Paper
26 September 2013 Development of CCD cameras for soft x-ray imaging at the National Ignition Facility
A. T. Teruya, N. E. Palmer, M. B. Schneider, P. M. Bell, G. Sims, K. Toerne, K. Rodenburg, M. Croft, M. J. Haugh, M. R. Charest, E. D. Romano, K. D. Jacoby
Author Affiliations +
Abstract
The Static X-Ray Imager (SXI) is a National Ignition Facility (NIF) diagnostic that uses a CCDcamera to record timeintegrated X-ray images of target features such as the laser entrance hole of hohlraums. SXI has two dedicated positioners on the NIF target chamber for viewing thetarget from above and below, and the X-ray energies of interest are 870 eV for the “soft” channel and 3 – 5 keV for the “hard” channels. The original cameras utilize a large formatbackilluminated 2048 x 2048 CCD sensor with 24 micron pixels. Since the original sensor isno longer available, an effort was recently undertaken to build replacement cameras withsuitable new sensors. Three of the new cameras use a commercially available front-illuminatedCCD of similar size to the original, which has adequate sensitivity for the hard X-ray channelsbut not for the soft. For sensitivity below 1 keV, Lawrence Livermore National Laboratory (LLNL) had additional CCDs back-thinned andconverted to back-illumination for use in the other two new cameras. In this paper we describethe characteristics of the new cameras and present performance data (quantum efficiency, flat field, and dynamic range) for the front- and back-illuminated cameras, with comparisons to the originalcameras.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
A. T. Teruya, N. E. Palmer, M. B. Schneider, P. M. Bell, G. Sims, K. Toerne, K. Rodenburg, M. Croft, M. J. Haugh, M. R. Charest, E. D. Romano, and K. D. Jacoby "Development of CCD cameras for soft x-ray imaging at the National Ignition Facility", Proc. SPIE 8850, Target Diagnostics Physics and Engineering for Inertial Confinement Fusion II, 885008 (26 September 2013); https://doi.org/10.1117/12.2025051
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Cameras

X-rays

CCD cameras

Charge-coupled devices

Quantum efficiency

National Ignition Facility

X-ray imaging

RELATED CONTENT

Testing fully depleted CCD
Proceedings of SPIE (July 28 2014)
Off-plane x-ray grating spectrometer camera for IXO
Proceedings of SPIE (July 28 2010)
Status of the calibration of the EPIC pn camera onboard...
Proceedings of SPIE (February 03 2004)
36 cm2 large monolythic pn CCD detector for EPIC on...
Proceedings of SPIE (October 15 1997)
PN CCD detector for the European photon imaging camera on...
Proceedings of SPIE (October 31 1996)
PN CCD camera for XMM performance of high time...
Proceedings of SPIE (October 15 1997)

Back to Top