Paper
18 August 2005 Detector response of GSC/MAXI and its expected performance in orbit
Yuichiro Tsuchiya, Atsumasa Yoshida, Kazutaka Yamaoka, Tomomichi Arakuni, T. Miyakawa, Masaru Matsuoka, Shiro Ueno, Hiroshi Tomida, Takao Yokota, Kazuyoshi Kawasaki, Naoyuki Kuramata, Haruyoshi Katayama, Mikio Morii, Tatehiro Mihara, Motoki Nakajima, Naoki Isobe, Mitsuhiro Kohama, Hiroshi Tsunemi, Emi Miyata, Nobuyuki Kawai, Jun Kataoka, Hitoshi Negoro
Author Affiliations +
Abstract
Monitor of All-sky X-ray Image(MAXI) is an X-ray all sky monitor, which will be attached to the Japanese Experiment Module (JEM) on the International Space Station (ISS) around the year 2008. MAXI carries two types of scientific instruments. The Gas Slit Camera(GSC) consists of twelve Xe filled one-dimensional position sensitive gas proportional counters sensitive to X-ray in 2-30 keV band. The Solid-state Slit Camera (SSC) is a set of X-ray CCD arrays sensitive to 0.5-10 keV photons. Both detectors are utilized in combination with a slit and orthogonally arranged collimator plates to produce one-dimensional X-ray images along sky great circles. The instruments are now under fabrication and preflight testing. A detector response matrix (DRM) of GSC is also under development phase based on flight model calibration tests for counters and collimators. MAXI's overall performance depends on not only hardware characteristics but on the fact that the field-of-view changes in time even during observations. To study this complicated situation, we are developing a software, DRM builder, and also a simulation software to evaluate "realistic" performance of GSC in ISS orbits.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Yuichiro Tsuchiya, Atsumasa Yoshida, Kazutaka Yamaoka, Tomomichi Arakuni, T. Miyakawa, Masaru Matsuoka, Shiro Ueno, Hiroshi Tomida, Takao Yokota, Kazuyoshi Kawasaki, Naoyuki Kuramata, Haruyoshi Katayama, Mikio Morii, Tatehiro Mihara, Motoki Nakajima, Naoki Isobe, Mitsuhiro Kohama, Hiroshi Tsunemi, Emi Miyata, Nobuyuki Kawai, Jun Kataoka, and Hitoshi Negoro "Detector response of GSC/MAXI and its expected performance in orbit", Proc. SPIE 5898, UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XIV, 58981F (18 August 2005); https://doi.org/10.1117/12.616434
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Photons

Collimators

Sensors

Phase modulation

Cameras

X-ray detectors

RELATED CONTENT

VTXO: the virtual telescope for x-ray observations
Proceedings of SPIE (December 13 2020)
CT detector evaluation with complex random backgrounds
Proceedings of SPIE (March 12 2012)
Large format CID x-ray image sensors
Proceedings of SPIE (April 01 1998)
Measurements of micro focus spot size (0.005 0.1mm) in x...
Proceedings of SPIE (December 07 2006)

Back to Top