22 April 2009 Radiometric modeling of mechanical draft cooling towers to assist in the extraction of their absolute temperature from remote thermal imagery
Author Affiliations +
Abstract
Determining the internal temperature of a mechanical draft cooling tower (MDCT) from remotely-sensed thermal imagery is important for many applications that provide input to energy-related process models. The problem of determining the temperature of a MDCT is unique due to the geometry of the tower and due to the exhausted water vapor plume. The radiance leaving the tower is dependent on the optical and thermal properties of the tower materials (i.e., emissivity, BRDF, temperature, etc.) and also the internal geometry of the tower. The tower radiance is then propagated through the exhaust plume and through the atmosphere to arrive at the sensor. The expelled effluent from the tower consists of a warm plume with a higher water vapor concentration than the ambient atmosphere. Given that a thermal image has been atmospherically compensated, the remaining sources of error in extracted tower temperature due to the exhausted plume and the tower geometry must be accounted for. A temperature correction factor due to these error sources will be derived through the use of three-dimensional radiometric modeling. A range of values for each important parameter are modeled to create a target space (i.e., look-up table) that predicts the internal MDCT temperature for every combination of parameter values. This LUT, along with user knowledge of the scene, provides a means to convert the imagederived apparent temperature into the estimated absolute temperature of a MDCT. Preliminary results indicate that temperature error corrections of approximately 1 - 9 Kelvin can be achieved with the range of MDCT parameters encompassed by the LUT.
© (2009) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Matthew Montanaro, Carl Salvaggio, Scott D. Brown, David W. Messinger, Alfred J. Garrett, and James S. Bollinger "Radiometric modeling of mechanical draft cooling towers to assist in the extraction of their absolute temperature from remote thermal imagery", Proc. SPIE 7299, Thermosense XXXI, 729909 (22 April 2009); https://doi.org/10.1117/12.817527
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Sensors

Bidirectional reflectance transmission function

Fluctuations and noise

Thermal modeling

Thermography

Image sensors

Image processing

RELATED CONTENT

Efficient polarimetric BRDF transformations
Proceedings of SPIE (May 03 2016)
Enhanced backgrounds in scene rendering with GTSIMS
Proceedings of SPIE (May 14 2018)
Infrared animal modeling for training ATR algorithms
Proceedings of SPIE (October 26 2010)
Open source layered sensing model
Proceedings of SPIE (May 23 2011)
Concurrent engineering to the rescue Do we have the...
Proceedings of SPIE (September 03 2008)

Back to Top