26 September 2013 Lifetime estimation of a time projection chamber x-ray polarimeter
Joanne E. Hill, J. Kevin Black, Lubos Brieda, Patsy L. Dickens, Kristina Montt de Garcia, Douglas L. Hawk, Asami Hayato, Keith Jahoda, Jelila Mohammed
Author Affiliations +
Abstract
The Gravity and Extreme Magnetism Small Explorer (GEMS) X-ray polarimeter Instrument (XPI) was designed to measure the polarization of 23 sources over the course of its 9 month mission. The XPI design consists of two telescopes each with a polarimeter assembly at the focus of a grazing incidence mirror. To make sensitive polarization measurements the GEMS Polarimeter Assembly (PA) employed a gas detection system based on a Time Projection Chamber (TPC) technique. Gas detectors are inherently at risk of degraded performance arising from contamination from outgassing of internal detector components or due to loss of gas. This paper describes the design and the materials used to build a prototype of the flight polarimeter with the required GEMS lifetime. We report the results from outgassing measurements of the polarimeter subassemblies and assemblies, enclosure seal tests, life tests, and performance tests that demonstrate that the GEMS lifetime is achievable. Finally we report performance measurements and the lifetime enhancement from the use of a getter.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Joanne E. Hill, J. Kevin Black, Lubos Brieda, Patsy L. Dickens, Kristina Montt de Garcia, Douglas L. Hawk, Asami Hayato, Keith Jahoda, and Jelila Mohammed "Lifetime estimation of a time projection chamber x-ray polarimeter", Proc. SPIE 8859, UV, X-Ray, and Gamma-Ray Space Instrumentation for Astronomy XVIII, 88590O (26 September 2013); https://doi.org/10.1117/12.2024724
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Polarimetry

Sensors

X-rays

Contamination

Polarization

Modulation

Copper

RELATED CONTENT

A possibility to extend the IXPE energy band
Proceedings of SPIE (August 31 2022)
Narrow-band x-ray polarizing filters
Proceedings of SPIE (September 13 2007)
Design and tests of the hard x ray polarimeter X...
Proceedings of SPIE (September 13 2011)
Performance of an Ar-DME imaging photoelectric polarimeter
Proceedings of SPIE (September 17 2012)

Back to Top