Paper
10 November 2004 Short-wavelength ablation of solids: pulse duration and wavelength effects
Libor Juha, Michal Bittner, Dagmar Chvostova, Vit Letal, Josef Krasa, Zdenek Otcenasek, Michaela Kozlova, Jiri Polan, Ansgar R. Prag, Bedrich Rus, Michal Stupka, Jacek Krzywinski, Andrzej Andrejczuk, Jerzy B. Pelka, Ryszard H. Sobierajski, Leszek Ryc, Josef Feldhaus, Frederick P. Boody, Henryk Fiedorowicz, Andrzej Bartnik, Janusz Mikolajczyk, Rafal Rakowski, P. Kubat, Ladislav Pina, Michael E. Grisham, Georgiy O. Vaschenko, Carmen S. Menoni, Jorge J. G. Rocca
Author Affiliations +
Abstract
For conventional wavelength (UV-Vis-IR) lasers delivering radiation energy to the surface of materials, ablation thresholds, ablation (etch) rates, and the quality of ablated structures often differ dramatically between short (typically nanosecond) and ultrashort (typically femtosecond) pulses. Various short-wavelength (l < 100 nm) lasers emitting pulses with durations ranging from ~ 10 fs to ~ 1 ns have recently been put into a routine operation. This makes it possible to investigate how the ablation characteristics depend on the pulse duration in the XUV spectral region. 1.2-ns pulses of 46.9-nm radiation delivered from a capillary-discharge Ne-like Ar laser (Colorado State University, Fort Collins), focused by a spherical Sc/Si multilayer-coated mirror were used for an ablation of organic polymers and silicon. Various materials were irradiated with ellipsoidal-mirror-focused XUV radiation (λ = 86 nm, τ = 30-100 fs) generated by the free-electron laser (FEL) operated at the TESLA Test Facility (TTF1 FEL) in Hamburg. The beam of the Ne-like Zn XUV laser (λ = 21.2 nm, τ < 100 ps) driven by the Prague Asterix Laser System (PALS) was also successfully focused by a spherical Si/Mo multilayer-coated mirror to ablate various materials. Based on the results of the experiments, the etch rates for three different pulse durations are compared using the XUV-ABLATOR code to compensate for the wavelength difference. Comparing the values of etch rates calculated for short pulses with those measured for ultrashort pulses, we can study the influence of pulse duration on XUV ablation efficiency. Ablation efficiencies measured with short pulses at various wavelengths (i.e. 86/46.9/21.2 nm from the above-mentioned lasers and ~ 1 nm from the double stream gas-puff Xe plasma source driven by PALS) show that the wavelength influences the etch rate mainly through the different attenuation lengths.
© (2004) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE). Downloading of the abstract is permitted for personal use only.
Libor Juha, Michal Bittner, Dagmar Chvostova, Vit Letal, Josef Krasa, Zdenek Otcenasek, Michaela Kozlova, Jiri Polan, Ansgar R. Prag, Bedrich Rus, Michal Stupka, Jacek Krzywinski, Andrzej Andrejczuk, Jerzy B. Pelka, Ryszard H. Sobierajski, Leszek Ryc, Josef Feldhaus, Frederick P. Boody, Henryk Fiedorowicz, Andrzej Bartnik, Janusz Mikolajczyk, Rafal Rakowski, P. Kubat, Ladislav Pina, Michael E. Grisham, Georgiy O. Vaschenko, Carmen S. Menoni, and Jorge J. G. Rocca "Short-wavelength ablation of solids: pulse duration and wavelength effects", Proc. SPIE 5534, Fourth Generation X-Ray Sources and Optics II, (10 November 2004); https://doi.org/10.1117/12.560413
Lens.org Logo
CITATIONS
Cited by 2 scholarly publications.
Advertisement
Advertisement
RIGHTS & PERMISSIONS
Get copyright permission  Get copyright permission on Copyright Marketplace
KEYWORDS
Laser ablation

Polymethylmethacrylate

Extreme ultraviolet

Free electron lasers

Pulsed laser operation

Photons

X-rays

RELATED CONTENT

Free electron laser infrastructure in Europe 2012
Proceedings of SPIE (January 22 2013)
Application of laser plasma soft x ray and EUV sources...
Proceedings of SPIE (January 23 2007)
Comparing ablation induced by fs, ps, and ns XUV laser...
Proceedings of SPIE (September 20 2004)
X-ray laser-induced ablation of lead compounds
Proceedings of SPIE (May 18 2011)

Back to Top