|
1.IntroductionThe trend in biomedical imaging is toward early detection and diagnosis of disease. Since virtually all disease originates at the molecular and cellular level, detection and imaging systems with resolutions and sensitivities capable of imaging at these levels would be most suitable. As such, optics has played a central role, providing not only sufficient resolution to resolve morphological features at the cellular level, but also wavelength sensitivity, which enables the detection and localization of the optical signal from spectroscopically specific endogenous molecules, transfected genetic sequences, or exogenous molecules or probes. The mere presence of spectroscopically identifiable probes, however, has limited informational content unless the presence can be linked to some physiologically or functionally meaningful parameter. By functionalizing and targeting probes to specific cellular and molecular sites, the detection and spatial localization of the probes through imaging techniques add molecular specificity. The potential of molecular optical imaging therefore becomes great, providing morphological, spatial, and functional information at the molecular level. While one may consider the historical and present use of stains and dyes in histology as a form of molecularly specific targeting with subsequent optical imaging, the field of molecular imaging has traditionally been defined as the detection of a molecularly specific signal, either from a targeted exogenous agent or some endogenous molecule, in a living organism. Under this definition, optical molecular imaging is still in its infancy but is rapidly expanding in scope through the use of new exogenous molecular probes and through the development of novel techniques for the detection of endogenous molecules. Figure 1 metaphorically diagrams the plethora of molecular probes, emitted optical signals, optical detection methods, and applications of optical molecular imaging. Numerous research studies have demonstrated the use of fluorescent markers tagged to a wide variety of specific cell receptors.1, 2, 3 The use of bioluminescent probes (luciferases) demonstrated optical molecular imaging in small animal models, primarily mice, and enabled the noninvasive detection of disease and tracking of progression in a wide range of pathologies and processes, including infection,4, 5 cancer,6, 7 and stem cell fates.8 The advancement of highly sensitive detection systems and cooled CCD cameras has permitted detection of extremely weak fluorescent and bioluminescent signals originating deep within highly scattering tissues.9 Recent efforts in the design of bioluminescent and fluorescent probes have been to extend the absorption and emission spectra of these probes into the near-infrared, where absorption and scattering can be minimized and depth of excitation and detection of emission can be maximized.10, 11 The majority of optical probes developed in recent years have been based on the emission of a bioluminescent or fluorescent signal. While these methods now have an established track record of use, there remains a number of other optical imaging methods that would equally benefit from novel optical probes to not only nonspecifically enhance contrast within images, but ultimately provide the same molecular specificity afforded by the bioluminescent and fluorescent probes (Fig. 1). A number of nonfluorescent detection and imaging techniques include in vivo video (white) light microscopy, reflectance confocal microscopy, and coherence imaging techniques such as optical coherence tomography (OCT). OCT is an emerging biomedical imaging technology that is based on the detection of backreflected signals using low-coherence interferometry and optical ranging within tissues.12, 13, 14 Because it senses elastically scattered light which maintains the coherence of the incident light, OCT is not capable of directly detecting bioluminescent or fluorescent signals. Despite the rapid development, application, and integration of OCT into the biological sciences, medicine, and surgery over the last decade, there has been little prior development and no regular use of contrast agents or molecular probes designed specifically for this modality. Early applications of OCT focused on the morphological imaging capabilities of this technology.15, 16, 17, 18, 19, 20 In recent years, attention has been given to the use of functional OCT techniques such as Doppler OCT,21, 22, 23, 24, 25 polarization-sensitive OCT,26, 27, 28, 29 and the detection of functional electrical activity in neural tissue,30, 31, 32 which provides additional information based on optical changes that correspond to physiological parameters. The coherence-imaging capabilities of OCT offer numerous advantages over fluorescence- and bioluminescence-based techniques, including heterodyne detection to improve signal to noise, and the ability to extract phase information from the detected signal, which permits velocimetric (Doppler) and spectroscopic imaging. With the advent of molecular contrast methods and molecular OCT imaging techniques,33 by way of the use of exogenous probes or contrast agents, or by the use of novel techniques to detect endogenous molecules, the imaging and diagnostic capabilities of OCT have the potential to be extended dramatically. Currently, new methods and classes of optical probes are being developed to enhance OCT contrast in unique ways, with the goal of enabling molecular OCT imaging. This work reviews the current research efforts in this area and describes future directions. While the majority of these research and development efforts have been directed toward OCT, similar probes and methodologies are applicable to other nonfluorescent optical imaging techniques, including reflectance confocal and white-light microscopy. 2.Probes for Coherence ImagingWhile the majority of molecularly targeted probes are based on fluorescence or bioluminescence, optical imaging technologies insensitive to inelastically scattered light must rely on other fundamental changes in optical properties, namely changes in scattering, absorption, polarization, or a time- or frequency-dependent modulation of amplitude, phase, or frequency of the light. Next, several classes of these probes are discussed. 2.1.Scattering ProbesProbes designed for efficient light scattering are sensed either directly by detecting their scattered light or indirectly through their attenuation of the incident light. Imaging modalities such as OCT are based on detecting backscattering and operate in the “biological window” of near-infrared wavelengths where absorption is minimal and attenuation is governed primarily by scattering. To alter the intensity of backscattered light in OCT, scattering probes must introduce a local region of index of refraction change. For instance, even the introduction of air into tissue produces a significant change in index, thereby increasing the intensity of the backscattered light in OCT. One of the first demonstrations of scattering probes was the use of gold nanoparticles in electron microscopy to label specific regions within cells.34 Commercially available air-filled (Albunex®) and perfluorocarbon-filled albumin microspheres for use as contrast-enhancing agents in ultrasound35 were also used to enhance optical contrast in OCT.36 With recent advances in sonochemistry and chemical modification of probes, a wide variety of engineered microspheres have been fabricated to optimize the optical scattering properties of these probes (Fig. 2 and Table 1 ).37 Scattering microspheres were fabricated using a high-frequency ultrasound probe placed at the interface between liquids where high-energy ultrasound waves produce cavitation and microsphere formation. Microspheres in diameter could be fabricated by varying the energy used during sonication. This fabrication protocol enables a wide range of flexibility in combining core, shell, and surface composition as listed in Table 1. Since scattering increases with the magnitude of the refractive index change, the use of metals or other materials with an index significantly different from tissue is desirable. Quantitative analysis of optical absorption and scattering properties of engineered microspheres have demonstrated that the use of highly scattering nanoparticles of gold, melanin, carbon, and iron oxide produce strong scattering in OCT (Fig. 2).37 Table 1Engineered microsphere core, shell, and surface combinations.
