X-ray polarization measurements can provide unique information that is complementary to that obtained through spectroscopic or imaging observations. However, there have been few cases where significant x-ray polarization has been observed. XL-Calibur, conducted in collaboration between Japan, the United States of America, and Sweden, is a balloon-borne mission that aims to conduct high-sensitivity polarimetric observations in the hard x-ray band from 15 to 80 keV. The Japanese group is in charge of developing the Hard X-ray Telescope (HXT) with high light-gathering power. Optical adjustments were completed in 2020, and the performance of the HXT was measured in June 2021 at the SPring-8 (synchrotron radiation facility in Hyogo, Japan). Subsequently, in July 2022, the first observation was conducted from Sweden to Canada. After the flight, the HXT was recovered, and we measured its performance again. By comparing the HXT performances before and after the flight, we found no significant changes that can affect the second flight scheduled in 2024.
IXPE, the first observatory dedicated to imaging x-ray polarimetry, was launched on Dec 9, 2021 and is operating successfully. A partnership between NASA and the Italian Space Agencey (ASI) IXPE features three x-ray telescopes each comprised of a mirror module assembly with a polarization sensitive detector at its focus. An extending boom was deployed on orbit to provide the necessary 4 m focal length. A three-axis-stabilized spacecraft provides power, attitude determination and control, and commanding. After one year of observation IXPE has measured statistically significant polarization from almost all the classes of celestial sources that emit X-rays. In the following we describe the IXPE mission, reporting on its performance after 1.5 year of operations. We show the main astrophysical results which are outstanding for a SMEX mission.
XL-Calibur is a balloon-borne mission for hard x-ray polarimetry. The first launch is currently scheduled from Sweden in summer 2022. Japanese collaborators provide a hard x-ray telescope to the mission. The telescope’s design is identical to the Hard X-ray Telescope (HXT, conically-approximated Wolter-I optics) on board ASTROH with the same focal length of 12 m and the aperture of 45 cm, which can focus x-rays up to 80 keV. The telescope is divided into three segments in the circumferential direction, and confocal 213 grazing-incidence mirrors are precisely placed in the primary and secondary sections of each segment. The surfaces of the mirrors are coated with Pt/C depth-graded multilayer to reflect hard x-rays efficiently by the Bragg reflection. To achieve the best focus, optical adjustment of all of the segments was performed at the SPring-8/BL20B2 synchrotron radiation facility during 2020. A final performance evaluation was conducted in June 2021 and the experiment yields the effective area of 175 cm2 and 73 cm2 at 30 keV and 50 keV, respectively, with its half-power diameter of the point spread function as 2.1 arcmin. The field of view, defined as the full width of the half-maximum of the vignetting curve, is 5.9 arcmin.
Launched on 2021 December 9, the Imaging X-ray Polarimetry Explorer (IXPE) is a NASA Small Explorer Mission in collaboration with the Italian Space Agency (ASI). The mission will open a new window of investigation—imaging x-ray polarimetry. The observatory features three identical telescopes, each consisting of a mirror module assembly with a polarization-sensitive imaging x-ray detector at the focus. A coilable boom, deployed on orbit, provides the necessary 4-m focal length. The observatory utilizes a three-axis-stabilized spacecraft, which provides services such as power, attitude determination and control, commanding, and telemetry to the ground. During its 2-year baseline mission, IXPE will conduct precise polarimetry for samples of multiple categories of x-ray sources, with follow-on observations of selected targets.
Scheduled to launch in late 2021 the Imaging X-ray Polarimetry Explorer (IXPE) is a Small Explorer Mission designed to open up a new window of investigation -- X-ray polarimetry. The IXPE observatory features 3 identical telescope each consisting of a mirror module assembly with a polarization-sensitive imaging x-ray detector at its focus. An extending beam, deployed on orbit provides the necessary 4 m focal length. The payload sits atop a 3-axis stabilized spacecraft which among other things provides power, attitude determination and control, commanding, and telemetry to the ground. During its 2-year baseline mission, IXPE will conduct precise polarimetry for samples of multiple categories of x-ray sources, with follow-on observations of selected targets. IXPE is a partnership between NASA and the Italian Space Agency (ASI).
This paper introduces a second-generation balloon-borne hard X-ray polarimetry mission, XL-Calibur. X-ray polarimetry promises to give qualitatively new information about high-energy astrophysical sources, such as pulsars and binary black hole systems. The XL-Calibur contains a grazing incidence X-ray telescope with a focal plane detector unit that is sensitive to linear polarization. The telescope is very similar in design to the ASTRO-H HXT telescopes that has the world’s largest effective area above ~10 keV. The detector unit combines a low atomic number Compton scatterer with a CdZnTe detector assembly to measure the polarization making use of the fact that polarized photons Compton scatter preferentially perpendicular to the electric field orientation. It also contains a CdZnTe imager at the bottom. The detector assembly is surrounded by the improved anti-coincidence shielding, giving a better sensitivity. The pointing system with arcsecond accuracy will be achieved.
XL-Calibur is a balloon-borne hard X-ray polarimetry mission, the first flight of which is currently foreseen for 2021. XL-Calibur carries an X-ray telescope consists of consists of 213 Wolter I grazing-incidence mirrors which are nested in a coaxial and cofocal configuration. The optics design is nearly identical to the Hard X-ray Telescope (HXT) on board the ASTRO-H satellite. The telescope was originally fabricated for the Formation Flying Astronomical Survey Telescope (FFAST) project. However, the telescope can be used for XL-Calibur, since the FFAST project was terminated before completion. The mirror surfaces are coated with Pt/C depth-graded multilayers to reflect hard X-rays above 10 keV by Bragg reflection. The effective area of the telescope is larger than 300 cm^2 at 30 keV. The mirrors are supported by alignment bars in the housing, and each of the bars has a series of 213 grooves to hold the mirrors. To obtain the best focus of the optics, the positions of the mirrors have to be adjusted by tuning the positions of the alignment bars. The tuning of the mirror positions is conducted using the X-ray beam at the synchrotron facility SPring-8 BL20B2, and this process is called optical tuning. First the positions of the second reflectors are tuned, and then those of the first reflectors are tuned. We did the first optical tuning in Jan 2020. The second tuning will be planned between April to July, 2020. This paper reports the current status of the hard X-ray telescope for XL-Calibur.
IXPE, the Imaging X-ray Polarimetry Explorer, is a NASA SMEX mission with an important contribution of ASI that will be launched with a Falcon 9 in 2021 and will reopen the window of X-ray polarimetry after more than 40 years. The payload features three identical telescopes each one hosting one light-weight X-ray mirror fabricated by MSFC and one detector unit with its in-orbit calibration system and the Gas Pixel Detector sensitive to imaging X-ray polarization fabricated by INAF/IAPS, INFN and OHB Italy. The focal length after boom deployment from ATK-Orbital is 4 m, while the spacecraft is being fabricated by Ball Aerospace. The sensitivity will be better than 5.5% in 300 ks for a 1E-11 erg/s/cm2 (half mCrab) in the energy band of 2-8 keV allowing for sensitive polarimetry of extended and point-like X-ray sources. The focal plane instrument is completed, calibrated and it is going to be delivered at MSFC. We will present the status of the mission at about one year from the launch.
