Performing large-scale three-dimensional radiation dose reconstruction for patients requires a large amount of manual work. We present an image processing-based pipeline to automatically reconstruct radiation dose. The pipeline was designed for childhood cancer survivors that received abdominal radiotherapy with anterior-to-posterior and posterior-to-anterior field set-up. First, anatomical landmarks are automatically identified on two-dimensional radiographs. Second, these landmarks are used to derive parameters to emulate the geometry of the plan on a surrogate computed tomography. Finally, the plan is emulated and used as input for dose calculation. For qualitative evaluation, 100 cases of automatic and manual plan emulations were assessed by two experienced radiation dosimetrists in a blinded comparison. The two radiation dosimetrists approved 100%/100% and 92%/91% of the automatic/manual plan emulations, respectively. Similar approval rates of 100% and 94% hold when the automatic pipeline is applied on another 50 cases. Further, quantitative comparisons resulted in on average <5 mm difference in plan isocenter/borders, and <0.9 Gy in organ mean dose (prescribed dose: 14.4 Gy) calculated from the automatic and manual plan emulations. No statistically significant difference in terms of dose reconstruction accuracy was found for most organs at risk. Ultimately, our automatic pipeline results are of sufficient quality to enable effortless scaling of dose reconstruction data generation.
3D dose reconstruction for radiotherapy (RT) is the estimation of the 3D radiation dose distribution patients received during RT. Big dose reconstruction data is needed to accurately model the relationship between the dose and onset of adverse effects, to ultimately gain insights and improve today’s treatments. Dose reconstruction is often performed by emulating the original RT plan on a surrogate anatomy for dose estimation. This is especially essential for historically treated patients with long-term follow-up, as solely 2D radiographs were used for RT planning, and no 3D imaging was acquired for these patients. Performing dose reconstruction for a large group of patients requires a large amount of manual work, where the geometry of the original RT plan is emulated on the surrogate anatomy, by visually comparing the latter with the original 2D radiograph of the patient. This is a labor-intensive process that for practical use needs to be automated. This work presents an image-processing pipeline to automatically emulate plans on surrogate computational tomography (CT) scans. The pipeline was designed for childhood cancer survivors that historically received abdominal RT with anterior-to-posterior and posterior-to-anterior RT field set-up. First, anatomical landmarks are automatically identified on 2D radiographs. Next, these landmarks are used to derive parameters needed to finally emulate the plan on a surrogate CT. Validation was performed by an experienced RT planner, visually assessing 12 cases of automatic plan emulations. Automatic emulations were approved 11 out of 12 times. This work paves the way to effortless scaling of dose reconstruction data generation.
Access to the requested content is limited to institutions that have purchased or subscribe to SPIE eBooks.
You are receiving this notice because your organization may not have SPIE eBooks access.*
*Shibboleth/Open Athens users─please
sign in
to access your institution's subscriptions.
To obtain this item, you may purchase the complete book in print or electronic format on
SPIE.org.
INSTITUTIONAL Select your institution to access the SPIE Digital Library.
PERSONAL Sign in with your SPIE account to access your personal subscriptions or to use specific features such as save to my library, sign up for alerts, save searches, etc.