These engineered protein microspheres have been demonstrated in in vivo OCT imaging in animal models. Figure 3 shows representative images of exposed mouse liver before and after the tail-vein injection of gold-coated protein microspheres.37 The administration of the nontargeted scattering microspheres increased the scattering from the liver, while revealing low signal from the liver vasculature. The primary mechanism of uptake in the liver was via phagocytosis by the resident macrophages (Kuppfer cells). Scanning electron micrographs of macrophages (Fig. 3) with and without exposure to microspheres show clearly that the microspheres are readily phagocytosed and broken down within these cells. Early in vitro cell viability studies have shown that these engineered microspheres have little to no cellular toxicity.38 The administration of these engineered microspheres does provide dynamic scattering changes within tissue. Following mouse tail-vein injection of iron-oxide encapsulated microspheres, transient regional scattering changes were observed while imaging the exposed mouse intestinal wall (Fig. 4 ). Scattering variations were noted around a vascular region, while minimal changes were observed in an avascular region immediately after the administration of the agents. While the larger microspheres are likely to remain in the vascular system due to their size, it remains to be determined if the observed scattering changes were due to extravasation of smaller microspheres, degraded microsphere fragments, or a local accumulation of microspheres within the vascular system. In addition to the flexibility of altering the scattering properties (and equally the absorption properties) of these microspheres, the potential exists for these probes to be highly multifunctional. The protein-based shell of these microspheres is readily functionalized, as has been demonstrated in ultrasound imaging.39 With the increasing number of viable molecular targets available, such as the overexpression of cell-surface receptors in disease states like cancer, it will be possible to similarly target these microspheres to molecularly specific sites. The physical size of these microspheres ( average) prohibits their use as an agent that will extravasate from the intravascular space into the extravascular and extracellular spaces for cell-specific targeting. Their use as a blood pool agent would be feasible for defining vascular networks, identifying regions of altered perfusion, or for labeling regions of vessels expressing specific markers during diseases such as angiogenesis and atherosclerosis. However, their relatively large size is fortuitous as a drug delivery vehicle by encapsulating drugs that can be delivered to specific sites. The engineered scattering microsphere enables the fabrication of a scattering probe that uses selected nanoparticles spatially oriented on the microsphere shell, or within the core material to optimize the scattering cross section, whereby the use of nanoparticles alone, although smaller in size, is not likely to alter the local scattering property of the tissue as strongly. The use of scattering nanoparticles alone, without attachment to larger microspheres, would be preferred for their small size, their ready ability to extravasate outside of the vascular system, and the potential to be directed toward individual cells. The highly scattering (plasmon-resonant) nature of gold nanoparticles was used to label individual cells expressing specific cell-surface receptors.40, 41 Gold nanoparticles were conjugated to an anti-epithelium growth factor receptor (EGFR) and incubated with SiHa cells (Fig. 5 ). These highly scattering gold nanoparticles, depending on their size, aggregation, and local environment, potentially exhibit surface plasmon resonances, which are an additional class of OCT contrast agents discussed in a later section. When viewed with reflectance confocal microscopy and compared to transmission-mode microscopy, site-specific contrast enhancement was observed. 2.2.Modulating ProbesIn OCT, sensing a change in local scattering induced by a probe is frequently plagued by speckle and background scattering from the tissue medium. Higher probe imaging specificity may be achieved by modifying an observable property of the probe in situ while leaving the background tissue unperturbed. Modulation and subsequent filtering of the signal results in background rejection of unperturbed tissue structures, analogous to the background reduction leveraged by the use of fluorescent probes. Recently, optical contrast agents with modulatable fluorescence have been developed that enable the rejection of stationary background signals. Fluorescent microspheres with a ferromagnetic core were coated on one hemisphere with a metal, then magnetized. The microspheres were rotated using a rotating magnetic field, resulting in modulation of their fluorescence emission.42 The magnetically induced blinking drastically improved the detection sensitivity of these agents in fluorescence microscopy. For OCT, modulating probes have been investigated primarily along two channels: modifiable scattering using magnetic particles, and modifiable absorption using dye molecules. Discussion of the latter is postponed to the following section on absorbing probes. The use of particles with high magnetic susceptibility and/or ferromagnetic property is highly desirable, because tissue exhibits no ferromagnetism and only weak magnetic susceptibility . Iron oxide such as magnetite is a good candidate due to its known biocompatibility after polymer coating. In the presence of a high magnetic field gradient, particles with high magnetic susceptibility embedded in tissue experience a gradient force, and ferromagnetic particles rotate to align their internal magnetization along the field.43 The resulting magnetomotion of the particle and perturbation of the surrounding cells and organelles result in a change in the local scattering (Fig. 6 , top panels). In an elastic medium, the particle returns to its original position and orientation after removal of the magnetic field. This permits modulation of its position by repetitively modifying the magnetic field (by toggling it on and off in the examples discussed here). Modulation at any frequency outside the bandwidth of the OCT backscattering signal allows differentiation of tissue structure from magnetic particles.44 In practice, this has been performed by toggling power to an electromagnet between each successive axial OCT scan (Fig. 6, bottom panels), or by modulating the power several times during acquisition of each pixel and using lock-in detection.45 In a recent study,46 macrophage cell labeling in tissue scaffolds using magnetic markers and magnetomotive OCT was demonstrated (Fig. 7 ). The ability to detect magnetic particles attached to cells and inside highly scattering media such as chicken skin (Fig. 8 ) suggests future potential for this technique in vivo. A promising avenue of probe development is protein microspheres that incorporate iron-oxide nanoparticles either as an encapsulated ferrofluid or embedded into the protein shell (Fig. 2). Recent advances in biomedicine that utilize superparamagnetic and ferromagnetic particles, such as for hyperthermic therapy,47 magnetorelaxometry,48 magnetic drug targeting,49 and magnetic resonance (MR) molecular contrast imaging,50 suggest a wide array of possible translational applications in conjunction with magnetomotive OCT. Of particular interest is the development of multimodal targeted magnetic probes, which are identified at the mesoscopic scale using magnetic resonance imaging (MRI) and subsequently localized at the microscopic scale using high-resolution, small field-of-view techniques such as OCT to provide intraoperative surgical guidance. 