Paper
28 October 2005 High-performance field-portable imaging radiometric spectrometer technology for chemical agent detection
Alexandre Vallières, Martin Chamberland, Vincent Farley, Louis Belhumeur, André Villemaire, Jean Giroux, Jean-François Legault
Author Affiliations +
Proceedings Volume 5990, Optically Based Materials and Optically Based Biological and Chemical Sensing for Defence II; 59900U (2005) https://doi.org/10.1117/12.632069
Event: European Symposium on Optics and Photonics for Defence and Security, 2005, Bruges, Belgium
Abstract
Standoff detection, identification and quantification of chemicals in the gaseous state are fundamental needs in several fields of applications. Additional required sensor characteristics include high sensitivity, low false alarms and high-speed (ideally real-time) operation, all in a compact and robust package. The thermal infrared portion of the electromagnetic spectrum has been utilized to implement such chemical sensors, either with spectrometers (with none or moderate imaging capability) or with imagers (with moderate spectral capability). Only with the recent emergence of high-speed, large format infrared imaging arrays, has it been possible to design chemical sensors offering uncompromising performance in the spectral, spatial, as well as the temporal domain. Telops has developed a novel instrument that can not only provide an early warning for chemical agents and toxic chemicals, but also one that provides a "Chemical Map" of the field of view and is man portable. To provide to best field imaging spectroscopy instrument, Telops has developed the FIRST, Field-portable Imaging Radiometric Spectrometer Technology, instrument. This instrument is based on a modular design that includes: a high performance infrared FPA and data acquisition electronics, onboard data processing electronics, a high performance Fourier transform modulator, dual integrated radiometric calibration targets and a visible boresighted camera. These modules, assembled together in an environmentally robust structure, used in combination with Telops' proven radiometric and spectral calibration algorithms make this instrument a world-class passive standoff detection system for chemical imaging.
© (2005) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Alexandre Vallières, Martin Chamberland, Vincent Farley, Louis Belhumeur, André Villemaire, Jean Giroux, and Jean-François Legault "High-performance field-portable imaging radiometric spectrometer technology for chemical agent detection", Proc. SPIE 5990, Optically Based Materials and Optically Based Biological and Chemical Sensing for Defence II, 59900U (28 October 2005); https://doi.org/10.1117/12.632069
Lens.org Logo
CITATIONS
Cited by 12 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Detection and tracking algorithms

Image filtering

Electronic filtering

Sensors

Spectroscopy

Infrared imaging

Standoff detection

RELATED CONTENT


Back to Top