In this paper, a theoretical analysis of the optimal package diameter of fiber Bragg grating (FBG) pressure sensors is
presented. We use the theory of elastic to analyze the relation between the pressure sensitivity and the package diameter
of FBG with d ifferent materials, structures. Then we can get the optimal package diameter of FBG pressure sensor for a
certain package structure and material. Through the following experiments, it can be proved that the theoretical analysis
is correct. This analysis could not only significantly enhance the pressure sensitivity, but also provide the optimal
package diameter of FBG for the practical applications.
Lihui Liu,Yongtai He,Fang Li, andYuliang Liu
"Analysis of the optimal package diameter of FBG pressure sensor", Proc. SPIE 7133, Fifth International Symposium on Instrumentation Science and Technology, 71331D (12 January 2009); https://doi.org/10.1117/12.821227