2.3.Absorbing ProbesThe use of absorbing probes for OCT is based on the regional attenuation due to the absorption. For homogeneous tissue, this regional attenuation can be detected as the reduced backscattering intensity in the deeper structures. However, because biological tissue is inhomogeneous, the scattering efficiency varies considerably for different layers. The detection of absorbing probes based on intensity attenuation alone is usually not accurate. Therefore, spectrally uniform absorbing agents, such as ink or broadband dye, have little value in OCT. However, two approaches can drastically improve the detection accuracy. The first approach is to utilize the fact that some absorbing probes absorb light differently for different wavelengths. Spectroscopic analysis of the light affected by these probes can drastically improve the detection accuracy. An intuitive way to understand this is to consider the less absorbing frequency bands as the built-in control for the more absorbing frequency bands. Hence, the difference in tissue scattering efficiency can be normalized to some degree. The second approach utilizes absorbers that have modifiable absorption in the presence of optical pumping. By turning the optical pumping on or off, background rejection can be achieved through differencing of pairs of images obtained while the agent property was changed. Examples of the two approaches will be described in this section. A more detailed description of spectroscopic OCT (SOCT) measurement techniques and algorithms, which can be used to detect absorbing probes, is presented in a later section. Within the broadband laser spectra offered by state-of-the-art femtosecond titanium:sapphire lasers (centered at ), none of the major molecular components of tissue, namely water, structural proteins without chromophores, most carbohydrates, lipids, and nucleic acids, are spectrally active. For this reason, anatomical and biochemical research using SOCT to date has been limited to a few types of naturally occurring NIR absorbers such as deoxy- and oxy-hemoglobin and melanin, with studies done in vitro.51 This situation is very similar to conventional light microscopy imaging, where most tissue structures are colorless without the use of specific stains. It is therefore intuitive that “spectroscopic staining,” with the use of dyes that are spectrally active in the NIR region, will enhance contrast in SOCT and potentially aid in differentiating tissue structures. The simplest spectroscopic absorbing probes are the NIR dyes;1, 3, 52 however, plasmon-resonant nanoparticles are also strongly absorbing in the NIR, with tunable peak absorption spectra and bandwidth. To facilitate spectroscopic OCT detection, it is desirable for NIR dyes or plasmon-resonant nanoparticles to have sharp, distinct, and stable absorption peaks within the OCT laser spectrum for more accurate labeling. Many commercially available fluorescence dyes, laser dyes, and optimized plasmon-resonant nanoparticles (spheres, shells, rods, cages) can be used for this purpose. In one example, the Federal Drug Administration (FDA)-approved NIR dye indocyanine green (ICG) has an absorption peak in and a full width at half maximum (FWHM) of , and was used in several studies.53 While ICG has an absorption peak near the center wavelength of the Ti:sapphire laser spectrum, it is frequently advantageous to have an absorber that has an absorption peak off-center to enhance the spectroscopic contrast and the OCT imaging depth. For example, in a recent study, a NIR dye with strong absorption over the shorter half of the laser spectrum was used (Fig. 9 ). SOCT analysis was able to localize the dye distribution in the vascular system of a botanical specimen.54 The first experimentally demonstrated molecule with modifiable absorption in OCT was methylene blue,55 which can be excited from its ground state (absorption peak at ) to its excited state (absorption peak at ) by using optical excitation. Therefore, by switching optical excitation on and off, the absorption property at 830 can be modulated (Fig. 10 ). Because methylene blue has a rather short excitation state lifetime, a high pumping intensity was required. Other molecules with more stable excited molecular states were investigated to reduce the requirement in the pumping power. Phytochrome A, a naturally occurring plant protein with two distinct states of different absorption, was identified as a potential agent because one of its peak absorption states is in the commonly used OCT spectral range of the Ti:sapphire laser, and has very long transition durations on the order of a second (Fig. 11 ).56 2.4.Plasmon-Resonant ProbesBecause Rayleigh scattering theory predicts that the scattering cross section scales as the sixth power of the particle diameter, it becomes increasingly difficult to achieve smaller, nanosize probes with sufficient cross section to be detected with OCT at concentrations that are nontoxic. To overcome this limitation, there has been extensive interest in the use of metal nanoparticles that exhibit a collective excitation of electrons at a characteristic light frequency, a property called the surface plasmon resonance (SPR).57 At optical wavelengths, this is primarily observable in silver and gold, the latter being particularly useful in the near-infrared. A variety of SPR nanoparticle geometries are currently under investigation as optical probes, including nanospheres,58 nanoshells,59 nanorods,60 and nanocages.61 Because the resonance frequency is governed by particle geometry and the response exhibits an extremely narrow spectral linewidth, the possibility exists for multichannel imaging using an array of multitargeted probes whose resonance frequency is associated with a specific cell receptor.62 However, the linewidth is often limited in practice by the ability to synthesize batches that are extremely monodisperse in size, and for gold nanoshells, other physical limitations to the linewidth have also been identified.63 Recently, gold nanoparticles targeted against the epidermal growth factor receptor (EGFR) have been used as highly scattering agents for molecular sensitivity with structured illumination light microscopy.64 Similarly, SPR nanoparticles are of interest in OCT because their small size enables extravasation from circulation into the extravascular space. Plasmon-resonant nanoshell probes consist of a metal shell (Ag or Au) grown over a solid dielectric core (typically ). This geometry increases the magnitude of the local electromagnetic field at the nanoparticle surface, resulting in measured field enhancements of and an implied enhancement of (Ref. 65). The resonance frequency is tuned by adjusting the core/shell size ratio,66 and the albedo (relative contribution of scattering compared to absorption) is also variable based on particle geometry and can be tailored to match the application.59 Highly scattering nanoshells labeled with the HER-2 antibody have been shown to target breast cancer cells as imaged with darkfield microscopy,59 and also display a detectible signal when imaged with OCT. In a separate application, absorbing nanoshells increase photodamage induced by NIR illumination, as shown in an animal tumor model.67 Rod-shaped gold nanoparticles known as nanorods [Fig. 12(a) ] are of considerable interest due to their unique spectral response consisting of a transverse plasmon resonance and a longer wavelength longitudinal plasmon resonance. The center wavelength of the longitudinal plasmon resonance increases nearly linearly with the aspect ratio of the rod,68 and reaches near-infrared wavelengths with easily achieved aspect ratios greater than 3:1. Because nanorods with typical dimensions less than are primarily absorbers,60, 69 they are detectible by OCT through their depth-dependent attenuation, resulting in a sensitivity of of nanorods within a tissue-like scattering solution.60 This sensitivity is expected to increase with the use of spectroscopic-specific detection as described earlier. In particular, nanorods with a longitudinal plasmon resonance tuned to and a narrow linewidth of have been detected with an OCT system utilizing a Ti:sapphire source (Fig. 12). SOCT has been able to extract the absorption spectra of these nanorods with good agreement to spectrometer measurements. The presence of these nanorods results in attenuation of approximately half the OCT incident light bandwidth and a depth-dependent shift of the backscattered light spectrum. Another intriguing nanoparticle geometry is that of the nanocage,61 essentially a hollowed gold cube with porous walls, which, for nominal dimensions of , exhibits a SPR near . These nanocages are also primarily absorbers, and OCT imaging demonstrates detection at in tissue phantoms. Bioconjugation of nanocages to HER-2 and specificity to breast cancer cells [visualized by scanning electron microscope (SEM)] has also been demonstrated.61 It should also be noted that, to date, both nanocages and nanorods are significantly smaller than the nanoshells currently used for OCT imaging. Further studies are required to determine what specific role the size of these nanoparticles plays in allowing them to extravasate out of the vasculature and into the extravascular space for in vivo cell targeting. In conclusion, SPR particles afford a large optical cross section while maintaining a small physical size to enable high tissue mobility. Future work to improve the sensitivity of OCT to SPR particles may include polarization-sensitive detection of anisotropic particles, or coupling the particles with a magnetic domain to allow in situ modulation. The current state of the art includes the ability to separately target, image, and photothermally damage cancerous cells, suggesting that it may not be far in the future when each of these goals is obtained simultaneously using a single probe platform. 