All-sky surveys are crucial to discover transient objects. In reality, however, it is impossible to achieve high sensitivity, high cadence, wide sky coverage, and broad wavelength range at the same time. This is where observations with small telescopes can come in significant, as small telescopes often can make high cadence monitoring and flexible operations, playing a complementary role to large observatories. We plan to launch a new 6U-size CubeSat X-ray observatory, NinjaSat, in 2022 to conduct a flexible X-ray observation program. The satellite is equipped with two identical non-imaging Gas Multiplier Counters (GMCs) sensitive to X-rays in the 2–50 keV band with a total effective area of 36 cm2 at 6 keV. Coupled with X-ray collimators of a 2.1° field-of-view, NinjaSat is suitable for flexible multi-wavelength coordinated observations of bright (⪆10 mCrab) X-ray sources with particular emphasis on their time variability. An example of our targets is one of the brightest celestial X-ray objects, Scorpius X-1, which hosts a fast-spinning neutron star and is a candidate source for coherent gravitational waves. The quasi-periodic oscillation (QPO) of neutron-star systems is considered to carry important information on the neutron star’s rotational frequency, which is useful for sensitive gravitational-wave searches. Scorpius X-1, being one of the brightest, provides the best opportunity to study the QPO. Combining with coordinated simultaneous monitoring observations with recently-developed fast optical photometry, the mechanism of the mass accretion of the disk can also be studied. We plan to use NinjaSat also for space science education, particularly X-ray astronomy, for students and the general public.
We present the first application of a time projection chamber polarimeter to measure high energy X-ray polarization above 10 keV. The polarimeter is designed based on the PRAXyS soft X-ray polarimeter. The sealed gas is changed to a gas mixture of 60% argon and 40% dimethyl ether at 1 atm to be sensitive to high energy X-rays. The polarimeter performance is verified with linearly polarized, monochromatic X-rays at a synchrotron radiation facility, KEK Photon Factory BL-14A. The measured modulation factors are 42.4 ± 0.6%, 50.4 ± 0.6%, and 55.0 ± 0.6% at 12, 14, and 16 keV, respectively, and the measured polarization angles are consistent with the expected values at all energies.
The source position determination method of the multiplexing lobster-eye optics (MuLE), which is a newly proposed configuration of the Lobster-Eye (LE) optics to reduce the number of focal plane detectors significantly, was developed. In the MuLE configuration, X-rays came from different field-of-views (FoVs) were focused on a single imager. To separate the multiplexed FoVs, the optics was designed so that cross-like responses of LE mirror in different FoVs had different azimuthal rotation angles. In this paper, we show the method to determine the rotation angles and verify the FoV discrimination power by using a ray tracing simulation. The configuration we assumed in the simulation was nine multiplexed FoVs projecting onto a single imager (nine-segment MuLE optics) with a 30 cm focal length and a 9×9 cm2 effective area of each LE segment. One LE segment covers 9.6°× 9.6° FoV and the total FoV of the nine-segment MuLE configuration was 9 times of that. Our method provided 100% correct FoV discrimination at the 5σ detection limit flux (35–70 mCrab) for a transient source with a duration of 100 s except for the edge of the FoV.
The X-Ray Imaging and Spectroscopy Mission (XRISM) is the successor to the 2016 Hitomi mission that ended prematurely. Like Hitomi, the primary science goals are to examine astrophysical problems with precise highresolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. XRISM carries a 6 x 6 pixelized X-ray micro-calorimeter on the focal plane of an X-ray mirror assembly and a co-aligned X-ray CCD camera that covers the same energy band over a large field of view. XRISM utilizes Hitomi heritage, but all designs were reviewed. The attitude and orbit control system were improved in hardware and software. The number of star sensors were increased from two to three to improve coverage and robustness in onboard attitude determination and to obtain a wider field of view sun sensor. The fault detection, isolation, and reconfiguration (FDIR) system was carefully examined and reconfigured. Together with a planned increase of ground support stations, the survivability of the spacecraft is significantly improved.
HiZ-GUNDAM is a future satellite mission which will lead the time-domain astronomy and the multi-messenger astronomy through observations of high-energy transient phenomena. A mission concept of HiZ-GUNDAM was approved by ISAS/JAXA, and it is one of the future satellite candidates of JAXA’s medium-class mission. We are in pre-phase A (before pre-project) and elaborating the mission concept, mission/system requirements for the launch in the late 2020s. The main themes of HiZ-GUNDAM mission are (1) exploration of the early universe with high-redshift gamma-ray bursts, and (2) contribution to the multi-messenger astronomy. HiZ-GUNDAM has two kinds of mission payload. The wide field X-ray monitors consist of Lobster Eye optics array and focal imaging sensor, and monitor ~1 steradian field of view in 0.5 – 4 keV energy range. The near infrared telescope has an aperture size 30 cm in diameter, and simultaneously observes four wavelength bands between 0.5 – 2.5 μm. In this paper, we introduce the mission overview of HiZ-GUNDAM.
The coded aperture imaging technique is a useful method of x-ray imaging in observational astrophysics. However, the presence of imaging noise or so-called artifacts in a decoded image is a drawback of this method. We propose a coded aperture imaging method using multiple different random patterns for significantly reducing the image artifacts. This aperture mask contains multiple different patterns each of which generates a different artifact distribution in its decoded image. By summing all decoded images of the different patterns, the artifact distributions are cancelled out, and we obtain a remarkably accurate image. We demonstrate this concept with imaging experiments of a monochromatic 16-keV hard x-ray beam at the synchrotron photon facility SPring-8, using the combination of a complementary metal-oxide-semiconductor image sensor and an aperture mask that has four different random patterns composed of holes with a diameter of 27 μm and a separation of 39 μm. The entire imaging system is installed in a 25-cm-long compact size and achieves an angular resolution of <30 arc sec (full-width at half-maximum). In addition, we show by Monte Carlo simulation that the artifacts can be reduced more effectively if the number of different patterns increases to 8 or 16.
We propose a concept of multiplexing lobster-eye (MuLE) optics to achieve significant reductions in the number of focal plane imagers in lobster-eye (LE) wide-field x-ray monitors. In the MuLE configuration, an LE mirror is divided into several segments and the x-rays reflected on each of these segments are focused on a single image sensor in a multiplexed configuration. If each LE segment assumes a different rotation angle, the azimuthal rotation angle of a cross-like image reconstructed from a point source by the LE optics identifies the specific segment that focuses the x-rays on the imager. With a focal length of 30 cm and LE segments with areas of 10 × 10 cm2, ∼1 sr of the sky can be covered with 36 LE segments and only four imagers (with total areas of 10 × 10 cm2). A ray tracing simulation was performed to evaluate the nine-segment MuLE configuration. The simulation showed that the flux (0.5 to 2 keV) associated with the 5σ detection limit was ∼2 × 10 − 10 erg cm − 2 s − 1 (10 mCrab) for a transient with a duration of 100 s. The simulation also showed that the direction of the transient for flux in the range of 14 to 17 mCrab at 0.6 keV was determined correctly with a 99.7% confidence limit. We conclude that the MuLE configuration can become an effective on-board device for small satellites for future x-ray wide-field transient monitoring.
