Paper
1 November 2007 Experimental study of response time of magnetorheological fluid damper
X. C. Guan, P. F. Guo, C. F. Bian, J. P. Ou
Author Affiliations +
Proceedings Volume 6423, International Conference on Smart Materials and Nanotechnology in Engineering; 642333 (2007) https://doi.org/10.1117/12.779889
Event: International Conference on Smart Materials and Nanotechnology in Engineering, 2007, Harbin, China
Abstract
In this paper, the response time of one magnetorheological fluid (MR) damper with maximum damping force of 250kN was tested. Experimental results show that, when electric current increase, response time is about 0.1 to 0.3s; when current decrease and not to zero, response time is about 0.2 to 0.3s, higher change of current induce longer of response time. Experimental results also show that, when electric current decrease to zero, response time is about 0.6 to 0.7s, which is much longer than expected. Further experiment results show that, if subtracting response of coil, when current increase, the response time is about 60 to 70ms, when current decrease and not to zero, the response time is about 140 to 150ms.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
X. C. Guan, P. F. Guo, C. F. Bian, and J. P. Ou "Experimental study of response time of magnetorheological fluid damper", Proc. SPIE 6423, International Conference on Smart Materials and Nanotechnology in Engineering, 642333 (1 November 2007); https://doi.org/10.1117/12.779889
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Control systems

Computing systems

Magnetorheological finishing

Smart materials

Civil engineering

Mechanics

Performance modeling

Back to Top