3.Molecular OCT Imaging of Endogenous MoleculesThe previous methods of contrast in OCT depend on introducing an exogenous contrast agent into the tissue. Exogenous agents must be biocompatible, produce a sufficiently strong scattering or absorption signature to be detectable, and be specific to a molecular or cellular feature of interest. An alternate approach is to use the molecules of interest themselves as contrast agents, so that no foreign agents or probes need to be introduced. There are a number of molecular OCT imaging techniques that generate contrast from endogenous molecules present in the specimen. It should also be noted that the techniques discussed in the section could also be coupled with exogenous probes that may contain a more specific signature. 3.1.Spectroscopic Optical Coherence TomographySpectroscopic OCT analyzes not only the intensity, but also the spectrum of backscattered light in a spatially resolved manner. SOCT techniques are possible largely because OCT utilizes broadband laser sources. Hence, the spectroscopic features within the laser spectrum can be detected. SOCT techniques are algorithmic, do not require special OCT imaging hardware, and can be implemented using either a time-domain or a spectral-domain OCT system.70, 71, 72 Because the spectra of backscattered light are depth varying along the imaging axis, SOCT signals are nonstationary, with both time (depth) and frequency (wavelength) variations. Therefore, the central signal-processing step in SOCT analysis is to obtain the time-frequency analysis from the time-dependent interferogram signal (for a time-domain OCT system), or the frequency-dependent interferogram signal (for a spectral-domain OCT system). From the time-frequency analysis, different tissue properties can be retrieved. The time-frequency analysis of the SOCT signal suffers the so-called time-frequency “uncertainty principle,” which states that there exists an inherent tradeoff between spectral resolution and time (spatial) resolution.73 Improvement in one implies degradation in the other. Early SOCT studies used linear time-frequency analysis methods such as the short time Fourier transform (STFT) and the wavelet transform.70 Different time resolution and frequency resolution can be achieved by using time windows of different length (or wavelets of different scaling). In an effort to improve the joint time-frequency resolution, higher order transformations, such as the Wigner’s distribution, can be used.74 In general, it was determined that different SOCT imaging scenarios require different optimal time-frequency analysis methods.73 For instance, the Cohen’s-class time-frequency analysis generates the most compact time-frequency analysis, while linear time-frequency analysis offers the most reliable time-frequency analysis.75 In both cases, if some prior information is known about the tissue, the molecules of interest, or perhaps the optical properties of an exogenous probe, model-based time-frequency analysis can increase performance. Typically, there are two spectral modification processes: spectral absorption and spectral scattering. Both processes can be present in the tissue at the same time. Therefore, it is important for SOCT to separate the contributions from each of them. The number of the spectral bands analyzed by SOCT is often more than the number of spectral modification processes of interest; the separation is a mathematical overcomplete problem and can be obtained by spectral analysis. The first such attempt was through spectral triangulation,53 which uses three probe lasers of equally spaced center wavelengths. Spectral triangulation was capable of separating the intrinsic first-order spectral scattering from the extrinsic dye absorption, and this technique was demonstrated with the use of ICG in a Xenopus laevis (African frog) tadpole (Fig. 13 ). A more sophisticated approach utilizes the least-squares fitting algorithms.76 Compared to spectral triangulation, the least-squares fitting algorithm utilizes more frequency bands and is optimal for most practical problems. In principle, SOCT can be used to map out absorbing probes or molecules such as , melanin, and other endogenous chromophores. Among them, is especially interesting because of their abundance and their critically important role as indicators of tissue oxygenation states. Currently, two prominent methods for in vivo mapping of are functional magnetic resonance imaging (fMRI)77 and NIR optical tomography.78 However, fMRI suffers from low temporal resolution and NIR optical tomography suffers from low spatial resolution. SOCT theoretically can overcome both drawbacks with real-time OCT imaging with micrometer resolution. However, due to the time-frequency tradeoff problem mentioned before, the spatial resolution that can be achieved ultimately is dependent on the system sensitivity and noise reduction. In an early report, the oxygenation states of were distinguished by SOCT with spectral resolution and spatial resolution.51 As a method for detecting and imaging not only endogenous molecular species but also exogenous probes, research in the use of SOCT will continue to define its applications and limitations. 3.2.Molecular Contrast through Nonlinear InterferometryTypical OCT methods measure the linear, elastic scattering of tissues, which are limited to the detection of scattering, absorption, spectral, and polarization properties inside the illumination bandwidth. Unfortunately, most molecules of interest do not have distinct scattering signatures in the near-infrared wavelengths commonly used in OCT. However, there are many nonlinear optical effects that biomolecules exhibit that can be used for molecular contrast. Nonlinear effects, including second harmonic generation (SHG)79, 80, 81, 82, 83 and coherent anti-Stokes Raman scattering (CARS),84, 85, 86, 87, 88, 89, 90, 91 have recently been successfully integrated with OCT to produce images with endogenous molecular contrast.92, 93, 94, 95 Unlike linear scattering, where individual photons independently scatter off of the sample, several photons mutually interact through the sample in nonlinear scattering processes. The incident photons are selected to promote a particular nonlinear process that produces molecular contrast. To interact at a particular point in the tissue, the interacting photons must, roughly speaking, arrive at the same place at the same time. Pulsed lasers are typically used to concentrate the photons into a small enough time interval, and focused beams are used to concentrate the photons into a small enough spatial extent, to produce a measurable nonlinear signal. Only certain nonlinear processes are suited for nonlinear interferometry. The scattered radiation must remain coherent with the illumination, which excludes effects such as spontaneous fluorescence and spontaneous Raman scattering. It is also desirable for the scattered radiation to be of a different frequency bandwidth than the incident radiation, so that the scattered radiation is easy to distinguish from the incident radiation. Because nonlinear processes are generally weak, any background signal can easily overwhelm the small nonlinear signal. Two nonlinear processes that satisfy the criteria for detection with nonlinear interferometry are SHG and CARS. Each of these processes provides differing information on the composition of tissue. A representative schematic of how nonlinear interferometry can be integrated into OCT is shown in Fig. 14 . A pulsed source produces the optical frequencies needed to stimulate the nonlinear process. This source is split between the two arms of an interferometer. In the sample arm, a pulse shaper is used to control the temporal profile of the pulse to excite a particular nonlinear process of interest. The shaped pulse is then focused into the sample, where the target molecular species will convert some of the radiation to a nonlinear signal. The backscattered signal from the sample is then filtered for the remaining excitation radiation. In the reference arm, a nonlinear reference generator, which can consist of the molecular species being imaged or a nonlinear crystal, converts some of the excitation wavelengths to the nonlinear band. The two nonlinear signals are combined with a beamsplitter, and the interference is measured as the relative time delay is scanned. The amplitude of the interference fringes indicates the density of the target molecular species. Using interferometric detection of a nonlinear process itself has benefits over standard incoherent nonlinear microscopy such as SHG or CARS microscopy. OCT coherence gating can be performed on the returned nonlinear signal to range the depth of nonlinear scatterers in tissue. In nonlinear microscopy, the focus is scanned through the sample, because the nonlinear process itself limits the volume over which the interaction occurs. Interferometric detection also provides the heterodyne advantage, where the interference component of the signal may be increased until the signal-to-noise ratio is limited only by the available signal from the sample and not detector noise. Heterodyning also