19 March 2014 Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation
Author Affiliations +
Abstract
Proper sizing of interventional devices to match coronary vessel dimensions improves procedural efficiency and therapeutic outcomes. We have developed a novel method using inverse geometry x-ray fluoroscopy to automatically determine vessel dimensions without the need for magnification calibration or optimal views. To validate this method in vivo, we compared results to intravascular ultrasound (IVUS) and coronary computed tomography angiography (CCTA) in a healthy porcine model. Coronary angiography was performed using Scanning-Beam Digital X-ray (SBDX), an inverse geometry fluoroscopy system that performs multiplane digital x-ray tomosynthesis in real time. From a single frame, 3D reconstruction of the arteries was performed by localizing the depth of vessel lumen edges. The 3D model was used to directly calculate length and to determine the best imaging plane to use for diameter measurements, where outof- plane blur was minimized and the known pixel spacing was used to obtain absolute vessel diameter. End-diastolic length and diameter measurements were compared to measurements from CCTA and IVUS, respectively. For vessel segment lengths measuring 6 mm to 73 mm by CCTA, the SBDX length error was -0.49 ± 1.76 mm (SBDX - CCTA, mean ± 1 SD). For vessel diameters measuring 2.1 mm to 3.6 mm by IVUS, the SBDX diameter error was 0.07 ± 0.27 mm (SBDX - minimum IVUS diameter, mean ± 1 SD). The in vivo agreement between SBDX-based vessel sizing and gold standard techniques supports the feasibility of calibration-free coronary vessel sizing using inverse geometry x-ray fluoroscopy.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Michael T. Tomkowiak, Amish N. Raval, Michael S. Van Lysel, Tobias Funk, and Michael A. Speidel "Calibration-free coronary artery measurements for interventional device sizing using inverse geometry x-ray fluoroscopy: in vivo validation", Proc. SPIE 9033, Medical Imaging 2014: Physics of Medical Imaging, 90332H (19 March 2014); https://doi.org/10.1117/12.2044078
Lens.org Logo
CITATIONS
Cited by 1 scholarly publication.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Intravascular ultrasound

Image segmentation

X-rays

Angiography

Arteries

Fluoroscopy

3D modeling

Back to Top