Paper
12 July 2008 Mid-infrared coronagraph for SPICA
K. Enya, L. Abe, K. Haze, S. Tanaka, T. Nakagawa, H. Kataza, S. Higuchi, T. Miyata, S. Sako, T. Nakamura, M. Tamura, J. Nishikawa, N. Murakami, Y. Itoh, T. Wakayama, T. Sato, N. Nakagiri, O. Guyon, M. Venet, P. Bierden
Author Affiliations +
Abstract
The SPace Infrared telescope for Cosmology and Astrophysics (SPICA) is a infrared space-borne telescope mission of the next generation following AKARI. SPICA will carry a telescope with a 3.5 m diameter monolithic primary mirror and the whole telescope will be cooled to 5 K. SPICA is planned to be launched in 2017, into the sun-earth L2 libration halo orbit by an H II-A rocket and execute infrared observations at wavelengths mainly between 5 and 200 micron. The large telescope aperture, the simple pupil shape, the capability of infrared observations from space, and the early launch gives us with the SPICA mission a unique opportunity for coronagraphic observation. We have started development of a coronagraphic instrument for SPICA. The primary target of the SPICA coronagraph is direct observation of extra-solar Jovian planets. The main wavelengths of observation, the required contrast and the inner working angle (IWA) of the SPICA coronagraph are set to be 5-27 micron (3.5-5 micron is optional), 10-6, and a few λ/D (and as small as possible), respectively, in which λ is the observation wavelength and D is the diameter of the telescope aperture (3.5m). For our laboratory demonstration, we focused first on a coronagraph with a binary shaped pupil mask as the primary candidate for SPICA because of its feasibility. In an experiment with a binary shaped pupil coronagraph with a He-Ne laser (λ=632.8nm), the achieved raw contrast was 6.7×10-8, derived from the average measured in the dark region without active wavefront control. On the other hand, a study of Phase Induced Amplitude Apodization (PIAA) was initiated in an attempt to achieve better performance, i.e., smaller IWA and higher throughput. A laboratory experiment was performed using a He-Ne laser with active wavefront control, and a raw contrast of 6.5×10-7 was achieved. We also present recent progress made in the cryogenic active optics for SPICA. Prototypes of cryogenic deformable by Micro Electro Mechanical Systems (MEMS) techniques were developed and a first demonstration of the deformation of their surfaces was performed with liquid nitrogen cooling. Experiments with piezo-actuators for a cryogenic tip-tilt mirror are also ongoing.
© (2008) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
K. Enya, L. Abe, K. Haze, S. Tanaka, T. Nakagawa, H. Kataza, S. Higuchi, T. Miyata, S. Sako, T. Nakamura, M. Tamura, J. Nishikawa, N. Murakami, Y. Itoh, T. Wakayama, T. Sato, N. Nakagiri, O. Guyon, M. Venet, and P. Bierden "Mid-infrared coronagraph for SPICA", Proc. SPIE 7010, Space Telescopes and Instrumentation 2008: Optical, Infrared, and Millimeter, 70102Z (12 July 2008); https://doi.org/10.1117/12.788509
Lens.org Logo
CITATIONS
Cited by 5 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Coronagraphy

Space telescopes

Cryogenics

Infrared telescopes

Telescopes

Mirrors

Binary data

RELATED CONTENT

Coronagraph project with the SPICA mission
Proceedings of SPIE (September 19 2007)
Shuttle Infrared Telescope Facility
Proceedings of SPIE (November 15 1976)
Development of an MIR coronagraph for the SPICA mission
Proceedings of SPIE (July 07 2006)
The SOLARC off-axis coronagraph
Proceedings of SPIE (February 11 2003)

Back to Top