minimizes the noise caused by stray light. Finally, dual balancing or spectral interferometry can be used to minimize the effects of power fluctuations in the pulsed source. Second harmonic generation is an effect where a nonlinear material will convert two photons of one frequency to a single photon of twice the frequency. Because of the symmetry of the process, SHG does not occur in a uniform, isotropic medium. SHG is generally produced at surfaces, in birefringent media, or by asymmetric structures such as rod-like or fiber-like structures. The SHG process can then better discriminate between uniform media, anisotropic structures produced by cell membranes, and commonly, collagen fibers. For example, SH-OCT has been proposed and demonstrated on collagen layers (Fig. 15 ).81 Another method of nonlinear contrast utilizes CARS, and is called nonlinear interferometric vibrational imaging (NIVI).92 Raman scattering probes the vibrational resonance frequencies of molecules. Unlike other methods such as infrared spectroscopy, Raman scattering is a nonlinear process that can utilize wavelengths of in the biological window that are not absorbed by tissues. CARS is often used in microscopy instead of the more common spontaneous Raman scattering, because CARS produces a much stronger signal. Incoherent detection of CARS has been used in a manner analogous to two-photon microscopy to image biological tissues.84, 85, 86, 87, 88, 89, 90, 91 Using OCT optical ranging and interferometry techniques improves on these methods by taking advantage of the coherent nature of CARS, increasing the sensitivity, rejecting noise, and allowing the temporal ranging of the CARS signal. The coherence gating and spatial localization of CARS signals has been demonstrated (Fig. 16 ), and is likely to provide an alternate method of locating molecular species in tissues.93 In particular, NIVI92 has been developed to allow the amplitude and phase of the nonlinear susceptibility to be inferred. This helps remove artifacts due to nonresonant processes that are not specific to the molecular frequencies of interest. These processes can dominate the nonlinear signal and therefore greatly reduce the molecular specificity of the method if they are not removed. The elimination of these nonresonant components was demonstrated94 by coherence gating the CARS signal to exclude the nonresonant component. The interferometric reconstruction of the amplitude and phase of the Raman spectrum has been achieved95 and has greatly increased confidence that further enhancements of the use of CARS in OCT will result in high fidelity images. As the techniques of ultrafast signal production and detection are refined, it seems likely that other coherent nonlinear processes will also be exploited to provide further molecular specificity. 4.Future Directions and ChallengesThe recent advances and successes in the use of bioluminescent and targeted fluorescent probes have clearly established the use of optical molecular imaging for elucidating the pathogenesis of disease in preclinical animal models. Similarly, it is expected that advances in the development and use of molecular imaging probes for nonfluorescence- and nonbioluminescence-based optical imaging modalities such as OCT, light microscopy, and reflectance confocal microscopy will have an equally significant impact. Several active areas of research include targeting of probes, the development of externally and physiologically activatable probes, and the imaging of genetically engineered and expressed probes. The ability to target molecular probes to site-specific cells or tissues not only has significant implications for enhancing image contrast and visualization, but also, and perhaps more importantly, enables the site-specific delivery of pharmacotherapeutics for treating the disease. Despite the advancements made in this area over decades of research, our ability to target a particular cell type with sufficient specificity remains relatively poor. However, there have been several commonly identified targets, including the folate receptor, which is expressed in normally low levels in adult tissues, but overexpressed in proliferating malignant cells,96 and the sigma receptor, which can be highly overexpressed (up to ten-fold) in a variety of tumors including lung, renal, colon, central nervous system, breast, prostate, and melanoma.97 Much of these limitations arise from our limited understanding of the molecular and cellular events occurring in vivo in these disease states, and the relatively small differences between target expression profiles on normal and abnormal cells. Given the intense scientific, medical, and economical incentives for advancing this research, our ability to target, image, and treat specific cells of interest will likely continue to improve over time. The striking ability of optical techniques to image extremely weak optical signals is most appreciated with background rejection techniques, where the nonspecific optical signal is separable from the signal arising specifically from the contrast agents. Bioluminescence imaging is an excellent example, as are fluorescence-based confocal and multiphoton methods in the absence of autofluorescence. Of the methods and probes discussed in this work, the use of magnetomotive OCT and pump-probe OCT exhibit high degrees of background rejection, which can provide higher signal to noise than other techniques (such as those that rely simply on the addition of a strong scatterer or absorber to tissue). Classes of probes that would enable high specificity of detection are those that can be activated, either through some external trigger or internally, through some physiological process. The former method was demonstrated using a pump-probe OCT technique with probes that have varying absorption states.55, 56 The use of the latter method would enable a wide range of functional studies that could investigate physiological states and processes in vivo and in real time. While molecular beacons98, 99 and protease-activatable fluorescence probes100 represent examples of this class of probes, the development of these physiologically activatable probes for OCT remains an active area of research. Green fluorescent protein (GFP), its many variants, and other genetically encoded light-emitting proteins have expanded our ability to visualize biology in normal and diseased states.101 It is also well recognized in the biomedical optics communities that there is a need for longer-wavelength probes in the near-infrared to reduce tissue damage and to increase imaging depth in highly scattering tissues. Recently, the DsRed protein, with longer-wavelength absorption and emission spectra, has been imaged using OCT in a pump-probe configuration.102 This demonstration represents an important step in the use of genetically expressed probes in conjunction with OCT. Because of the imaging-depth penetration advantage that OCT provides over more traditional fluorescence-based microscopy methods, and the high spatial resolution advantage over bioluminescence-based imaging, the development of genetically expressed probes for OCT will likely expand the toolkit of investigational methods. Naturally occurring substances such as melanin, with its high refractive index , may offer another alternative.103 In all of these cases, genetically expressing molecules that exhibit strong and modifiable scattering or absorbing properties detectable with molecular OCT techniques would further advance this field. Recent advances in the development of molecular probes and techniques for OCT are accompanied with multiple challenges and limitations. Fundamental studies need to be completed that would fully characterize the optical properties of these probes in phantoms, cell culture, and in tissue, as well as under normal and pathologic conditions. Critical investigational studies are needed to determine the detection sensitivity and establish the limits to which these methods would be used for detecting at the cellular and molecular level, both in cell cultures and in animal models. As one would anticipate, higher concentrations of probes would generate stronger signals, yet careful in vitro and in vivo studies remain to be completed to determine the toxicity of these probes and the optical radiation used for their detection and imaging. To our advantage, many similar probes, such as albumin microspheres, iron oxides, absorbing molecules, and gold nanoparticles, are currently being used for molecular imaging techniques in other modalities including MRI and ultrasound. Additionally, many similar classes of probes suitable for use in OCT have been approved by the U.S. Federal Drug Administration such as Albunex®,35 Feridex®,104 and indocyanine green (ICG) dye,105 to name a few. Finally, more quantitative studies are needed in normal and tumor animal models to both demonstrate the enhancement of contrast with these probes, and ultimately