The Imaging X-ray Polarimetry Explorer (IXPE) will add polarization to the properties (time, energy, and position) observed in x-ray astronomy. A NASA Astrophysics Small Explorer (SMEX) in partnership with the Italian Space Agency (ASI), IXPE will measure the 2–8-keV polarization of a few dozen sources during the first 2 years following its 2021 launch. The IXPE Observatory includes three identical x-ray telescopes, each comprising a 4-m-focal-length (grazingincidence) mirror module assembly (MMA) and a polarization-sensitive (imaging) detector unit (DU), separated by a deployable optical bench. The Observatory’s Spacecraft provides typical subsystems (mechanical, structural, thermal, power, electrical, telecommunications, etc.), an attitude determination and control subsystem for 3-axis stabilized pointing, and a command and data handling subsystem communicating with the science instrument and the Spacecraft subsystems.
The Imaging X-ray Polarimetry Explorer (IXPE) will expand the information space for study of cosmic sources, by adding polarization to the properties (time, energy, and position) observed in x-ray astronomy. Selected in 2017 January as a NASA Astrophysics Small Explorer (SMEX) mission, IXPE will be launched into an equatorial orbit in 2021. The IXPE observatory includes three identical x-ray telescopes, each comprising a 4-m-focal-length (grazing-incidence) mirror module assembly (MMA) and a polarization-sensitive (imaging) detector unit (DU). The optical bench separating the MMAs from the DUs is a deployable boom with a tip/tilt/rotation stage for DU-to-MMA (gang) alignment, similar to the configuration used for the NuSTAR observatory. The IXPE mission will provide scientifically meaningful measurements of the x-ray polarization of a few dozen sources in the 2-8 keV band, over the first two years of the mission. For several bright, extended x-ray sources (pulsar wind nebulae, supernova remnants, and an active-galaxy jet), IXPE observations will produce polarization maps indicating the magnetic structure of the synchrotron emitting regions. For many bright pulsating x-ray sources (isolated pulsars, accreting x-ray pulsars, and magnetars), IXPE observations will produce phase-resolved profiles of the polarization degree and position angle.
The Resolve instrument onboard the X-ray Astronomy Recovery Mission (XARM) consists of
an array of 6x6 silicon-thermistor microcalorimeters cooled down to 50 mK
and a high-throughput X-ray mirror assembly with a focal length of 5.6 m.
The XARM is a recovery mission of ASTRO-H/Hitomi,
and is developed by international collaboration of Japan, USA, and Europe.
The Soft X-ray Spectrometer (SXS) onboard Hitomi demonstrated high resolution
X-ray spectroscopy of ~ 5 eV FWHM in orbit for most of the microcalorimeter pixels.
The Resolve instrument is planned to mostly be a copy of the Hitomi SXS and
Soft X-ray Telescope designs, though several changes are planned
based on the lessons learned of Hitomi.
The energy resolution budget of the microcalorimeters is updated,
reflecting the Hitomi SXS results.
We report the current status of the Resolve instrument.
The ASTRO-H mission was designed and developed through an international collaboration of JAXA, NASA, ESA, and the CSA. It was successfully launched on February 17, 2016, and then named Hitomi. During the in-orbit verification phase, the on-board observational instruments functioned as expected. The intricate coolant and refrigeration systems for soft X-ray spectrometer (SXS, a quantum micro-calorimeter) and soft X-ray imager (SXI, an X-ray CCD) also functioned as expected. However, on March 26, 2016, operations were prematurely terminated by a series of abnormal events and mishaps triggered by the attitude control system. These errors led to a fatal event: the loss of the solar panels on the Hitomi mission. The X-ray Astronomy Recovery Mission (or, XARM) is proposed to regain the key scientific advances anticipated by the international collaboration behind Hitomi. XARM will recover this science in the shortest time possible by focusing on one of the main science goals of Hitomi,“Resolving astrophysical problems by precise high-resolution X-ray spectroscopy”.1 This decision was reached after evaluating the performance of the instruments aboard Hitomi and the mission’s initial scientific results, and considering the landscape of planned international X-ray astrophysics missions in 2020’s and 2030’s. Hitomi opened the door to high-resolution spectroscopy in the X-ray universe. It revealed a number of discrepancies between new observational results and prior theoretical predictions. Yet, the resolution pioneered by Hitomi is also the key to answering these and other fundamental questions. The high spectral resolution realized by XARM will not offer mere refinements; rather, it will enable qualitative leaps in astrophysics and plasma physics. XARM has therefore been given a broad scientific charge: “Revealing material circulation and energy transfer in cosmic plasmas and elucidating evolution of cosmic structures and objects”. To fulfill this charge, four categories of science objectives that were defined for Hitomi will also be pursued by XARM; these include (1) Structure formation of the Universe and evolution of clusters of galaxies; (2) Circulation history of baryonic matters in the Universe; (3) Transport and circulation of energy in the Universe; (4) New science with unprecedented high resolution X-ray spectroscopy. In order to achieve these scientific objectives, XARM will carry a 6 × 6 pixelized X-ray micro-calorimeter on the focal plane of an X-ray mirror assembly, and an aligned X-ray CCD camera covering the same energy band and a wider field of view. This paper introduces the science objectives, mission concept, and observing plan of XARM.
The Hitomi (ASTRO-H) mission is the sixth Japanese x-ray astronomy satellite developed by a large international collaboration, including Japan, USA, Canada, and Europe. The mission aimed to provide the highest energy resolution ever achieved at E > 2 keV, using a microcalorimeter instrument, and to cover a wide energy range spanning four decades in energy from soft x-rays to gamma rays. After a successful launch on February 17, 2016, the spacecraft lost its function on March 26, 2016, but the commissioning phase for about a month provided valuable information on the onboard instruments and the spacecraft system, including astrophysical results obtained from first light observations. The paper describes the Hitomi (ASTRO-H) mission, its capabilities, the initial operation, and the instruments/spacecraft performances confirmed during the commissioning operations for about a month.
The soft x-ray spectrometer (SXS) was a cryogenic high-resolution x-ray spectrometer onboard the Hitomi (ASTRO-H) satellite that achieved energy resolution of 5 eV at 6 keV, by operating the detector array at 50 mK using an adiabatic demagnetization refrigerator (ADR). The cooling chain from room temperature to the ADR heat sink was composed of two-stage Stirling cryocoolers, a He4 Joule–Thomson cryocooler, and superfluid liquid helium and was installed in a dewar. It was designed to achieve a helium lifetime of more than 3 years with a minimum of 30 L. The satellite was launched on February 17, 2016, and the SXS worked perfectly in orbit, until March 26 when the satellite lost its function. It was demonstrated that the heat load on the helium tank was about 0.7 mW, which would have satisfied the lifetime requirement. This paper describes the design, results of ground performance tests, prelaunch operations, and initial operation and performance in orbit of the flight dewar and the cryocoolers.
We summarize all of the in-orbit operations of the soft x-ray spectrometer (SXS) onboard the ASTRO-H (Hitomi) satellite. The satellite was launched on February 17, 2016, and the communication with the satellite ceased on March 26, 2016. The SXS was still in the commissioning phase, in which the set-ups were progressively changed. This paper is intended to serve as a concise reference of the events in orbit in order to properly interpret the SXS data taken during its short lifetime and as a test case for planning the in-orbit operation for future microcalorimeter missions.
The Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) is one of three Small Explorer (SMEX)
missions selected by NASA for Phase A study, with a launch date in 2020. The PRAXyS Observatory exploits grazing
incidence X-ray mirrors and Time Projection Chamber Polarimeters capable of measuring the linear polarization of
cosmic X-ray sources in the 2-10 keV band. PRAXyS combines well-characterized instruments with spacecraft rotation
to ensure low systematic errors. The PRAXyS payload is developed at the Goddard Space Flight Center with the Johns
Hopkins University Applied Physics Laboratory, University of Iowa, and RIKEN (JAXA) collaborating on the
Polarimeter Assembly. The LEOStar-2 spacecraft bus is developed by Orbital ATK, which also supplies the extendable
optical bench that enables the Observatory to be compatible with a Pegasus class launch vehicle.
A nine month primary mission will provide sensitive observations of multiple black hole and neutron star sources, where
theory predicts polarization is a strong diagnostic, as well as exploratory observations of other high energy sources.
The primary mission data will be released to the community rapidly and a Guest Observer extended mission will be
vigorously proposed.
The Polarimeter for Relativistic Astrophysical X-ray Sources (PRAXyS) is one of three Small Explorer (SMEX)
missions selected by NASA for Phase A study. The PRAXyS observatory carries an X-ray Polarimeter Instrument (XPI)
capable of measuring the linear polarization from a variety of high energy sources, including black holes, neutron stars,
and supernova remnants. The XPI is comprised of two identical mirror-Time Projection Chamber (TPC) polarimeter
telescopes with a system effective area of 124 cm2 at 3 keV, capable of photon limited observations for sources as faint
as 1 mCrab. The XPI is built with well-established technologies. This paper will describe the performance of the XPI
flight mirror with the engineering test unit polarimeter.
KEYWORDS: X-rays, Sensors, Spectroscopy, Space operations, Lithium, Field effect transistors, Satellites, Calibration, Single crystal X-ray diffraction, Magnetic sensors
We present the overall design and performance of the Astro-H (Hitomi) Soft X-Ray Spectrometer (SXS). The instrument uses a 36-pixel array of x-ray microcalorimeters at the focus of a grazing-incidence x-ray mirror Soft X-Ray Telescope (SXT) for high-resolution spectroscopy of celestial x-ray sources. The instrument was designed to achieve an energy resolution better than 7 eV over the 0.3-12 keV energy range and operate for more than 3 years in orbit. The actual energy resolution of the instrument is 4-5 eV as demonstrated during extensive ground testing prior to launch and in orbit. The measured mass flow rate of the liquid helium cryogen and initial fill level at launch predict a lifetime of more than 4 years assuming steady mechanical cooler performance. Cryogen-free operation was successfully demonstrated prior to launch. The successful operation of the SXS in orbit, including the first observations of the velocity structure of the Perseus cluster of galaxies, demonstrates the viability and power of this technology as a tool for astrophysics.
The Hitomi (ASTRO-H) mission is the sixth Japanese X-ray astronomy satellite developed by a large international collaboration, including Japan, USA, Canada, and Europe. The mission aimed to provide the highest energy resolution ever achieved at E > 2 keV, using a microcalorimeter instrument, and to cover a wide energy range spanning four decades in energy from soft X-rays to gamma-rays. After a successful launch on 2016 February 17, the spacecraft lost its function on 2016 March 26, but the commissioning phase for about a month provided valuable information on the on-board instruments and the spacecraft system, including astrophysical results obtained from first light observations. The paper describes the Hitomi (ASTRO-H) mission, its capabilities, the initial operation, and the instruments/spacecraft performances confirmed during the commissioning operations for about a month.
The Soft X-ray Spectrometer (SXS) is a cryogenic high-resolution X-ray spectrometer onboard the ASTRO-H satellite, that achieves energy resolution better than 7 eV at 6 keV, by operating the detector array at 50 mK using an adiabatic demagnetization refrigerator. The cooling chain from room temperature to the ADR heat sink is composed of 2-stage Stirling cryocoolers, a 4He Joule-Thomson cryocooler, and super uid liquid He, and is installed in a dewar. It is designed to achieve a helium lifetime of more than 3 years with a minimum of 30 liters. The satellite was launched on 2016 February 17, and the SXS worked perfectly in orbit, until March 26 when the satellite lost its function. It was demonstrated that the heat load on the He tank was about 0.7 mW, which would have satisfied the lifetime requirement. This paper describes the design, results of ground performance tests, prelaunch operations, and initial operation and performance in orbit of the flight dewar and cryocoolers.
We summarize all the in-orbit operations of the Soft X-ray Spectrometer (SXS) onboard the ASTRO-H (Hit- omi) satellite. The satellite was launched on 2016/02/17 and the communication with the satellite ceased on 2016/03/26. The SXS was still in the commissioning phase, in which the setups were progressively changed. This article is intended to serve as a reference of the events in the orbit to properly interpret the SXS data taken during its short life time, and as a test case for planning the in-orbit operation for future micro-calorimeter missions.
PolariS (Polarimetry Satellite) is a Japanese small satellite mission dedicated to polarimetry of X-ray and γ-ray sources. The primary aim of the mission is to perform hard X-ray (10-80 keV) polarimetry of sources brighter than 10 mCrab. For this purpose, PolariS employs three hard X-ray telescopes and scattering type imaging polarimeters. PolariS will measure the X-ray polarization for tens of sources including extragalactic ones mostly for the first time. The second purpose of the mission is γ-ray polarimetry of transient sources, such as γ-ray bursts (GRBs). Wide field polarimeters based on similar concept as that used in the IKAROS/GAP but with higher sensitivity will be used, and polarization measurement of 10 GRBs per year is expected.
X-ray polarization measurements hold great promise for studying the geometry and emission mechanisms in the strong gravitational and magnetic fields that surround black holes and neutron stars. In spite of this, the observational situation remains very limited; the last instrument dedicated to X-ray polarimetry flew decades ago on OSO-8, and the few recent measurements have been made by instruments optimized for other purposes. However, the technical capabilities to greatly advance the observational situation are in hand. Recent developments in micro-pattern gas detectors allow use of the polarization sensitivity of the photo-electric effect, which is the dominant interaction in the band above 2 keV. We present the scientific and technical requirements for an X-ray polarization observatory consistent with the scope of a NASA Small Explorer (SMEX) mission, along with a representative catalog of what the observational capabilities and expected sensitivities for the first year of operation could be. The mission is based on the technically robust design of the Gravity and Extreme Magnetism SMEX (GEMS) which completed a Phase B study and Preliminary Design Review in 2012. The GEMS mission is enabled by time projection detectors sensitive to the photo-electric effect. Prototype detectors have been designed, and provide engineering and performance data which support the mission design. The detectors are further characterized by low background, modest spectral resolution, and sub-millisecond timing resolution. The mission also incorporates high efficiency grazing incidence X-ray mirrors, design features that reduce systematic errors (identical telescopes at different azimuthal angles with respect to the look axis, and mounted on a rotating spacecraft platform), and a moderate capability to perform Target of Opportunity observations. The mission operates autonomously in a low earth, low inclination orbit with one to ten downlinks per day and one or more uplinks per week. Data and calibration products will be made available through the High Energy Astrophysics Science and Archival Research Center (HEASARC).
