Paper
2 March 2006 Comparison of polychromatic and monochromatic x-rays for imaging
M. Hoheisel, P. Bernhardt, R. Lawaczeck, H. Pietsch
Author Affiliations +
Abstract
Monochromatic X-rays have been proposed for medical imaging, especially in the mammographic energy range. Our previous investigations have shown that the contrast of objects such as lesions or contrast media can be enhanced considerably by using monochromatic X-rays instead of the common polychromatic spectra. Admittedly, only one specific polychromatic spectrum and one monochromatic energy have been compared so far. In this work, we investigated the contrast yielded by a series of different X-ray spectra obtained by varying tube voltage and beam filtering. This resulted in spectra of different mean energies and spectral widths. The objects under examination were aqueous solutions containing different chemical elements such as I, Gd, Dy, Yb, and Bi. A monoenergetic spectrum at 17.5 keV was obtained using a mammographic X-ray tube with a Mo anode and a monochromator equipped with a HOPG crystal. Moreover, we simulated quasi-monoenergetic spectra at different energies and with different widths. As a result, we demonstrated that in many cases spectra with an energetic width of some keV yield an equivalent contrast to monoenergetic radiation at the same energy. Therefore, the advantage in image contrast of monochromatic X-rays at 17.5 keV over narrow-band polychromatic X-ray spectra obtained by appropriate filtering is only slight. Thus, the additional expenditure on a mammography system with HOPG monochromator that can deliver only a small X-ray dose and the unfavorable slot-scan geometry can be avoided. Moreover, we carried out simulations of monochromatic versus polychromatic spectra throughout the whole radiographic energy range. We found advantages in using monochromatic X-rays at higher energies and thicker objects that will justify their application for diagnostic imaging in a number of specific cases.
© (2006) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
M. Hoheisel, P. Bernhardt, R. Lawaczeck, and H. Pietsch "Comparison of polychromatic and monochromatic x-rays for imaging", Proc. SPIE 6142, Medical Imaging 2006: Physics of Medical Imaging, 614209 (2 March 2006); https://doi.org/10.1117/12.651037
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Bismuth

X-ray imaging

Aluminum

Molybdenum

Optical filters

Dysprosium

RELATED CONTENT

Imaging with multi-prism x-ray lenses
Proceedings of SPIE (March 18 2008)
Triple-energy contrast enhanced digital mammography
Proceedings of SPIE (March 18 2010)
X-Ray Beam Filtration For Mammography
Proceedings of SPIE (December 27 1977)
Analysis of the spectrum in phase-contrast mammography
Proceedings of SPIE (March 13 2009)
Modern x ray sources based on university scale 1 MA...
Proceedings of SPIE (September 18 2007)

Back to Top