri, Monique Arnaud, Paul J. Bennie, Mauro Dadina, Mark Denby, Simona Ghizzardi, R. Gareth Griffiths, Marcus Kirsch, Nicola La Palombara, A. de Luca, David H. Lumb, Silvano Molendi, Doris Neumann, Jean Luc Sauvageot, Richard Saxton, Steve Sembay, Andrea Tiengo, and Martin J. L. Turner "Status of the EPIC/MOS calibration onboard XMM-Newton", Proc. SPIE 4851, X-Ray and Gamma-Ray Telescopes and Instruments for Astronomy, (11 March 2003); https://doi.org/10.1117/12.461310
Lens.org Logo
CITATIONS
Cited by 3 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calibration

Cameras

Charge-coupled devices

Molybdenum

CCD cameras

Mirrors

Optical filters

RELATED CONTENT

XMM science simulator: EPIC mode performance issues
Proceedings of SPIE (November 10 1998)
Ground calibration GSE for the XMM EPIC instrument at the...
Proceedings of SPIE (November 10 1998)
eROSITA in orbit calibration strategy and plan from the...
Proceedings of SPIE (September 13 2012)
PN CCD camera for XMM performance of high time...
Proceedings of SPIE (October 15 1997)
EPIC system onboard the ESA XMM
Proceedings of SPIE (October 31 1996)

Back to Top