The design of the Time-Projection Chamber (TPC) Polarimeter for the Gravity and Extreme Magnetism Small Explorer (GEMS) was demonstrated to Technology Readiness Level 6 (TRL-6)3 and the flight detectors fabricated, assembled and performance tested. A single flight detector was characterized at the Brookhaven National Laboratory Synchrotron Light Source with polarized X-rays at 10 energies from 2.3–8.0 keV at five detector positions. The detector met all of the GEMS performance requirements. Lifetime measurements have shown that the existing flight design has 23 years of lifetime4, opening up the possibility of relaxing material requirements, in particular the consideration of the use of epoxy, to reduce risk elsewhere. We report on design improvements to the GEMS detector to enable a narrower transfer gap that, when operated with a lower transfer field, reduces asymmetries in the detector response. In addition, the new design reduces cost and risk by simplifying the assembly and reducing production time. Finally, we report on the performance of the narrow-gap detector in response to polarized and unpolarized X-rays.
We present the gain properties of the gas electron multiplier (GEM) foil in pure dimethyl ether (DME) at 190 Torr. The GEM is one of the micro pattern gas detectors and it is adopted as a key part of the X-ray polarimeter for the GEMS mission. The X-ray polarimeter is a time projection chamber operating in pure DME gas at 190 Torr. We describe experimental results of (1) the maximum gain the GEM can achieve without any discharges, (2) the linearity of the energy scale for the GEM operation, and (3) the two-dimensional gain variation of the active area. First, our experiment with 6.4 keV X-ray irradiation of the whole GEM area demonstrates that the maximum effective gain is 2 x 104 with the applied voltage of 580 V. Second, the measured energy scale is linear among three energies of 4.5, 6.4, and 8.0 keV. Third, the two-dimensional gain mapping test derives the standard deviation of the gain variability of 7% across the active area.
We report a Monte-Carlo estimation of the in-orbit performance of a cosmic X-ray polarimeter designed to be installed on the focal plane of a small satellite. The simulation uses GEANT for the transport of photons and energetic particles and results from Magboltz for the transport of secondary electrons in the detector gas. We validated the simulation by comparing spectra and modulation curves with actual data taken with radioactive sources and an X-ray generator. We also estimated the in-orbit background induced by cosmic radiation in low Earth orbit.
We present the development status of the Soft X-ray Spectrometer (SXS) onboard the ASTRO-H mission. The SXS provides the capability of high energy-resolution X-ray spectroscopy of a FWHM energy resolution of < 7eV in the energy range of 0.3 – 10 keV. It utilizes an X-ray micorcalorimeter array operated at 50 mK. The SXS microcalorimeter subsystem is being developed in an EM-FM approach. The EM SXS cryostat was developed and fully tested and, although the design was generally confirmed, several anomalies and problems were found. Among them is the interference of the detector with the micro-vibrations from the mechanical coolers, which is the most difficult one to solve. We have pursued three different countermeasures and two of them seem to be effective. So far we have obtained energy resolutions satisfying the requirement with the FM cryostat.
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions developed by the Institute of Space and Astronautical Science (ISAS), with a planned launch in 2015. The ASTRO-H mission is equipped with a suite of sensitive instruments with the highest energy resolution ever achieved at E > 3 keV and a wide energy range spanning four decades in energy from soft X-rays to gamma-rays. The simultaneous broad band pass, coupled with the high spectral resolution of ΔE ≤ 7 eV of the micro-calorimeter, will enable a wide variety of important science themes to be pursued. ASTRO-H is expected to provide breakthrough results in scientific areas as diverse as the large-scale structure of the Universe and its evolution, the behavior of matter in the gravitational strong field regime, the physical conditions in sites of cosmic-ray acceleration, and the distribution of dark matter in galaxy clusters at different redshifts.
Polarimetry is a powerful tool for astrophysical observations that has yet to be exploited in the X-ray band. For satellite-borne and sounding rocket experiments, we have developed a photoelectric gas polarimeter to measure X-ray polarization in the 2–10 keV range utilizing a time projection chamber (TPC) and advanced micro-pattern gas electron multiplier (GEM) techniques. We carried out performance verification of a flight equivalent unit (1/4 model) which was planned to be launched on the NASA Gravity and Extreme Magnetism Small Explorer (GEMS) satellite. The test was performed at Brookhaven National Laboratory, National Synchrotron Light Source (NSLS) facility in April 2013. The polarimeter was irradiated with linearly-polarized monochromatic X-rays between 2.3 and 10.0 keV and scanned with a collimated beam at 5 different detector positions. After a systematic investigation of the detector response, a modulation factor ≥35% above 4 keV was obtained with the expected polarization angle. At energies below 4 keV where the photoelectron track becomes short, diffusion in the region between the GEM and readout strips leaves an asymmetric photoelectron image. A correction method retrieves an expected modulation angle, and the expected modulation factor, ~20% at 2.7 keV. Folding the measured values of modulation through an instrument model gives sensitivity, parameterized by minimum detectable polarization (MDP), nearly identical to that assumed at the preliminary design review (PDR).
Recent progress in wide field of view or all-sky observations such as Swift/BAT hard X-ray monitor and Fermi GeV gamma-ray observatory has opened up a new era of time-domain high energy astro-physics addressing new insight in, e.g., particle acceleration in the universe. MeV coverage with comparable sensitivity, i.e. 1 ~ 10 mCrab is missing and a new MeV all-sky observatory is needed. These new MeV mission tend to be large, power- consuming and hence expensive, and its realization is yet to come. A compact sub-MeV (0.2-2 MeV) all-sky mission is proposed as a path finder for such mission. It is based on a Si/CdTe semiconductor Compton telescope technology employed in the soft gamma-ray detector onboard ASTRO-H, to be launched in to orbit on late 2015. The mission is kept as small as 0:5 X 0:5 X 0:4 m3, 150 kg in weight and 200 W in power in place of the band coverage above a few MeV, in favor of early realization as a sub-payload to other large platforms, such as the international space station.
PolariS (Polarimetry Satellite) is a Japanese small satellite mission dedicated to polarimetry of X-ray and γ-ray sources. The primary aim of the mission is to perform wide band X-ray (4-80 keV) polarimetry of sources brighter than 10 mCrab. For this purpose, Polaris employs three hard X-ray telescopes and two types of focal plane imaging polarimeters. PolariS observations will measure the X-ray polarization for tens of sources including extragalactic ones mostly for the first time. The second purpose of the mission is γ-ray polarimetry of transient sources, such as γ-ray bursts. Wide field polarimeters based on similar concept as that used in the IKAROS/GAP but with higher sensitivity, i.e., polarization measurement of 10 bursts per year, will be employed.
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated
by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the highenergy
universe via a suite of four instruments, covering a very wide energy range, from 0.3 keV to 600 keV.
These instruments include a high-resolution, high-throughput spectrometer sensitive over 0.3–12 keV with
high spectral resolution of ΔE ≦ 7 eV, enabled by a micro-calorimeter array located in the focal plane of
thin-foil X-ray optics; hard X-ray imaging spectrometers covering 5–80 keV, located in the focal plane of
multilayer-coated, focusing hard X-ray mirrors; a wide-field imaging spectrometer sensitive over 0.4–12 keV,
with an X-ray CCD camera in the focal plane of a soft X-ray telescope; and a non-focusing Compton-camera
type soft gamma-ray detector, sensitive in the 40–600 keV band. The simultaneous broad bandpass, coupled
with high spectral resolution, will enable the pursuit of a wide variety of important science themes.
