20 September 2010 Tomographic imaging of coherent x-ray scatter momentum transfer distribution using spectral x-ray detection and polycapillary optic
Author Affiliations +
Abstract
Quantitation of coherent x-ray scatter traditionally involves measuring the intensity of the scattered x-ray over a range of angles (θ) from the illuminating monochromatic x-ray beam. Spectral x-ray imaging produces the same information at a single θ when bremsstrahlung x-ray exposure is used. We used a 200μm thick sheet-illumination of a phantom (lucite cylinder containing holes with water, polyethylene, collagen, polycarbonate, and nylon) and a polycapillary x-ray optic collimator to provide measurements at a fixed θ. A Medipix2 x-ray detection array (2562 (55μm)2 pixels) provided the spectral (E, 10 - 22 keV in 3keV energy bins) spread needed to generate the momentum transfer (q) profile information at one angle. The tungsten x-ray source anode (aluminum filter) was operated at 35kVp at 20mA. The detected scatter intensity was corrected for attenuation of the incident and the scattered x-ray by use of the regular CT image of the phantom generated at the same energy bins. The phantom was translated normal to the plane of the fan beam in 65, 0.2mm, steps to generate the 3D image data. The momentum transfer profiles generated with this approach were compared to published momentum transfer profiles obtained by other methods.
© (2010) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Diane R. Eaker, Steven M. Jorgensen, Anthony P. H. Butler, and Erik L. Ritman "Tomographic imaging of coherent x-ray scatter momentum transfer distribution using spectral x-ray detection and polycapillary optic", Proc. SPIE 7804, Developments in X-Ray Tomography VII, 78041O (20 September 2010); https://doi.org/10.1117/12.861508
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
X-rays

Signal attenuation

X-ray imaging

Sensors

Coherence imaging

Fluctuations and noise

X-ray detectors

RELATED CONTENT

Soil matrix study using a hybrid a Se CMOS pixel...
Proceedings of SPIE (October 17 2022)
New contrasts for x ray imaging and synergy with optical...
Proceedings of SPIE (February 15 2017)
Lab-based x-ray nanoCT imaging
Proceedings of SPIE (March 09 2017)
Design and construction of a micro focus in line phase...
Proceedings of SPIE (March 23 2010)

Back to Top