Paper
11 July 2016 Development of a pixelated CdTe detector module for a hard-x and gamma-ray imaging spectrometer application
J.-L. Galvèz, M. Hernanz, L. Álvarez, B. Artigues, J.-M. Álvarez, M. Ullán, M. Lozano, G. Pellegrini, E. Cabruja, R. Martínez, M. Chmeissani, C. Puigdengoles
Author Affiliations +
Abstract
Stellar explosions are relevant and interesting astrophysical phenomena. Since long ago we have been working on the characterization of novae and supernovae in X and gamma-rays, with the use of space missions. We have also been involved in feasibility studies of future instruments in the energy range from several keV up to a few MeV, in collaboration with other research institutes. High sensitivities are essential to perform detailed studies of cosmic explosions and cosmic accelerators, e.g., Supernovae and Classical Novae. In order to fulfil the combined requirement of high detection efficiency with good spatial and energy resolution, an initial module prototype based on CdTe pixel detectors is being developed. The detector dimensions are 12.5mm x 12.5mm x 2mm with a pixel pitch of 1mm x 1mm. Two kinds of CdTe pixel detectors with different contacts have been tested: ohmic and Schottky. Each pixel is bump bonded to a fanout board made of Sapphire substrate and routed to the corresponding input channel of the readout VATAGP7.1 ASIC, to measure pixel position and pulse height for each incident gamma-ray photon. The study is complemented by the simulation of the CdTe module performance using the GEANT 4 and MEGALIB tools, which will help us to optimise the detector design. We will report on the spectroscopy characterisation of the CdTe detector module as well as the study of charge sharing.
© (2016) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
J.-L. Galvèz, M. Hernanz, L. Álvarez, B. Artigues, J.-M. Álvarez, M. Ullán, M. Lozano, G. Pellegrini, E. Cabruja, R. Martínez, M. Chmeissani, and C. Puigdengoles "Development of a pixelated CdTe detector module for a hard-x and gamma-ray imaging spectrometer application", Proc. SPIE 9905, Space Telescopes and Instrumentation 2016: Ultraviolet to Gamma Ray, 99054B (11 July 2016); https://doi.org/10.1117/12.2231720
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Charge-coupled devices

Calibration

Bismuth

Sensors

Space operations

Observatories

X-rays

RELATED CONTENT

Fifteen years of the Advanced CCD Imaging Spectrometer
Proceedings of SPIE (July 24 2014)
The background properties of Suzaku/XIS
Proceedings of SPIE (June 15 2006)
Four years of operation of the Chandra X-Ray Observatory
Proceedings of SPIE (February 03 2004)
Long term trends in radiation damage of Chandra x ray...
Proceedings of SPIE (August 30 2005)

Back to Top