Paper
20 March 2007 Effect of CAD on radiologists' detection of lung nodules on thoracic CT scans: observer performance study
Berkman Sahiner, Lubomir M. Hadjiiski, Heang -Ping Chan, Jiazheng Shi, Philip N. Cascade, Ella A. Kazerooni, Chuan Zhou, Jun Wei, Aamer R. Chughtai, Chad Poopat, Thomas Song, Jadranka S Nojkova, Luba Frank, Anil Attili
Author Affiliations +
Abstract
The purpose of this study was to evaluate the effect of computer-aided diagnosis (CAD) on radiologists' performance for the detection of lung nodules on thoracic CT scans. Our computer system was designed using an independent training set of 94 CT scans in our laboratory. The data set for the observer performance study consisted of 48 CT scans. Twenty scans were collected from patient files at the University of Michigan, and 28 scans by the Lung Imaging Database Consortium (LIDC). All scans were read by multiple experienced thoracic radiologists to determine the true nodule locations, defined as any region identified by one or more expert radiologists as containing a nodule larger than 3 mm in diameter. Eighteen CT examinations were nodule-free, while the remaining 30 CT examinations contained a total of 73 nodules having a median size of 5.5 mm (range 3.0-36.4 mm). Four other study radiologists read the CT scans first without and then with CAD, and provided likelihood of nodule ratings for suspicious regions. Two of the study radiologists were fellowship trained in cardiothoracic radiology, and two were cardiothoracic radiology fellows. Freeresponse receiver-operating characteristic (FROC) curves were used to compare the two reading conditions. The computer system had a sensitivity of 79% (58/73) with an average of 4.9 marks per normal scan (88/18). Jackknife alternative FROC (JAFROC) analysis indicated that the improvement with CAD was statistically significant (p=0.03).
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Berkman Sahiner, Lubomir M. Hadjiiski, Heang -Ping Chan, Jiazheng Shi, Philip N. Cascade, Ella A. Kazerooni, Chuan Zhou, Jun Wei, Aamer R. Chughtai, Chad Poopat, Thomas Song, Jadranka S Nojkova, Luba Frank, and Anil Attili "Effect of CAD on radiologists' detection of lung nodules on thoracic CT scans: observer performance study", Proc. SPIE 6515, Medical Imaging 2007: Image Perception, Observer Performance, and Technology Assessment, 65151D (20 March 2007); https://doi.org/10.1117/12.709851
Lens.org Logo
CITATIONS
Cited by 21 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Computer aided diagnosis and therapy

Computing systems

Computed tomography

Lung

Computer aided design

Radiology

Gold

Back to Top