6 March 2013 The effect of cross-scatter correction on the performance of dual energy micro-CT
D. Clark, S. M. Johnston, G. A. Johnson, C. T. Badea
Author Affiliations +
Proceedings Volume 8668, Medical Imaging 2013: Physics of Medical Imaging; 86684T (2013) https://doi.org/10.1117/12.2006904
Event: SPIE Medical Imaging, 2013, Lake Buena Vista (Orlando Area), Florida, United States
Abstract
Dual energy (DE) CT imaging is expected to play a major role in the diagnostic arena as it provides a quantitative decomposition of basis materials, opening the door for new clinical applications without significantly increasing dose to the patient. DE-CT provides a particularly unique opportunity in preclinical CT where new elemental contrast agents are providing novel approaches for quantitative tissue characterization. We have implemented DE-CT imaging with a preclinical dual source micro-CT scanner. With this configuration, both forward and cross-scatter can substantially degrade image quality. This work investigated the effect of scatter correction on the accuracy of post-reconstruction iodine and calcium decomposition. Scatter has been estimated using a lead beam stop technique. Our approach involves noise reduction in the scatter corrected images using bilateral filtering. The scatter correction has been quantitatively evaluated using phantom experiments and in vivo cancer imaging. As shown by our measurements, the dual source scanning is affected more by the cross-scatter from the high energy to the low energy imaging chain. The scatter correction reduced the presence of cupping artifacts and increased both the accuracy and precision of dual energy decompositions of calcium and iodine. On average, the root mean square errors in retrieving true iodine and calcium concentrations via dual energy were reduced by 32%. As a result of scatter corrections, we expect more accurate quantification of important vascular biomarkers such as fractional blood volume and vascular permeability in preclinical cancer studies.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
D. Clark, S. M. Johnston, G. A. Johnson, and C. T. Badea "The effect of cross-scatter correction on the performance of dual energy micro-CT", Proc. SPIE 8668, Medical Imaging 2013: Physics of Medical Imaging, 86684T (6 March 2013); https://doi.org/10.1117/12.2006904
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Calcium

Dual energy imaging

Iodine

Sensors

In vivo imaging

X-rays

Computed tomography

Back to Top