Paper
24 July 2014 The use of laterally graded multilayer mirrors for soft X-ray polarimetry
Herman L. Marshall, Norbert S. Schulz, David L. Windt, Eric M. Gullikson, Eric Blake, Dan Getty, Zane McInturff
Author Affiliations +
Abstract
ABSTRACT We present continued development of laterally graded multilayer mirrors (LGMLs) for a telescope design capable of measuring linear X-ray polarization over a broad spectral band. The multilayer-coated mirrors are used as Bragg re ectors at the Brewster angle. By matching to the dispersion of a spectrometer, one may take advantage of high multilayer re ectivities and achieve modulation factors over 50% over the entire 0.2-0.8 keV band. In Phase II of the polarimetry beam-line development, we demonstrated that the system provides 100% polarized X-rays at 0.525 keV (Marshall et al. 2013). Here, we present results from phase III of our development, where a LGML is used at the source and laterally manipulated in order to select and polarize X-rays from emission lines for a variety of source anodes. The beam-line will then provide the capability to test polarimeter components across the 0.15-0.70 keV band. We also present plans for a suborbital rocket experiment designed to detect a polarization level of better than 10% for an active galactic nucleus.
© (2014) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Herman L. Marshall, Norbert S. Schulz, David L. Windt, Eric M. Gullikson, Eric Blake, Dan Getty, and Zane McInturff "The use of laterally graded multilayer mirrors for soft X-ray polarimetry", Proc. SPIE 9144, Space Telescopes and Instrumentation 2014: Ultraviolet to Gamma Ray, 91441K (24 July 2014); https://doi.org/10.1117/12.2057003
Lens.org Logo
CITATIONS
Cited by 4 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Mirrors

X-rays

Polarimetry

Sensors

Charge-coupled devices

Polarization

X-ray sources

RELATED CONTENT

Progress toward a soft x-ray polarimeter
Proceedings of SPIE (September 26 2013)
The use of laterally graded multilayer mirrors for soft x...
Proceedings of SPIE (September 10 2015)
A soft x ray polarimeter designed for broadband x ray...
Proceedings of SPIE (September 20 2007)
Polarimetry with a soft x-ray spectrometer
Proceedings of SPIE (July 15 2008)
Soft x-ray polarimeter laboratory tests
Proceedings of SPIE (July 29 2010)

Back to Top