to show their use for improving our clinical diagnostic ability. Ideally, one would like to perform optical molecular imaging without the need of exogenous agents that could potentially induce toxicity or alter the physiology of the process one is wishing to measure. Optical methods, such as SOCT or NIVI, may in time be able to characterize the molecular composition of tissue with high sensitivity and specificity only by detecting variations from the incident optical radiation, and may ultimately prove to be most desirable. While the development and experimental implementation of optical probes for OCT is still in its infancy, it is clear that the use of novel probes or contrast agents in OCT will enable OCT to progress to a new diagnostic level. Early applications of OCT focused on the morphological imaging capabilities of this technique. In recent years, attention has been given to the use of functional OCT techniques that provide additional information based on optical changes that correspond to physiological parameters. With the advent of molecular OCT imaging techniques, by use of exogenous probes or contrast agents, or by use of novel techniques to detect endogenous molecules, the imaging and diagnostic capabilities of OCT will be extended significantly. Ultimately, the task for the OCT community will be to demonstrate the clinical efficacy and improvement in diagnostic ability afforded by these emerging molecular OCT imaging techniques. AcknowledgmentsWe wish to thank the members of the Biophotonics Imaging Laboratory at the Beckman Institute on the University of Illinois at Urbana-Champaign (UIUC) campus for their dedication and insight in this area of research. We also wish to thank our collaborators for their work in fabricating novel probes, including Kenneth Suslick, Department of Chemistry, UIUC, Kenneth Watkin, Department of Speech and Hearing Sciences, UIUC, and Alex Wei, Department of Chemistry, Purdue University, and appreciate the assistance of Janet Hanlon in preparing these figures. Finally, we thank our colleagues whose work is represented here for helping advance this field, and apologize to those whose work was not included due to space and depth of coverage constraints. This research was supported in part by The Whitaker Foundation (RG-01-0179, S.A.B.), the National Institutes of Health (NIBIB, 1 R01 EB-00-108, 1 R01 EB-03-003, S.A.B.), NCI/NASA (NAS2-02057, S.A.B.), and the Beckman Institute for Advanced Science and Technology. Additional information can be found at http://biophotonics.uiuc.edu. ReferencesS. Achilefu,
R. B. Dorshow,
J. E. Bugaj,
R. Rajagopalan,
“Novel receptor-targeted fluorescent contrast agents for in vivo tumor imaging,”
Invest. Radiol., 35 479
–485
(2000). https://doi.org/10.1097/00004424-200008000-00004 0020-9996 Google Scholar
R. Weissleder and
V. Ntziachristos,
“Shedding light onto live molecular targets,”
Nat. Med., 9 123
–128
(2003). https://doi.org/10.1038/nm0103-123 1078-8956 Google Scholar
S. Achilefu,
“Lighting up tumors with receptor-specific optical molecular probes,”
Technol. Cancer Res. Treat., 3 393
–409
(2004). 1533-0346 Google Scholar
T. C. Doyle,
S. M. Burns, and
C. H. Contag,
“In vivo bioluminescence imaging for integrated studies of infection,”
Cell. Microbiol., 6 303
–317
(2004). 1462-5814 Google Scholar
M. R. Hamblin,
T. Zahra,
C. H. Contag,
A. T. McManus, and
T. Hasan,
“Optical monitoring and treatment of potentially lethal wound infections in vivo,”
J. Infect. Dis., 187 1717
–1725
(2003). 0022-1899 Google Scholar
S. Gross and
D. Piwnica-Worms,
“Spying on cancer: molecular imaging in vivo with genetically encoded reporters,”
Cancer Cells, 7 5
–15
(2005). 1042-2196 Google Scholar
A. Rehemtulla,
L. D. Stegman,
S. J. Cardozo,
S. Gupta,
D. E. Hall,
C. H. Contag, and
B. D. Ross,
“Rapid and quantitative assessment of cancer treatment response using in vivo bioluminescence imaging,”
Neoplasia, 2 491
–495
(2000). https://doi.org/10.1038/sj/neo/7900121 1522-8002 Google Scholar
X. Wang,
M. Rosol,
S. Ge,
D. Peterson,
G. McNamara,
H. Pollack,
D. B. Kohn,
M. D. Nelson, and
G. M. Crooks,
“Dynamic tracking of human hematopoietic stem cell engraftment using in vivo bioluminescence imaging,”
Blood, 102 3478
–3482
(2003). https://doi.org/10.1182/blood-2003-05-1432 0006-4971 Google Scholar
B. W. Rice,
M. D. Cable,
M. B. Nelson,
“In vivo imaging of light-emitting probes,”
J. Biomed. Opt., 6 432
–440
(2001). https://doi.org/10.1117/1.1413210 1083-3668 Google Scholar
J. E. Bugaj,
S. Achilefu,
R. B. Dorshow, and
R. Rajagopalan,
“Novel fluorescent contrast agents for optical imaging of in vivo tumors based on a receptor-targeted dye-peptide conjugate platform,”
J. Biomed. Opt., 6
(2), 122
–133
(2001). https://doi.org/10.1117/1.1352748 1083-3668 Google Scholar
S. Stoyanov,
“Probes: dyes fluorescing in the NIR region,”
Near-Infrared Applications in Biotechnology, 35
–93 Marcel Dekker, Inc., New York (2001). Google Scholar
D. Huang,
E. A. Swanson,
C. P. Lin,
J. S. Schuman,
W. G. Stinson,
W. Chang,
M. R. Hee,
T. Flotte,
K. Gregory,
C. A. Puliafito, and
J. G. Fujimoto,
“Optical coherence tomography,”
Science, 254 1178
–1181
(1991). 0036-8075 Google Scholar
Handbook of Optical Coherence Tomography, Marcel Dekker, Inc., New York (2001). Google Scholar
Optical Coherence Tomography of Ocular Diseases, Slack, Inc., Thorofare, NJ (2004). Google Scholar
G. J. Tearney,
M. E. Brezinski,
B. E. Bouma,
S. A. Boppart,
C. Pitris,
J. F. Southern, and
J. G. Fujimoto,
“In vivo endoscopic optical biopsy with optical coherence tomography,”
Science, 276 2037
–2039
(1997). https://doi.org/10.1126/science.276.5321.2037 0036-8075 Google Scholar
M. E. Brezinski,
G. J. Tearney,
B. E. Bouma,
J. A. Izatt,
M. R. Hee,
E. A. Swanson,
J. F. Southern, and
J. G. Fujimoto,
“Optical coherence tomography for optical biopsy: properties and demonstration of vascular pathology,”
Circulation, 93 1206
–1213
(1996). 0009-7322 Google Scholar
S. A. Boppart,
B. E. Bouma,
C. Pitris,
G. J. Tearney,
J. F. Southern,
M. E. Brezinski, and
J. G. Fujimoto,
“Intraoperative assessment of microsurgery with three-dimensional optical coherence tomography,”
Radiology, 208 81
–86
(1998). 0033-8419 Google Scholar
Y. T. Pan,
T. Q. Xie,
C. W. Du,
S. Bastacky,
S. Meyers, and
M. L. Zeidel,
“Enhancing early bladder cancer detection with fluorescence-guided endoscopic optical coherence tomography,”
Opt. Lett., 28 2485
–2487
(2003). 0146-9592 Google Scholar
I. K. Jang,
G. J. Tearney,
B. MacNeill,
M. Takano,
F. Moselewski,
N. Ifitma,
M. Shishkov,
S. Houser,
H. T. Aretz,
E. F. Halpern, and
B. E. Bouma,
“In vivo characterization of coronary atherosclerosic plaque by use of optical coherence tomography,”
Circulation, 111 1551
–1555
(2005). 0009-7322 Google Scholar
K. Bizheva,
A. Unterhuber,
B. Hermann,
B. Povazay,
H. Sattmann,
A. F. Fercher,
W. Drexler,
M. Preusser,
H. Budka,
A. Stingl, and
T. Le,
“Imaging ex vivo healthy and pathologic human brain tissue with ultra-high-resolution optical coherence tomography,”
J. Biomed. Opt., 10
(1), 011006-1
–7
(2005). https://doi.org/10.1117/1.1851513 1083-3668 Google Scholar
X. J. Wang,
T. E. Milner, and
J. S. Nelson,
“Characterization of fluid flow velocity by optical Doppler tomography,”
Opt. Lett., 20 1337
–1339
(1995). 0146-9592 Google Scholar
Z. Chen,
T. E. Milner,
S. Srinivas, and
X. Wang,
“Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography,”
Opt. Lett., 22 1119
–1121
(1997). https://doi.org/10.1023/A:1027365202328 0146-9592 Google Scholar
S. Yazdanfar,
M. D. Kulkarni, and
J. A. Izatt,
“High resolution imaging of in vivo cardiac dynamics using color Doppler optical coherence tomography,”
Opt. Express, 1 424
–431
(1997). 1094-4087 Google Scholar
J. K. Barton,
J. A. Izatt,
M. D. Kulkarni,
S. Yazdanfar, and
A. J. Welch,
“Three-dimensional reconstruction of blood vessels from in vivo color Doppler optical coherence tomography images,”
Dermatology (Basel, Switz.), 198 355
–361
(1999). https://doi.org/10.1159/000018148 1018-8665 Google Scholar
A. M. Rollins,
S. Yazdanfar,
J. K. Barton, and
J. A. Izatt,
“Real-time in vivo color Doppler optical coherence tomography,”
J. Biomed. Opt., 7 123
–129
(2002). https://doi.org/10.1117/1.1428291 1083-3668 Google Scholar
J. F. de Boer,
T. E. Milner,
M. J. C. van Gemert, and
J. S. Nelson,
“Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography,”
Opt. Lett., 22 934
–936
(1997). 0146-9592 Google Scholar
M. J. Everett,
K. Schoenenberger,
B. W. Colston Jr., and
L. B. Da Silva,
“Birefringence characterization of biological tissue by use of optical coherence tomography,”
Opt. Lett., 23 228
–230
(1998). 0146-9592 Google Scholar
S. Jiao and
L. V. Wang,
“Two-dimensional depth-resolved Mueller matrix of biological tissue measured with double-beam polarization-sensitive optical coherence tomography,”
Opt. Lett., 27 101
–103
(2002). 0146-9592 Google Scholar
J. F. de Boer and
T. E. Milner,
“Review of polarization sensitive optical coherence tomography and Stokes vector determination,”
J. Biomed. Opt., 7