The scientific objective of the X-ray Advanced Concepts Testbed (XACT) is to measure the X-ray polarization
properties of the Crab Nebula, the Crab pulsar, and the accreting binary Her X-1. Polarimetry is a powerful tool for
astrophysical investigation that has yet to be exploited in the X-ray band, where it promises unique insights into neutron
stars, black holes, and other extreme-physics environments. With powerful new enabling technologies, XACT will
demonstrate X-ray polarimetry as a practical and flight-ready astronomical technique. Additional technologies that
XACT will bring to flight readiness will also provide new X-ray optics and calibration capabilities for NASA missions
that pursue space-based X-ray spectroscopy, timing, and photometry.
MeV and sub-MeV energy band from ~200 keV to ~2 MeV contains rich information of high-energy phenomena
in the universe. The CAST (Compton Telescope for Astro and Solar Terrestrial) mission is planned to be launched
at the end of 2010s, and aims at providing all-sky map in this energy-band for the first time. It is made of a
semiconductor Compton telescope utilizing Si as a scatterer and CdTe as an absorber. CAST provides allsky
sub-MeV polarization map for the first time, as well. The Compton telescope technology is based on the
design used in the Soft Gamma-ray Detector (SGD) onboard ASTRO-H, characterized by its tightly stacked
semiconductor layers to obtain high Compton reconstruction efficiency. The CAST mission is currently planned
as a candidate for the small scientific satellite series in ISAS/JAXA, weighting about 500 kg in total. Scalable
detector design enables us to consider other options as well. Scientific outcome of CAST is wide. It will provide
new information from high-energy sources, such as AGN and/or its jets, supernova remnants, magnetors, blackhole
and neutron-star binaries and others. Polarization map will tell us about activities of jets and reflections in
these sources, as well. In addition, CAST will simultaneously observe the Sun, and depending on its attitude,
the Earth.
J. Hill, R. Baker, J. Black, M. Browne, W. Baumgartner, E. Caldwell, J. Cantwell, A. Davies, A. Desai, P. Dickens, N. Dobson, R. Foxwell, A. Francomacaro, D. Gall, K. Gregory, S. Griffiths, A. Hayato, R. Hampshire, T. Hwang, M. Jhabvala , K. Jahoda, P. Kaaret, S. Lehtonen, N. Martin, J. Mohammed, K. Montt de Garcia, A. Morell, D. Nolan, R. Russell, M. Sampson, J. Sanders, K. Simms, M. Singer, J. Swank, T. Tamagawa, A. Weaver, S. Yerushalmi, J. Xu
The Gravity and Extreme Magnetism Small Explorer (GEMS) will realize its scientific objectives through high sensitivity linear X-ray polarization measurements in the 2-10 keV band. The GEMS X-ray polarimeters, based on the photoelectric effect, provide a strong polarization response with high quantum efficiency over a broad band-pass by a novel implementation of the time projection chamber (TPC). This paper will discuss the basic principles of the TPC polarimeter and describe the details of the mechanical and electrical design of the GEMS flight polarimeter. We will present performance measurements from two GEMS engineering test units in response to polarized and unpolarized X-rays and before and after thermal and vibration tests performed to demonstrate that the design is at a technology readiness level 6 (TRL-6).
The joint JAXA/NASA ASTRO-H mission is the sixth in a series of highly successful X-ray missions initiated
by the Institute of Space and Astronautical Science (ISAS). ASTRO-H will investigate the physics of the
high-energy universe by performing high-resolution, high-throughput spectroscopy with moderate angular
resolution. ASTRO-H covers very wide energy range from 0.3 keV to 600 keV. ASTRO-H allows a combination
of wide band X-ray spectroscopy (5-80 keV) provided by multilayer coating, focusing hard X-ray
mirrors and hard X-ray imaging detectors, and high energy-resolution soft X-ray spectroscopy (0.3-12 keV)
provided by thin-foil X-ray optics and a micro-calorimeter array. The mission will also carry an X-ray CCD
camera as a focal plane detector for a soft X-ray telescope (0.4-12 keV) and a non-focusing soft gamma-ray
detector (40-600 keV) . The micro-calorimeter system is developed by an international collaboration led
by ISAS/JAXA and NASA. The simultaneous broad bandpass, coupled with high spectral resolution of
ΔE ~7 eV provided by the micro-calorimeter will enable a wide variety of important science themes to be
pursued.
The Soft X-ray Spectrometer (SXS) is a cryogenic high resolution X-ray spectrometer onboard the X-ray astronomy
satellite ASTRO-H. The detector array is cooled down to 50 mK using a 3-stage adiabatic demagnetization
refrigerator (ADR). The cooling chain from room temperature to the ADR heat-sink is composed of superfluid
liquid He, a 4He Joule-Thomson cryocooler, and 2-stage Stirling cryocoolers. It is designed to keep 30 L of liquid
He for more than 3 years in the nominal case. It is also designed with redundant subsystems throughout from
room temperature to the ADR heat-sink, to alleviate failure of a single cryocooler or loss of liquid He.
The Gravity and Extreme Magnetism Small Explorer (GEMS) is an astrophysical observatory dedicated to X-ray
polarimetry (2-10 keV) and is being developed for launch in 2014. To maximize the polarization sensitivity of the
observatory, GEMS uses polarimeters based on the photoelectric effect with a gas micropattern time projection chamber
(TPC). We describe the TPC polarimeter concept and the details of the GEMS implementation, including factors that
affect the ultimate polarization sensitivity, including quantum efficiency, modulation factor, systematic errors, and
background.
We present the science and an overview of the Soft X-ray Spectrometer onboard the ASTRO-H mission with
emphasis on the detector system. The SXS consists of X-ray focusing mirrors and a microcalorimeter array and
is developed by international collaboration lead by JAXA and NASA with European participation. The detector
is a 6×6 format microcalorimeter array operated at a cryogenic temperature of 50 mK and covers a 3' ×3' field
of view of the X-ray telescope of 5.6 m focal length. We expect an energy resolution better than 7 eV (FWHM,
requirement) with a goal of 4 eV. The effective area of the instrument will be 225 cm2 at 7 keV; by a factor of
about two larger than that of the X-ray microcalorimeter on board Suzaku. One of the main scientific objectives
of the SXS is to investigate turbulent and/or macroscopic motions of hot gas in clusters of galaxies.
The Soft X-ray Spectrometer (SXS) onboard the NeXT (New exploration X-ray Telescope) is an X-ray spectrometer
utilizing an X-ray microcalorimeter array. Combined with the soft X-ray telescope of 6 m focal length,
the instrument will have a ~ 290cm2 effective at 6.7 keV. With the large effective area and the energy resolution
as good as 6 eV (FWHM), the instrument is very suited for the high-resolution spectroscopy of iron K emission
line. One of the major scientific objectives of SXS is to determine turbulent and/or macroscopic motions of the
hot gas in clusters of galaxies of up to z ~ 1. The instruments will use 6 × 6 or 8 × 8 format microcalorimeter
array which is similar to that of Suzaku XRS. The detector will be cooled to a cryogenic temperature of 50 mK
by multi-stage cooling system consisting of adiabatic demagnetization refrigerator, super fluid He, a 3He Joule
Thomson cooler, and double-stage stirling cycle cooler.
