Paper
11 September 2013 Conceptual design of 1.5m aperture vertical collimator assembly with short tube and long focus
Fei Yang, Ming Ming, Fu-guo Wang, Li-min Zhang, Bao-gang Chen, Liang Shao
Author Affiliations +
Proceedings Volume 8907, International Symposium on Photoelectronic Detection and Imaging 2013: Infrared Imaging and Applications; 89071C (2013) https://doi.org/10.1117/12.2032307
Event: ISPDI 2013 - Fifth International Symposium on Photoelectronic Detection and Imaging, 2013, Beijing, China
Abstract
In order to evaluate and test the image quality of large aperture telescope, the most directly method is adopting the collimator and test the telescope system with full aperture. Changchun Institute of Optics, Fine Mechanics and Physics (CIOMP) commenced developing the large aperture collimator for interferometric and image quality testing of meter scale optical systems under cryogenic, vacuum conditions. The aperture of the collimator which has been on the conceptual design phase is 1.5m diameter, and the optical configuration is Cassegrain, the focus is 50m. The material of reaction bonded Silicon Carbide (RB-SiC) produced by CIOMP will be used as the primary mirror substrate. And the figure accuracy of the primary mirror will be polished better than 15nm (RMS). The collimator will be working in a vacuum chamber and face down vertically to the unit under test. The application requirements, specification requirements, and some key technology are demonstrated and analysed with finite element analysis (FEA) in the paper. The feasibility, error budget, and hazards evaluation of the collimator are fulfilled by the FEA results. It demonstrated that the conceptual design meet the requirements of the 1.5m aperture vertical collimator, and could achieve the high accuracy requirements of the wavefront for the beam of light in the vacuum chamber, which the wavefront error should less than 32nm(RMS). Mechanical alignment errors induced by thermal and structural perturbations are monitored with an auto-focusing system to enable focus compensation. The ambient temperature of the collimator in chamber are controlled allowing testing while the chamber shrouds and test unit are brought to cryogenic temperatures. With the high accuracy of the wavefront, the collimator could test the image resolution, modulation transfer functions (MTFs), point spread functions (PSFs), encircled energy, wavefront error, best focus, etc. for optical systems. And the conceptual design could be consulted to other large aperture collimators.
© (2013) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Fei Yang, Ming Ming, Fu-guo Wang, Li-min Zhang, Bao-gang Chen, and Liang Shao "Conceptual design of 1.5m aperture vertical collimator assembly with short tube and long focus", Proc. SPIE 8907, International Symposium on Photoelectronic Detection and Imaging 2013: Infrared Imaging and Applications, 89071C (11 September 2013); https://doi.org/10.1117/12.2032307
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Collimators

Mirrors

Wavefronts

Modulation transfer functions

Point spread functions

Cryogenics

Finite element methods

RELATED CONTENT


Back to Top