20 September 2007 Comparison of slope and height profiles for flat synchrotron x-ray mirrors measured with a long trace profiler and a PMI Fizeau interferometer
Author Affiliations +
Abstract
Long trace profilers (LTPs)(1) have been used at many synchrotron radiation laboratories worldwide for over a decade to measure surface slope profiles of long grazing incidence x-ray mirrors. Phase measuring interferometers (PMIs) of the Fizeau type, on the other hand, are being used by most mirror manufacturers to accomplish the same task. However, large mirrors whose dimensions exceed the aperture of the Fizeau interferometer require measurements to be carried out at grazing incidence, and aspheric optics require the use of a null lens. While an LTP provides a direct measurement of 1D slope profiles, PMIs measure area height profiles from which the slope can be obtained by a differentiation algorithm. Measurements of the two types of instruments have been found by us to be in good agreement, but to our knowledge there is no published work directly comparing the two instruments. This paper documents that comparison. We measured two different nominally flat mirrors with both the LTP in operation at the Advanced Photon Source (a type-II LTP) and a Fizeau-type PMI interferometer (Wyko model 6000). One mirror was 500 mm long and made of Zerodur, and the other mirror was 350 mm long and made of silicon. Slope error results with these instruments agree within nearly 100% (3.11±0.15 μrad for the LTP, and 3.11±0.02μrad for the Fizeau PMI interferometer) for the medium quality Zerodur mirror with 3 μrad rms nominal slope error. A significant difference was observed with the much higher quality silicon mirror. For the Si mirror, slope error data is 0.39±0.08Χrad from LTP measurements but it is 0.35 ± 0.01 μrad from PMI interferometer measurements. The standard deviations show that the Fizeau PMI interferometer has much better measurement repeatability.
© (2007) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Jun Qian, Lahsen Assoufid, and Albert Macrander "Comparison of slope and height profiles for flat synchrotron x-ray mirrors measured with a long trace profiler and a PMI Fizeau interferometer", Proc. SPIE 6704, Advances in Metrology for X-Ray and EUV Optics II, 67040C (20 September 2007); https://doi.org/10.1117/12.734816
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mirrors

Interferometers

Silicon

Fizeau interferometers

Zerodur

Error analysis

X-rays

Back to Top