(3), 359
–371
(2002). https://doi.org/10.1117/1.1483879 1083-3668 Google Scholar
R. Uma Maheswari,
H. Takaoka,
R. Homma,
H. Kadono, and
M. Tanifuji,
“Implementation of optical coherence tomography (OCT) in visualization of functional structures of cat visual cortex,”
Opt. Commun., 202 47
–54
(2002). https://doi.org/10.1016/S0030-4018(02)01079-9 0030-4018 Google Scholar
M. Lazebnik,
D. L. Marks,
K. Potgieter,
R. Gillette, and
S. A. Boppart,
“Functional optical coherence tomography for detecting neural activity through scattering changes,”
Opt. Lett., 28 1218
–1220
(2003). 0146-9592 Google Scholar
K. Bizheva,
R. Pflug,
B. Hermann,
B. Povay,
S. Gasparoni,
H. Sattmann,
A. Unterhuber,
E. M. Anger,
H. Reitsamer,
S. Popov,
J. R. Tylor,
V. P. Gapontsev,
P. Ahnelt, and
W. Drexler,
“Noninvasive spatially resolved probing of retinal physiology with functional ultrahigh resolution optical coherence tomography,”
(2005). Google Scholar
C. Yang,
“Molecular contrast optical coherence tomography: a review,”
Photochem. Photobiol., 81 215
–237
(2005). 0031-8655 Google Scholar
M. Horisberger,
“Colloidal gold: a cytochemical marker for light and fluorescent microscopy and for transmission and scanning electron microscopy,”
Scan Electron Microsc., 11 9
–31
(1981). https://doi.org/10.1007/BF01148949 0586-5581 Google Scholar
C. Christiansen,
H. Kryvi,
P. C. Sontum, and
T. Skotland,
“Physical and biochemical characterization of Albunex, a new ultrasound contrast agent consisting of air-filled albumin microspheres suspended in a solution of human albumin,”
Biotechnol. Appl. Biochem., 19 307
–320
(1994). 0885-4513 Google Scholar
J. K. Barton,
J. B. Hoying, and
C. J. Sullivan,
“Use of microbubbles as an optical coherence tomography contrast agent,”
Acad. Radiol., 9S 52
–55
(2002). 1076-6332 Google Scholar
T. M. Lee,
A. L. Oldenburg,
S. Sitafalwalla,
D. L. Marks,
W. Luo,
F. Jean-Jacques Toublan,
K. S. Suslick, and
S. A. Boppart,
“Engineered microsphere contrast agents for optical coherence tomography,”
Opt. Lett., 28 1546
–1548
(2003). 0146-9592 Google Scholar
J. R. Gunther,
A. L. Oldenburg, and
S. A. Boppart,
“Macrophage viability following exposure and imaging of optical coherence tomography protein microsphere contrast agents,”
(2005) Google Scholar
A. L. Klibanov,
“Targeted delivery of gas-filled microspheres, contrast agents for ultrasound imaging,”
Adv. Drug Delivery Rev., 37 139
–157
(1999). https://doi.org/10.1016/S0169-409X(98)00104-5 0169-409X Google Scholar
K. Sokolov,
M. Follen,
J. Aaron,
I. Pavlova,
A. Malpica,
R. Lotan, and
R. Richards-Kortum,
“Real-time vital optical imaging of precancer using anti-epidermal growth factor receptor antibodies conjugated to gold nanoparticles,”
Cancer Res., 63 1999
–2004
(2003). 0008-5472 Google Scholar
K. Sokolov,
J. Aaron,
B. Hsu,
D. Nida,
A. Gillenwater,
M. Follen,
C. MacAulay,
K. Adler-Storthz,
B. Korgel,
M. Descour,
R. Pasqualini,
W. Arap,
W. Lam, and
R. Richards-Kortum,
“Optical systems for in vivo molecular imaging of cancer,”
Technol. Cancer Res. Treat., 2 491
–504
(2003). 1533-0346 Google Scholar
J. N. Anker and
R. Kopelman,
“Magnetically modulated optical nanoprobes,”
Appl. Phys. Lett., 82 1102
–1104
(2003). https://doi.org/10.1063/1.1544435 0003-6951 Google Scholar
Scientific and Clinical Applications of Magnetic Carriers, Plenum Press, New York (1997). Google Scholar
A. L. Oldenburg,
J. R. Gunther,
F. Jean-Jacques Toublan,
D. L. Marks,
K. S. Suslick, and
S. A. Boppart,
“Magnetic contrast agents for optical coherence tomography,”
Proc. SPIE, 5316 91
–98
(2004). 0277-786X Google Scholar
A. L. Oldenburg,
J. R. Gunther,
F. Jean-Jacques Toublan,
D. L. Marks,
K. S. Suslick, and
S. A. Boppart,
“Selective OCT imaging of cells using magnetically-modulated optical contrast agents,”
405
–406
(2003). Google Scholar
A. L. Oldenburg,
J. R. Gunther, and
S. A. Boppart,
“Imaging magnetically labeled cells with magnetomotive optical coherence tomography,”
Opt. Lett., 30 747
–749
(2005). https://doi.org/10.1364/OL.30.000747 0146-9592 Google Scholar
S. Hamaguchi,
I. Tohnai,
A. Ito,
K. Mitsudo,
T. Shigetomi,
M. Ito,
H. Honda,
T. Kobayashi, and
M. Ueda,
“Selective hyperthermia using magnetoliposomes to target cervical lymph node metastasis in a rabbit tongue tumor model,”
Cancer Sci., 94 834
–839
(2003). Google Scholar
E. Romanus,
M. Huckel,
C. Gross,
S. Prass,
W. Weitschies,
R. Brauer, and
P. Weber,
“Magnetic nanoparticle relaxation measurement as a novel tool for in vivo diagnostics,”
J. Magn. Magn. Mater., 252 387
–389
(2002). https://doi.org/10.1016/S0304-8853(02)00645-5 0304-8853 Google Scholar
A. S. Lubbe,
C. Alexiou, and
C. Bergemann,
“Clinical applications of magnetic drug targeting,”
J. Surg. Res., 95 200
–206
(2001). 0022-4804 Google Scholar
A. H. Schmieder,
P. M. Winter,
S. D. Caruthers,
T. D. Harris,
T. A. Williams,
J. S. Allen,
E. K. Lacy,
H. Zhang,
M. J. Scott,
G. Hu,
J. D. Robertson,
S. A. Wickline, and
G. M. Lanza,
“Molecular MR imaging of melanoma angiogenesis with -targeted paramagnetic nanoparticles,”
Magn. Reson. Med., 53 621
–627
(2005). https://doi.org/10.1002/mrm.20391 0740-3194 Google Scholar
D. J. Faber,
E. G. Mik,
M. C. G. Aalders, and
T. G. van Leeuwen,
“Light absorption of (oxy-)hemoglobin assessed by spectroscopic optical coherence tomography,”
Opt. Lett., 28 1436
–1438
(2003). 0146-9592 Google Scholar
T. Stren,
A. Simonsen,
O. J. Lkberg,
T. Lindmo,
L. O. Svaasand, and
A. Ryset,
“Measurement of dye diffusion in agar by use of low-coherence interferometry,”
Opt. Lett., 28 1215
–1217
(2003). 0146-9592 Google Scholar
C. Yang,
L. E. McGuckin,
J. D. Simon,
M. A. Choma,
B. E. Applegate, and
J. A. Izatt,
“Spectral triangulation molecular contrast optical coherence tomography with indocyanine green as the contrast agent,”
Opt. Lett., 29 2016
–2018
(2004). https://doi.org/10.1364/OL.29.002016 0146-9592 Google Scholar
C. Xu,
J. Ye,
D. L. Marks, and
S. A. Boppart,
“Near-infrared dyes as contrast-enhancing agents for spectroscopic optical coherence tomography,”
Opt. Lett., 29 1647
–1649
(2004). https://doi.org/10.1364/OL.29.001647 0146-9592 Google Scholar
K. D. Rao,
M. A. Choma,
S. Yazdanfar,
A. M. Rollins, and
J. A. Izatt,
“Molecular contrast in optical coherence tomography by use of a pump-probe technique,”
Opt. Lett., 28 340
–342
(2003). https://doi.org/10.1038/425340a 0146-9592 Google Scholar
C. Yang,
M. A. Choma,
L. E. Lamb,
J. D. Simon, and
J. A. Izatt,
“Protein-based molecular contrast optical coherence tomography with phytochrome as the contrast agent,”
Opt. Lett., 29 1396
–1398
(2004). https://doi.org/10.1364/OL.29.001396 0146-9592 Google Scholar
A. Wei,
“Plasmonic nanomaterials,”
Nanoparticles: Scaffolds and Building Blocks, 173
–200 Kluwer Academic, New York (2003). Google Scholar
J. Yguerabide and
E. E. Yguerabide,
“Light-scattering submicroscopic particles as highly fluorescent analogs and their use as tracer labels in clinical and biological applications: I. Theory,”
Anal. Biochem., 262 137
–156
(1998). https://doi.org/10.1006/abio.1998.2759 0003-2697 Google Scholar
C. Loo,
A. Lin,
L. Hirsch,
M. H. Lee,
J. Barton,
N. Halas,
J. West, and
R. Drezek,
“Nanoshell-enabled photonics-based imaging and therapy of cancer,”
Technol. Cancer Res. Treat., 3 33
–40
(2004). 1533-0346 Google Scholar
A. L. Oldenburg,
D. A. Zweifel,
C. Xu,
A. Wei, and
S. A. Boppart,
“Characterization of plasmon-resonant gold nanorods as near-infrared optical contrast agents investigated using a double-integrating sphere system,”
Proc. SPIE, 5703 50
–60
(2005). 0277-786X Google Scholar
J. Chen,
F. Saeki,
B. J. Wiley,
H. Cang,
M. J. Cobb,
Z. Y. Li,
L. Au,
H. Zhang,
M. B. Kimmey,
X. Li, and
Y. Xia,
“Gold nanocages: bioconjugation and their potential use as optical imaging contrast agents,”
Nano Lett., 5 473
–477
(2005). https://doi.org/10.1021/nl047950t 1530-6984 Google Scholar
K. Chen,
Y. Liu,
G. Ameer, and
V. Backman,
“Optimal design of structured nanospheres for ultrasharp light-scattering resonances as molecular imaging multilabels,”
J. Biomed. Opt., 10 024005
(2005). https://doi.org/10.1117/1.1899684 1083-3668 Google Scholar
S. L. Westcott,
J. B. Jackson,
C. Radloff, and
N. J. Halas,
“Relative contributions to the plasmon line shape of metal nanoshells,”
Phys. Rev. B, 66 155431-1
–5
(2002). https://doi.org/10.1103/PhysRevB.66.155431 0163-1829 Google Scholar
T. S. Tkaczyk,
M. Rahman,
V. Mack,
K. Sokolov,
J. D. Rogers,
R. Richards-Kortum, and
M. R. Descour,
“High resolution, molecular-specific, reflectance imaging in optically dense tissue phantoms with structure-illumination,”
Opt. Express, 12 3745
–3758
(2004). https://doi.org/10.1364/OPEX.12.003745 1094-4087 Google Scholar
J. B. Jackson,
S. L. Westcoot,
L. R. Hirsch,
J. L. West, and
N. J. Halas,
“Controlling the surface enhanced Raman effect via the nanoshell geometry,”
Appl. Phys. Lett., 82 257
–259
(2003). https://doi.org/10.1063/1.1534916 0003-6951 Google Scholar
R. D. Averitt,
S. L. Westcoot, and
N. J. Halas,
“Linear optical properties of gold nanoshells,”
J. Opt. Soc. Am. B, 16 1824
