18 May 2012 In-line particle measurement in a recovery boiler using high-speed infrared imaging
Author Affiliations +
Abstract
Black liquor is the fuel of Kraft recovery boilers. It is sprayed into the furnace of a recovery boiler through splashplate nozzles. The operation of a recovery boiler is largely influenced by the particle size and particle size distribution of black liquor. When entrained by upwards-flowing flue gas flow, small droplet particles may form carry-over and cause the fouling of heat transfer surfaces. Large droplet particles hit the char bed and the walls of the furnace without being dried. In this study, particles of black liquor sprays were imaged using a high-speed infrared camera. Measurements were done in a functional recovery boiler in a pulp mill. Objective was to find a suitable wavelength range and settings such as integration time, frame rate and averaging for the camera.
© (2012) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Sami Siikanen, Pasi Miikkulainen, Marko Kaarre, and Mikko Juuti "In-line particle measurement in a recovery boiler using high-speed infrared imaging", Proc. SPIE 8354, Thermosense: Thermal Infrared Applications XXXIV, 83540M (18 May 2012); https://doi.org/10.1117/12.916146