We have developed the gas electron multiplier (GEM) for applying to a cosmic X-ray polarimeter. For a space
use of the GEM, we performed experiments of charged particles irradiation to the GEM as space environmental
tests of cosmic rays. The GEM is irradiated with full-striped iron ions with energy of 500 MeV/n, as a result,
we found that even if a particle deposits an energy of ~ 2 MeV in the detector, it has no direct effect on the
GEM as long as the particle does not hit the GEM directly. In contrast, every time a particle collides with the
GEM, it discharges with a probability of 0.4-40% which depending on the count rate, the applied voltage, and
energy losses, but the mass of particles does not matter. The predicted count rate of discharges in the space
is low enough, so it is negligible compared with a target object. We also found that an irradiation of charged
particles for a certain period causes a destruction of the GEM, but the direct reason remains unclear.
The SXS (Soft X-ray Spectrometer) onboard the coming Japanese X-ray satellite NeXT (New Exploration Xray
Telescope) and the SXC (Spectrum-RG X-ray Calorimeter) in Spectrum-RG mission are microcalorimeter
array spectrometers which will achieve high spectral resolution of ~ 6 eV in 0.3-10.0 keV energy band. These
spectrometers are well-suited to address key problems in high-energy astrophysics. To achieve these high spectral
sensitivities, these detectors require to be operated under 50 mK by using very efficient cooling systems including
adiabatic demagnetization refrigerator (ADR). For both missions, we propose a two-stage series ADR as a cooling
system below 1 K, in which two units of ADR consists of magnetic cooling material, a superconducting magnet,
and a heat switch are operated step by step. Three designs of the ADR are proposed for SXS/SXC. In all three
designs, ADR can attain the required hold time of 23 hours at 50 mK and cooling power of 0.4μW with a low
magnetic fields (1.5/1.5 Tesla or 2.0/3.0 Tesla) in a small configuration (180 mmφ× 319 mm in length).
We also fabricated a new portable refrigerator for a technology investigation of two-stage ADR. Two units of
ADR have been installed at the bottom of liquid He tank. By using this dewar, important technologies such as an operation of two-stage cooling cycle, tight temperature control less than 1 μK (in rms) stability, a magnetic
shielding, saltpills, and gas-gap heat switches are evaluated.
Fine-pitch and thick-foil GEMs have been produced using a laser etching technique for photoelectric X-ray
polarimeters onboard future missions. The finest hole pitch of the thick-foil GEM is 80 μm with a hole diameter
of 40 μm, and a thickness of the insulator is 100 µm. The maximum effective gain in a 70%-30% mixture of argon
and carbon dioxide reaches 3×104 at voltage of 750 V between GEM electrodes. No significant gain increase or
decrease was observed during 24 hours test in which applied high voltage was ramped up and down frequently.
The measured gain stability was less than 4%. An accelerated test of the high voltage ramp up and down for
two years LEO operations were carried out. During the 6500 times voltage ramp up and down, the GEM kept
its gain within 4% variation and no unexpected behavior was observed.
The Hard X-ray Imager (HXI) is one of three focal plane detectors on board the NeXT (New exploration X-ray
Telescope) mission, which is scheduled to be launched in 2013. By use of the hybrid structure composed of
double-sided silicon strip detectors and a cadmium telluride strip detector, it fully covers the energy range of
photons collected with the hard X-ray telescope up to 80 keV with a high quantum efficiency. High spatial
resolutions of 400 micron pitch and energy resolutions of 1-2 keV (FWMH) are at the same time achieved with
low noise front-end ASICs. In addition, thick BGO active shields compactly surrounding the main detection
part, as a heritage of the successful performance of the Hard X-ray Detector (HXD) on board Suzaku satellite,
enable to achive an extremely high background reduction for the cosmic-ray particle background and in-orbit
activation. The current status of hardware development including the design requirement, expected performance,
and technical readinesses of key technologies are summarized.
The hard X-ray imager (HXI) is the primary detector of the NeXT mission, proposed to explore high-energy
non-thermal phenomena in the universe. Combined with a novel hard X-ray mirror optics, the HXI is designed to
provide better than arc-minutes imaging capability with 1 keV level spectroscopy, and more than 30 times higher
sensitivity compared with any existing hard X-ray instruments. The base-line design of the HXI is improving to
secure high sensitivity. The key is to reduce the detector background as far as possible. Based on the experience
of the Suzaku satellite launched in July 2005, the current design has a well-type tight active shield and multi
layered, multi material imaging detector made of Si and CdTe. Technology has been under development for a
few years so that we have reached the level where a basic detector performance is satisfied. Design tuning to
further improve the sensitivity and reliability is on-going.
The hard X-ray detector (HXD) onboard Suzaku covers an energy range of 8-700 keV, and thus in combination with the CCD camera (XIS) gives us an opportunity of wide-band X-ray observations of celestial sources with a good sensitivity over the 0.3-700 keV range. All of 64 Si-PIN photo diodes, 16 GSO/BGO phoswich scintillators, and 20 anti-coincidence BGO scintillators in the HXD are working well since the Suzaku launch on July 2005. The rejection of background events is confirmed to be as effective as expected, and accordingly the HXD achieved the lowest background level of the previously or currently operational missions sensitive in the comparable energy range. The energy and angular responses and timing have been continuously calibrated by the data from the Crab nebula, X-ray pulsars, and other sources, and at present several % accuracy is obtained. Even though the HXD does not perform simultaneous background observations, it detected weak sources with a flux as low as ~0.5 mCrab; stars, X-ray binaries, supernova remnants, active galactic nuclei, and galaxy clusters. Extensive studies of background subtraction enables us to study weaker sources.
The X-ray astronomical satellite Suzaku was successfully launched in July 2005. The onboard Wideband All-sky Monitor (WAM) is designed as the second function of the large, thick BGO anti-coincidence shields of the Hard X-ray Detectors (HXD). It views about half of the whole sky and has a geometrical area of 800 cm2 per side, with a large effective area of 400 cm2 even at 1 MeV. Hence, the WAM is expected to provide unique opportunities to detect high energy emission from GRBs and solar flares in the MeV range. In fact, the WAM has detected at least 47 GRBs, although the fine-tuning of the GRB functions is still in progress. The most impressive GRB result is the bright, hard spectrum GRB 051008, which was detected up to 1 MeV with the WAM. We will present here the in-flight performance of the HXD/WAM during the initial eight-months of operations. The in-flight energy response, spectral and timing capabilities, and in-orbit background are described in this paper.
We present a performance study of a cosmic X-ray polarimeter which is
based on the photoelectric effect in gas, and sensitive to a few to 30
keV range. In our polarimeter, the key device would be the 50 μm
pitch Gas Electron Multiplier (GEM). We have evaluated the modulation
factor using highly polarized X-ray, provided by a synchrotron
accelerator. In the analysis, we selected events by the eccentricity of the charge cloud of the photoelectron track. As a result, we obtained the relationship between the selection criteria for the eccentricity and the modulation factors; for example, when we selected the events which
have their eccentricity of > 0.95, the polarimeter exhibited with
the modulation factor of 0.32. In addition, we estimated the Minimum
Detectable Polarization degree (MDP) of Crab Nebula with our
polarimeter and found 10 ksec observation is enough to detect the
polarization, if we adopt suitable X-ray mirrors.