–1832
(1999). 0740-3224 Google Scholar
L. R. Hirsch,
R. J. Stafford,
J. A. Bankson,
S. R. Sershen,
B. Rivera,
R. E. Price,
J. D. Hazle,
N. J. Halas, and
J. L. West,
“Nanoshell-mediated near-infrared thermal therapy of tumors under magnetic resonance guidance,”
Proc. Natl. Acad. Sci. U.S.A., 100 13549
–13554
(2003). https://doi.org/10.1073/pnas.2232479100 0027-8424 Google Scholar
S. Link,
M. B. Mohamed, and
M. A. El-Sayed,
“Simulation of the optical absorption spectra of gold nanorods as a function of their aspect ratio and the effect of the medium dielectric constant,”
J. Phys. Chem. B, 103 3073
–3077
(1999). https://doi.org/10.1021/jp990183f 1089-5647 Google Scholar
C. Sonnichsen,
T. Franzl,
T. Wilk,
G. von Plessen, and
J. Feldmann,
“Drastic reduction of plasmon damping in gold nanorods,”
Phys. Rev. Lett., 88 077402-1
–3
(2002). https://doi.org/10.1103/PhysRevLett.88.077402 0031-9007 Google Scholar
U. Morgner,
W. Drexler,
F. C. Kartner,
X. D. Li,
C. Pitris,
E. P. Ippen, and
J. G. Fujimoto,
“Spectroscopic optical coherence tomography,”
Opt. Lett., 25 111
–113
(2000). 0146-9592 Google Scholar
R. Leitgeb,
M. Wojtkowski,
A. Kowalczyk,
C. K. Hitzenberger,
M. Sticker, and
A. F. Fercher,
“Spectral measurement of absorption by spectroscopic frequency-domain optical coherence tomography,”
Opt. Lett., 25 820
–822
(2000). 0146-9592 Google Scholar
B. Hermann,
K. Bizheva,
A. Unterhuber,
B. Povazay,
H. Sattmann,
L. Schmetterer,
A. F. Fercher, and
W. Drexler,
“Precision of extracting absorption profiles from weakly scattering media with spectroscopic time-domain optical coherence tomography,”
Opt. Express, 12 1677
–1688
(2004). https://doi.org/10.1364/OPEX.12.001677 1094-4087 Google Scholar
C. Xu,
F. Kamalabadi, and
S. A. Boppart,
“Comparative performance analysis of time-frequency distributions for spectroscopic optical coherence tomography,”
Appl. Opt., 44 1813
–1822
(2005). https://doi.org/10.1364/AO.44.001813 0003-6935 Google Scholar
Practical Time-Frequency Analysis, Academic Press, San Diego, CA (1998). Google Scholar
L. Cohen,
“Time-frequency distributions—a review,”
Proc. IEEE, 77 941
–981
(1989). https://doi.org/10.1109/5.30749 0018-9219 Google Scholar
C. Xu,
D. L. Marks,
M. N. Do, and
S. A. Boppart,
“Separation of absorption and scattering profiles in spectroscopic optical coherence tomography using a least-squares algorithm,”
Opt. Express, 12 4790
–4803
(2004). https://doi.org/10.1364/OPEX.12.004790 1094-4087 Google Scholar
H. Bruhn,
P. Fransson, and
J. Frahm,
“Modulation of cerebral blood oxygenation by indomethacin: MRI at rest and functional brain activation,”
J. Magn. Reson Imaging, 13 325
–334
(2001). 1053-1807 Google Scholar
B. Chance,
“Near-infrared images using continuous, phase-modulated, and pulsed light with quantitation of blood and blood oxygenation,”
Ann. N.Y. Acad. Sci., 838 29
–45
(1998). 0077-8923 Google Scholar
Y. Jiang,
I. Tomov,
Y. Wang, and
Z. Chen,
“Second-harmonic optical coherence tomography,”
Opt. Lett., 29 1090
–1092
(2004). https://doi.org/10.1364/OL.29.001090 0146-9592 Google Scholar
C. Vinegoni,
J. S. Bredfeldt,
D. L. Marks, and
S. A. Boppart,
“Nonlinear optical contrast enhancement for optical coherence tomography,”
Opt. Express, 12 331
–341
(2004). https://doi.org/10.1364/OPEX.12.000331 1094-4087 Google Scholar
Y. Jiang,
I. Tomov,
Y. Wang, and
Z. Chen,
“High resolution second harmonic optical coherence tomography,”
Opt. Photonics News, 15 22
(2004). https://doi.org/10.1364/OPN.15.11.000022 1047-6938 Google Scholar
B. E. Applegate,
C. Yang,
A. M. Rollins, and
J. A. Izatt,
“Polarization-resolved second-harmonic-generation optical coherence tomography in collagen,”
Opt. Lett., 29 2252
–2254
(2004). https://doi.org/10.1364/OL.29.002252 0146-9592 Google Scholar
S. Yazdanfar,
L. H. Laiho, and
P. T. C. So,
“Interferometric second harmonic generation microscopy,”
Opt. Express, 12 2739
–2745
(2004). https://doi.org/10.1364/OPEX.12.002739 1094-4087 Google Scholar
M. D. Duncan,
J. Reintjes, and
T. J. Mannucia,
“Scanning coherent anti-Stokes Raman microscope,”
Opt. Lett., 7 350
–352
(1982). 0146-9592 Google Scholar
A. Zumbusch,
G. R. Holtom, and
X. S. Xie,
“Three-dimensional vibrational imaging by coherent anti-Stokes Raman scattering,”
Phys. Rev. Lett., 82 4142
–4145
(1999). https://doi.org/10.1103/PhysRevLett.82.4142 0031-9007 Google Scholar
E. O. Potma,
D. J. Jones,
J. X. Cheng,
X. S. Xie, and
J. Ye,
“High sensitivity coherent anti-Stokes Raman scattering microscopy with two tightly synchronized picosecond lasers,”
Opt. Lett., 27 1168
–1170
(2002). 0146-9592 Google Scholar
J.-X. Cheng,
A. Volkmer,
L. D. Book, and
X. S. Xie,
“An epi-detected anti-Stokes Raman scattering (E-CARS) microscope with high spectral resolution and high sensitivity,”
J. Phys. Chem. B, 105 1277
–1280
(2001). https://doi.org/10.1021/jp003774a 1089-5647 Google Scholar
J.-X. Cheng,
L. D. Book, and
X. S. Xie,
“Polarization coherent anti-Stokes Raman scattering microscopy,”
Opt. Lett., 26 1341
–1343
(2001). 0146-9592 Google Scholar
N. Dudovich,
D. Oron, and
Y. Silberberg,
“Single-pulse coherent controlled nonlinear Raman spectroscopy and microscopy,”
Nature (London), 418 512
–514
(2002). https://doi.org/10.1038/nature00933 0028-0836 Google Scholar
G. W. H. Wurpel,
J. M. Schins, and
M. Muller,
“Direct measurement of chain order in single phospholipid mono- and bilayers with multiplex CARS,”
J. Phys. Chem. B, 108 3400
–3403
(2004). https://doi.org/10.1021/jp037629j 1089-5647 Google Scholar
K. P. Knutsen,
J. C. Johnson,
A. E. Miller,
P. B. Petersen, and
R. J. Saykally,
“High spectral resolution multiplex CARS microscopy using chirped pulses,”
Chem. Phys. Lett., 387 436
–441
(2004). https://doi.org/10.1016/j.cplett.2004.02.049 0009-2614 Google Scholar
D. L. Marks and
S. A. Boppart,
“Nonlinear interferometric vibrational imaging,”
Phys. Rev. Lett., 92 123905-1
–4
(2004). https://doi.org/10.1103/PhysRevLett.92.123905 0031-9007 Google Scholar
J. S. Bredfeldt,
C. Vinegoni,
D. L. Marks, and
S. A. Boppart,
“Molecularly sensitive optical coherence tomography,”
Opt. Lett., 30 495
–497
(2005). https://doi.org/10.1364/OL.30.000495 0146-9592 Google Scholar
D. L. Marks,
C. Vinegoni,
J. S. Bredfeldt, and
S. A. Boppart,
“Interferometric differentiation between resonant coherent anti-Stokes Raman scattering and nonresonant four-wave-mixing processes,”
Appl. Phys. Lett., 85 5787
–5789
(2004). https://doi.org/10.1063/1.1829162 0003-6951 Google Scholar
C. L. Evans,
E. O. Potma, and
X. S. Xie,
“Coherent anti-Stokes Raman scattering spectral interferometry: determination of the real and imaginary components of nonlinear susceptibility chi(3) for vibrational microscopy,”
Opt. Lett., 29 2923
–2925
(2004). https://doi.org/10.1364/OL.29.002923 0146-9592 Google Scholar
Y. Lu,
E. Sega,
C. P. Leamon, and
P. S. Low,
“Folate receptor-targeted immunotherapy of cancer: mechanism and therapeutic potential,”
Adv. Drug Delivery Rev., 56 1161
–1176
(2004). https://doi.org/10.1016/j.addr.2004.01.009 0169-409X Google Scholar
K. T. Wheeler,
L. M. Wang,
C. A. Wallen,
S. R. Childers,
J. M. Cline,
P. C. Keng, and
R. H. Mach,
“Sigma-2 receptors as a biomarker of proliferation in solid tumours,”
Br. J. Cancer, 82 1223
–1232
(2000). 0007-0920 Google Scholar
C. Xi,
M. Balberg,
S. A. Boppart, and
L. Raskin,
“Use of DNA and peptide nucleic acid (PNA) molecular beacons for the detection and quantification of rRNA in solutions and in whole cells,”
Appl. Environ. Microbiol., 69 5673
–5678
(2003). https://doi.org/10.1128/AEM.69.9.5673-5678.2003 0099-2240 Google Scholar
X. H. Peng,
Z. H. Cao,
J. T. Xia,
G. W. Carlson,
M. M. Lewis,
W. C. Wood, and
L. Yang,
“Real-time detection of gene expression in cancer cells using molecular beacon imaging: new strategies for cancer research,”
Cancer Res., 65 1909
–1917
(2005). 0008-5472 Google Scholar
C. H. Tung,
Q. Zeng,
K. Shah,
D. E. Kim,
D. Schellingerhout, and
R. Weissleder,
“In vivo imaging of beta-galactosidase activity using far red fluorescent switch,”
Cancer Res., 64 1579
–1583
(2004). 0008-5472 Google Scholar
J. Haseloff,
E. L. Dormand, and
A. H. Brand,
“Live imaging with green fluorescent protein,”
Methods Mol. Biol., 122 241
–259
(1999). 1064-3745 Google Scholar
B. E. Applegate,
M. V. Sarunik,
C. Yang, and
J. A. Izatt,
“Molecular contrast optical coherence tomography: SNR comparison of techniques and introduction of ground state recovery pump-probe OCT,”
Proc. SPIE, 5690 182
–186
(2005). 0277-786X Google Scholar
A. Vitkin,
J. Woolsey,
B. C. Wilson, and
R. R. Anderson,
“Optical and thermal characterization of natural (sepia officinalis) melanin,”
Photochem. Photobiol., 59 455
–462
(1994). 0031-8655 Google Scholar
O. Clement,
N. Siauve,
C. A. Cuenod, and
G. Frija,
“Liver imaging with ferumoxides (Feridex): fundamentals, controversies, and practical aspects,”
Top Magn. Reson Imaging, 9 167
–182
(1998). 0899-3459 Google Scholar
S. L. Owens,
“Intravenous and indocyanine green angiography,”
Br. J. Ophthamol., 75 743
–755
(2004). 0007-1161 Google Scholar
|