Paper
14 January 1986 Large Photocathode Streak Tube
Katsuyuki Kinoshita, Masuo Ito, Yoshinori Inagaki, Tsutomu Nakamura, Teruo Takeshita, Koichiro Oba
Author Affiliations +
Abstract
A. large photocathode streak tube has been developed. The useful photocathode length is 25 mm and the useful output screen size is 32.5 mm(spatial direction) x 40 mm(temporal direction). The tube has time resolution of about 8 ps and good deflection sensitivity of 60 mm/KV. As for dynamic spatial resolution, amplitude response better than 12% at 20 1p/mm referred to the photocathode has been obtained to input square-wave test pattern over the area of 80% of useful output screen at light wavelength of 800 nm. Also the geometric distortion less than 1% and the shading of output signal less than 15% have been obtained.
© (1986) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Katsuyuki Kinoshita, Masuo Ito, Yoshinori Inagaki, Tsutomu Nakamura, Teruo Takeshita, and Koichiro Oba "Large Photocathode Streak Tube", Proc. SPIE 0569, High Speed Photography, Videography, and Photonics III, (14 January 1986); https://doi.org/10.1117/12.949879
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Spatial resolution

Distortion

Electrodes

Temporal resolution

High speed photography

Photonics

Picosecond phenomena

RELATED CONTENT

Femtosecond Streak Image Tube
Proceedings of SPIE (March 01 1983)
Characterization Of Photon-Counting Streak Camera
Proceedings of SPIE (December 08 1986)
A Picosecond Streak Image Tube
Proceedings of SPIE (February 01 1985)
Femtosecond streak image converter camera
Proceedings of SPIE (January 01 1993)

Back to Top