We have produced various gas electron multiplier foils (GEMs) by using laser etching technique for cosmic X-ray polarimeters. The finest structure GEM we have fabricated has 30 μm-diameter holes on a 50 μm-pitch. The effective gain of the GEM reaches around 5000 at the voltage of 570 V between electrodes. The gain is slightly higher than that of the CERN standard GEM with 70 μm-diameter holes on a 140 μm-pitch. We have fabricated GEMs with thickness of 100 μm which has two times thicker than the standard GEM. The effective gain of the thick-foil GEM is 104 at the applied voltage of 350 V per 50 μm of thickness. The gain is about two orders higher than that of the standard GEM. The remarkable characteristic of the thick-foil GEM is that the effective gain at the beginning of micro-discharge is quite improved. For fabricating the thick-foil GEMs, we have employed new material, liquid crystal polymer (LCP) which has little moisture absorption rate, as an insulator layer instead of polyimide. One of the thick-foil GEM we have fabricated has 8 μm copper layer in the middle of the 100 μm-thick insulator layer. The metal layer in the middle of the foil works as a field-shaper in the multiplication channels, though it slightly decreases the effective gain.
The NeXT mission has been proposed to study high-energy non-thermal phenomena in the universe. The high-energy response of the super mirror will enable us to perform the first sensitive imaging observations up to 80 keV. The focal plane detector, which combines a fully depleted X-ray CCD and a pixelated CdTe detector, will provide spectra and images in the wide energy range from 0.5 keV to 80 keV. In the soft gamma-ray band upto ~1 MeV, a narrow field-of-view Compton gamma-ray telescope utilizing several tens of layers of thin Si or CdTe detector will provide precise spectra with much higher sensitivity than present instruments. The continuum sensitivity will reach several x 10-8 photons/s/keV/cm2 in the hard X-ray region and a few x 10-7 photons/s/keV/cm2 in the soft gamma-ray region.
The Wide-field X-ray Monitor (WXM) is one of the scientific
instruments carried on the High Energy Transient Explorer 2 (HETE-2)
satellite launched in October 2000. The WXM consists of three elements: (1) four identical Xe-filled one-dimensional position-sensitive proportional counters, two in the spacecraft X-direction and two in the Y-direction, (2) two sets of one-dimensional coded apertures orthogonally mounted above the counters in the X and Y-direction, and (3) the main electronics that processes analog signals from the counters. The WXM counters are sensitive to X-rays between 2 keV and 25 keV within a field-of-view of about 1.5 sr with a total detector area of about 350 cm2. The combination of the apertures and the counters provides GRB locations with accuracy ~10 arcmin. The counters and electronics are developed and fabricated by RIKEN, and the apertures and on-board software are designed and provided by Los Alamos National Laboratory. The WXM plays a major roll in the GRB localization and its spectroscopy in the energy range between 2 keV and 25 keV. During the first year of observations, a number of steady X-ray sources as well as high-energy transients were detected with the WXM. Observing Crab nebula and Sco X-1, we have calibrated the detector alignment between the WXM and the optical camera system with 2 arcmin accuracy. As of 29 July 2002, nineteen GRBs have been localized with the WXM in the 18 months of stable operations. Twelve of them were reported to the GCN within a delay of 10 hours, and 4 optical transients were identified by ground based telescopes. The energy response of the detectors has also been calibrated using the Crab spectrum. We report the in-orbit performance of the WXM instrument during the first 18 months.
A 100 MHz rf discharge excited slab carbon-dioxide laser with the near diffraction limited output power of 1.07 kW and the efficiency of 12.6% was studied. The size, including the laser head and the rf generator, is 1/4 of the fast axial flow laser. The self-excited rf generator with a cavity resonator made the laser simple and compact. To determine the rf excitation frequency, the discharge characteristics were studied at both frequencies of 40 MHz and 100 MHz.
Using a TE-CO2 laser, we could obtain a long-pulsed laser beam of low initial spike by controlling the discharge current by a pulse forming network and optimizing the gas composition, discharge length to resonator length ratio, and output mirror reflectivity. The maximum laser output was 1.1 J; the initial spike energy, 100 kW; the tail output, 56 kW; and the 16 (mu) sec (FWHM). The maximum repetition rate was 500 Hz. A new type of circuit with small pre-ionization current made it possible to operate the laser at a high repetition rate so as to prolong the laser life. When a 5-inch lens was used, the laser power density at the focal point was 1*108 W/cm2, making it possible to use the laser with an unusually high energy density without causing the breakdown of air insulation. In fact, we succeeded in fine- cutting a 0.5 mm thick alumina ceramic with the laser. It was found that unlike other working methods, the newly developed laser does not cause cracks in ceramic work pieces.
A high-speed wind tunnel, made by using a Ludwieg tube, has been successfully developed for a highly repetitive discharge-pumped excimer laser. This apparatus allows the gas flow of velocity approximately 204 m/s, pressure approximately 293 kPa, temperature approximately 254 K, and duration time approximately 48 ms. The rate constant for the recombination process of Xe+ + Cl- + Ne yields XeClX + Ne is found to increase to a maximum of 4.2 X 10-6 cm3/s at 180 K in a gas pressure of 294.2 kPa. The kinetic simulation of XeCl excimer laser using such a rate constant indicates the enhancement of the laser output in the lower gas temperatures.
The breakdown characteristics of a short-distance discharge gap in an atmosphere by TEA- CO2 laser have been studied to control the lightning artificially. It is efficient to enhance the probability of electrical breakdown induced if the focal point is set behind the discharge gap axis or near the negative high-voltage electrode. The length of the optical-breakdown plasma channel is elongated by using the micro-particles diffused in an atmosphere. Using 3 micrometers -diam. aluminum particles, the optical-breakdown threshold is lowered to 15 MW/cm2 compared to 0.5 GW/cm2 in the absence of the micro-particles.
KEYWORDS: Capacitors, Excimer lasers, Cadmium, Switching, Electrons, Solid state electronics, Energy efficiency, Electrodes, Solid state lasers, Gas lasers
A solid-state excitation circuit is demonstrated without any compression circuits. The new circuit contains the dc pre-charging capacitors and pulsed charging capacitors. The applied voltage between the electrode is the sum of the pre-charging voltage and the pulsed charging voltage. Therefore, the switching voltage is lowered when increasing the pre-charging voltage. In TEA-CO2 laser device, the stable discharge is excited by using only one thyristor device. In this circuit, the breakdown voltage is lower and output efficiency is higher than that obtained in the ordinary charge-transfer circuit. The high-repetition rate operation is tested up to 1 kpps. This circuit is also available for the excitation of KrF excimer laser.
Pre-charging of peaking capacitors has been tested on a high-repetition-rate transversely excited atmospheric CO2 laser. The peaking capacitors, connected to the discharge electrodes, were divided into two blocks in series. One part was pre-charged by a DC voltage source and another part was pulse-charged. An efficiency of over 6% was obtained by only 7 kV pulse voltage, and was higher than that obtained in a charge-transfer-type circuit. A high repetition rate operation up to 1 kHz was demonstrated.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.