Paper
16 June 1997 Thermal damage assessment of blood vessels in a hamster skin flap model by fluorescence measurement of a liposome-dye system
Serge R. Mordon, Thomas Desmettre, Jean-Marie Devoisselle, Sylvie Soulie-Begu
Author Affiliations +
Proceedings Volume 2975, Laser-Tissue Interaction VIII; (1997) https://doi.org/10.1117/12.275481
Event: BiOS '97, Part of Photonics West, 1997, San Jose, CA, United States
Abstract
The present study was undertaken to evaluate the feasibility of thermal damage assessment of blood vessels by using laser-induced release of liposome-encapsulated dye. Experiments were performed in a hamster skin flap model. Laser irradiation was achieved with a 300micrometers fiber connected to a 805nm diode laser after potentiation using a specific indocyanine green (ICG) formulation. Liposomes- encapsulated carboxyfluorescein were prepared by the sonication procedure. Carboxyfluorescein was loaded at high concentration in order to quench its fluorescence. The measurements were performed after i.v. injection of DSPC liposomes and lasted 40 minutes. Fluorescence emission was measured with an ultra high sensitivity intensified camera. Three different shapes of fluorescent spots were identified depending on target and energy deposition in tissue: (i) intravascular fluorescence, (ii) transient low fluorescence circular spot and (iii) persistent high intense fluorescence spot. These images are correlated with histological data. The advantages of this liposome-dye system are (1) direct measurements can be obtained, (2) several repeated readings can be made from one injection, (3) continuous monitoring of the fluorescence can be made, (4) temperature-sensitive range can be adapted using different liposomes compositions, (5) circulation times of several hours can be achieved using DSPC liposomes (6) the tissue microcirculation and the vessel macrocirculation can be investigated simultaneously, therefore changes in response to a treatment regimen and/or ICG formulations can be detected. One main constraint exists: the fluorescent dye encapsulated into the liposomes has to be carefully chosen in order to avoid any direct absorption by the dye itself. In conclusion, one of the most significant applications of this experimental technique is the evaluation of various degrees of tissue thermal damage. It could be possible to consider the application of this technique in ophthalmology and dermatology and possibly for the evaluation of burn injury.
© (1997) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Serge R. Mordon, Thomas Desmettre, Jean-Marie Devoisselle, and Sylvie Soulie-Begu "Thermal damage assessment of blood vessels in a hamster skin flap model by fluorescence measurement of a liposome-dye system", Proc. SPIE 2975, Laser-Tissue Interaction VIII, (16 June 1997); https://doi.org/10.1117/12.275481
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Luminescence

Blood vessels

Skin

Tissues

Absorption

Semiconductor lasers

Laser irradiation